Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Repeat Cycle
Q6F Series
FEATURES
Operating Logic: Upon application of input
voltage, the OFF delay is initiated. At the
end of the OFF preset time, the load is acti-
vated and the ON delay starts. At the end of
the ON preset time, the load is deactivated
and a new cycle begins. The ON and OFF
cycles will continue to alternate until input
voltage is removed.
occurring first logic.
Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by short-
ing together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.
ORDERING INFORMATION
Optional Potentiometer: Part Number ASY-0001M-450
Consult factory for any special requirements not listed in catalog (minimum order requirement may apply).
OFF TIME FIRST LOGIC
ON TIME FIRST LOGIC
Trigger time (start switch closure)
Reset time
Min. load
Max. leakage current
Voltage drop at 1 A
Power consumption
Peak 1 cycle surge
Protection
This timer is available with ON time
100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
180 to 3600 sec.
15 to 300 sec.
30 to 600 sec.
30 to 600 sec.
TIME RANGE
.05 to 1 sec.
.25 to 5 sec.
.5 to 10 sec.
3 to 60 sec.
3 to 60 sec.
.25 to 5 hrs.
.5 to 10 hrs.
File #E65038
12 VAC/DC +10%
Q6F-00001-326
Q6F-00005-326
Q6F-00010-326
Q6F-00060-326
Q6F-00600-326
Q6F-18000-326
Q6F-00060-336
2.6 W max.
rev. voltage
2.1 V max.
500 ms
500 ms
100 uA
5 mA
4 A
24 VAC/DC +10%
Q6F-00001-327
Q6F-00005-327
Q6F-00010-327
Q6F-00060-327
Q6F-00300-327
3.7 VA max.
3.2 V max.
8.8j. MOV
LOGIC FUNCTION DIAGRAM
"Off" Time
First
"On" Time
First
SPECIFICATIONS
TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order requirement)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (.25% typical) at
constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%, -30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 240 VAC; 12 VDC; 24
VAC/DC ±10%; (DC models have reverse polarity
protection. Unfiltered input voltage to them must
be full-wave rectified)
Frequency: 50/60 Hz
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
OUTPUT
Type: Solid state, normally open
Rating: 1 A steady state
Life: 100,000,000 operations
500 ms
500 ms
100 uA
5 mA
Input
Voltage
4 A
Load
Load
On
Off
On
Off
On
Off
Q6F-00001-321
Q6F-00005-321
Q6F-00010-321
Q6F-00060-321
Q6F-00300-321
Q6F-00600-321
Q6F-03600-321
Q6F-00060-331
Q6F-00600-331
120 VAC +10%
4.3 VA max.
3.3 V max.
30j. MOV
500 ms
500 ms
100 uA
2 mA
20 A
Adj. "On" Delay
Adj. "Off" Delay
Adj. "Off" Delay
Adj. "On" Delay
Q6F-00001-325
Q6F-00005-325
Q6F-00010-325
Q6F-00060-325
Q6F-00300-325
Q6F-00600-325
Q6F-18000-325
Q6F-36000-325
240 VAC +10%
5.8 VA max.
3.3 V max.
30j. MOV
500 ms
500 ms
100 uA
2 mA
20 A
TIME DELAY RELAYS
PROTECTION
Transient Voltage: Metal oxide varistor
see rating below
Dielectric Breakdown: 3000 VAC,
RMS, terminals to mounting
Insulation Resistance: 100 megohms
min. between terminals and case
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.
Rt=
Off Time
Rt
Tmaximum - Tminimum
Trequired - Tminimum
Rt
(3667-8)
LOAD
5
1
.25 X .032 MALE FAST-ON
2.00 SQ.
TERMINALS (7 PL.)
Polarity Shown is
On Time
4
C L
2
for DC Models
VOLTAGE
1.25
INPUT
.88
x 1,000,000 ohms
3
L C
.170
DIA.
1-29