Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Delay On Break
Q3F Series
FEATURES
Operating Logic: Input voltage is applied
to the timer at all times. Upon closure of a
normally open isolated start switch, the load
energizes and remains energized as long as
the switch is closed. When the start switch
opens, the timing cycle starts. At the end
of the preset time delay, the load de-ener-
gizes and the timer is ready for a new timing
cycle. (Start switch supplied by customer.)
Note: 1) Do not apply voltage or ground to start switch; 2) remote
start switch leads should be shielded when running close to
other wires; 3) If the start switch is re-closed during timing, the
delay will reset and will not start timing until the start switch
is opened; 4) Remote potentiometer leads should be shielded
when running close to other wires; 5) The minimum time setting
on external resistor-adjustable time delay relays is obtained by
shorting together the external resistor terminals of the relay; 6)
The maximum time setting within tolerance limits is obtained by
using a 1 megohm resistor; 7) Timing values between the mini-
mum and maximum limits are linear with resistance within 10%;
8) Recommend 1/4 W minimum resistor be used.
ORDERING INFORMATION
Optional Potentiometer: Part Number ASY-0001M-450
Trigger time (start switch closure)
Reset time
Min. load
Max. leakage current
Voltage drop at 1 A
Power consumption
Peak 1 cycle surge
Protection
100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
180 to 3600 sec.
15 to 300 sec.
30 to 600 sec.
TIME RANGE
.05 to 1 sec.
.25 to 5 sec.
.5 to 10 sec.
3 to 60 sec.
.25 to 5 hrs.
.5 to 10 hrs.
File #E65038
Q3F-00001-326
Q3F-00005-326
Q3F-00010-326
Q3F-00060-326
Q3F-03600-326
Q3F-36000-326
12 VDC +10%
2.1 V max.
8.8j. MOV
200 ms
20 ms
10 uA
2.6 W
5 mA
4 A
(Retriggerable)
24 VAC/DC +10%
Q3F-00001-327
Q3F-00010-327
Q3F-00060-327
Q3F-00300-327
Q3F-00600-327
Q3F-03600-327
Q3F-18000-327
3.7 VA max.
3.2 V max.
8.8j. MOV
LOGIC FUNCTION DIAGRAM
Input
Voltage
SPECIFICATIONS
TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order required)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%-30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 240 VAC; 12 VDC; 24
VAC/DC ±10% (DC models have reverse polarity
protection. Unfiltered input voltage to them must
be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state normally open
Rating: 1 A steady state
Life: 100,000,000 cycles
PROTECTION
Transient Voltage: 30 joule metal oxide varistor,
see ratings below
Dielectric Breakdown: 3000 VAC, RMS, termi-
nals to mounting
Isolation Resistance: 100 megohms min.
between terminals and case
Start
Switch
Load
300 ms
20 ms
10 uA
5 mA
4 A
Closed
Open
On
Off
On
Off
Delay On Break Function
Q3F-00001-321
Q3F-00005-321
Q3F-00010-321
Q3F-00300-321
Q3F-03600-321
Q3F-18000-321
Q3F-36000-321
120 VAC +10%
4.3 VA max.
3.3 V max.
30j. MOV
200 ms
200 uA
20 ms
2 mA
20 A
Timing
Q3F-00005-325
Q3F-00010-325
Q3F-00300-325
Q3F-03600-325
Q3F-36000-325
240 VAC +10%
5.8 VA max.
3.3 V max.
30j. MOV
200 ms
300 uA
20 ms
2 mA
20 A
TIME DELAY RELAYS
MECHANICAL
Termination: .25” x .032” male fast-on
terminals
Mounting: Surface mount with one #8
screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.
Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).
Rt=
START
SWITCH
Tmaximum - Tminimum
Trequired - Tminimum
Rt
(3667-4)
LOAD
5
1
.25 X .032 MALE FAST-ON
2.00 SQ.
TERMINALS (7 PL.)
Polarity Shown is
4
C L
2
for DC Models
VOLTAGE
1.25
INPUT
x 1,000,000 ohms
.88
3
L C
.170
1-21
DIA.

Related parts for MSO-0008P-012