MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 84

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
4-12
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
DUSTRONIX
Model DNC-PS700-A10
FEATURES
Programmable Parameters:
The DUSTRONIX Pressure Differential Meter is
designed to interface with NCC dust collector
controls as well as other controllers. This meter
is capable of measuring differential pressure and
displaying that value in both analog bargraph
and digital displays. Both Low/High Cleaning and
Low/High Alarm setpoints can be programmed
with relay outputs. The Cleaning relay will ener-
gize when the measured pressure exceeds the
High Cleaning Setpoint, and will de-energize
when the pressure goes below the Low Cleaning
Setpoint. The Alarm relay will energize whenever
the measured pressure exceeds the High or Low
Alarm Setpoint.
will accept either a 0 to 10” w.c. pressure input
or a 4 to 20 mA input. A 4 to 20 mA output loop
is provided when the internal pressure sensor
is used. A 3-digit security code is also provided
to prevent unauthorized changes. The meter is
equipped with non-volatile memory which will
store all operating parameters when power is
removed.
The DUSTRONIX Pressure Differential Meter
51 element tri-color LED meter move-
ment
 P control relay output: programmable,
normally open or normally closed
 P alarm relay output: programmable,
normally open or normally closed
Cleaning status LED
Alarm status LED
0-10” w.c.  P range
Source or sink 4 to 20 mA  P output
1/4 DIN panel mountable
NEMA 4 compatible
3-digit, 7-segment alpha-numeric
display
Removable finger-safe terminations
Replaces most popular  P switches/
gauges
Non-volatile memory
User selectable program access code
Universal input voltage
Alarm Low/High setpoints
Cleaning Low/High setpoints
Alarm relay (normally open or normally
closed)
Cleaning relay (normally open or nor-
mally closed)
Units of measure (inches, w.c. or kPa)
Security code (user settable)
 P offset compensation capability
DUST COLLECTOR CONTROLS
Pressure Differential Meter
Operating Logic: The DUSTRONIX Pressure
Differential Meter is shipped with factory
default settings (see details below). A pres-
sure or 4 to 20 mA input needs to be con-
nected, outputs wired as required, and
power applied to have a functioning system.
Program parameters can now be set for the
specific application.
SPECIFICATIONS
FACTORY DEFAULT SETTINGS
Low Alarm Setpoint = 1.0
High Alarm Setpoint = 8.0
Low Cleaning Setpoint = 2.0
High Cleaning Setpoint = 4.0
Alarm Relay = Ano
Cleaning Relay = Cno
Units = IN
Security Code = 0.0.0.
INPUTS
Voltage: 100-240 VAC, 50/60 Hz
Power Consumption: 5 VA max. at 240 VAC
OUTPUTS
Alarm Output Type: Form A relay contact, pro-
grammable normally open or normally closed
Alarm Output Rating: 5 A at 240 VAC/30 VDC
Control Output Type: Form-A relay contact, pro-
grammable normally open or normally closed
Control Output Rating: 5 A at 240 VAC/30 VDC
CURRENT LOOP
Type: 4 to 20 mA current loop, switch selectable
sink/source, represents 0 to 10” w.c.  pressure
Accuracy: ±0.3 mA of displayed pressure
Measurement: Current of 4 to 20 mA or pressure
of 0 to 10 in. water
MECHANICAL
Enclosure: 1/4 DIN meter face
Material: 304 stainless steel
Electrical Terminations: Removable screw termi-
nals, 14-22 AWG
Pressure Terminations: Removable 0.125” hose-
barb type fittings
PRESSURE SENSOR
Type: Silicon piezoresistive transducer
Measurement Range: 0.0 to 10.0 in. water
(0-2.5 KPa)
ORDERING INFORMATION
NEMA 4 enclosure for DNC-PS700-010
INPUT VOLTAGE
100 to 240 VAC
ACCESSORY
DNC-PS700-010
PART NUMBER
8” x 6” x 3.5”
DIMENSIONS
separately as an accessory
Controls, as well as other
to NCC Dust Collector
may be purchased
controllers
The PS700
BOX-A0806-CHNF
PART NUMBER