MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 27
MSO-0008P-012
Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet
1.MSO-0008P-012.pdf
(114 pages)
Specifications of MSO-0008P-012
Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
- Current page: 27 of 114
- Download datasheet (5Mb)
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
ORDERING INFORMATION
Single Shot
K2 Series
FEATURES
●
●
●
●
●
●
●
●
●
Operating Logic: Voltage is applied to the
timer at all times. Upon a momentary or
maintained closure of a normally open iso-
lated start switch, the output relay coil is
energized and the time delay starts. At the
end of the preset time delay, the relay coil
is de-energized and the timer is ready for a
new cycle.
Note: 1) Do not apply voltage or ground to the Start switch;
2) Switch leads should be shielded when running close to other
wires (Start switch supplied by customer)
LOGIC FUNCTION DIAGRAM
Input
Voltage
Start
Switch
Relay
Coil
100% functionally tested
Time delays to 10 seconds
Low cost
Compact size
Spade type base
Wide operating temperature range
Fiberglass reinforced circuit board
Polycarbonate, 94V-2 housing material
TIME RANGE
.1 to 10 sec.
Closed
Open
On
Off
On
Off
File #E59090
Single Shot Function
Timing
K2K-00010-661
120 VAC
SPECIFICATIONS
TIME DELAY
Adjustment: Knob, factory fixed on special
order (min. order required)
Range: 100 ms to 10 sec.
Repeatability: ±3% at constant temperature
Accuracy:
Maximum time +10%/-0%
Minimum time +0%/-50%
Reset Time: 200 ms max.
INPUT
Operating Voltage: 120 V AC ±10%
Start Switch Closure Time: 50 ms min.
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: Timers are protected by a 5
joule metal oxide varistor
Dielectric Breakdown: 1500 VAC RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: Spade (.187” x .020” terminal) type
plug-in base
Mounting: Socket mount, part number
MS0-00KUP-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C
TIME DELAY RELAYS
Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).
.70
Max.
Polarity Shown is
+
1
4
A
7
for D.C. Models
Case 6
Voltage
(3021-4)
1.531
Input
2.125
8
5
Start Switch
.25
(By Cust.)
3
6
-
9
B
1-17
Related parts for MSO-0008P-012
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Connector, D9 Female to D25 Male Null Modem Cable, 10 Foot
Manufacturer:
Quest Technology International, Inc.
Datasheet:
Part Number:
Description:
10ft D15hd Male To D15hd Female
Manufacturer:
Quest Technology International, Inc.
Datasheet:
Part Number:
Description:
10 Ft Mini Din 6 Female To Mini Din 6 Male
Manufacturer:
Quest Technology International, Inc.
Datasheet:
Part Number:
Description:
Cable Assembly, 10 ft D9 Male to D9 Male
Manufacturer:
Quest Technology International, Inc.
Part Number:
Description:
Relay; E-Mech; Timing; Multi-Function; DPDT; Cur-Rtg 10A; Ctrl-V 120AC; 11 Pin
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector; 120 VAC; 2 VA (Max.); 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Relay; E-Mech; Timing; Repeat Cycle; DPDT; Cur-Rtg 10A; Ctrl-V 120AC; 0.5 sec-999 min
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Relay; E-Mech; Timing; On Delay; DPDT; Cur-Rtg 10A; Ctrl-V 120AC; 8 Pin; 0.1-10 sec.
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Thermometer, Digital; -32 to degC; 1.5; + 1 degC; 12 to 28 VAC @ 50/60 Hz
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector; 120 VAC; 2 VA (Max.); 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector; 120 VAC; 2 VA (Max.); 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector; 120 VAC; 2 VA (Max.); 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector; 120 VAC; 2 VA (Max.); 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector Control; 120 VAC; 2 VA; 50/60 Hz; -40 to degC
Manufacturer:
NCC
Datasheet:
Part Number:
Description:
Dust Collector Control; 105 to 135 VAC; 10 VA; 50/60 Hz
Manufacturer:
NCC
Datasheet: