Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
SPECIFICATIONS
TIME DELAY
OFF-Delay Time: Adjustable from 100 sec. +0%,
-50% to 1000 sec. +10%, -0%. OFF Delay Time
can be disabled
ON-Time: Adjustable from 50 to 500 ms
OFF-Time:
Range A: adjustable from 1.5 to 30 seconds
Range B: adjustable from 8.5 to 180 seconds
Repeatability: ±3% over temperature and volt-
age ranges
INPUT
Operating Voltage: 105 to 135 VAC
Frequency: 50/60 Hz
Power Consumption: 5 VA max.
OUTPUT
Type: Solid state switch (triac)
Switch Rating: 200 VA max. per output, 1.8 VAC
RMS max.; ON state voltage drop 4 mA max.;
OFF state leakage current at 120 VAC
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 A fuse
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 85°C
ORDERING INFORMATION
AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a con-
tinuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.
NEMA 4 Box
Pilot Lamp
On/Off Switch
PROGRAMMABLE NO.
OF OUTPUTS
ACCESSORY
1 to 3
NEMA 4 Rated with Legend Plate
NEMA 4 Rated Red Light
8.5 to 180 sec.
1.5 to 30 sec.
DIMENSIONS
10” x 8” x 4”
OFF TIME
(SUPPLIED BY CUST.)
PRESSURE SWITCH
Do not use Slow Blow
or larger size. Failure
PRESSURE
SWITCH
to comply will void
the Warranty
L1
L2
3 AMP
8.5
75
OFF TIME
sec.
100
POWER
Line voltage must be
105 to 135 volts.In
grounded system
connect neutral of
line to L2.
ON
L1
LINE
125
180
150
L2
1
ASL-00RED-NEMA 4
2
.5
BOX-A1008-CHNF
ON TIME
SOL.
COM
MSW-0DPST-011
DNC-T2003-A10
DNC-T2003-B10
PART NUMBER
PART NUMBER
sec.
s
3
1
5
4
8.750
400
250
National Controls
Corporation
100
2
OFF DELAY
(200 VA/OUTPUT MAX)
550
DUST COLLECTOR CONTROLS
sec.
3
8.250
700
1000
OUTPUTS
850
4
ENABLE
DISABLE
Line Voltage:105to135 VAC,50-60H
PROGRAM CONTROL
PROGRAM WIRE
5
6
2
3
7
ATTACH
4
OUTPUT USED
5
8
6
TO
7
9
LAST
z
8
10
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-