MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 85

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Accuracy: ±2% of full scale at 77°F (25°C); ±5%
of full scale over temperature and voltage range
Maximum Continuous Pressure: 10 psi
DISPLAYS
Units: Programmable for in. water or kPa
Bargraph Display: 51 element tri-color LED ana-
log differential pressure bargraph
Green = Differential pressure
Yellow = Cleaning setpoints
Red = Alarm setpoints
Digital Display: 3-digit, 7-segment differential
pressure display, 0.3 in. tall
N a
t i
o
n
l a
C
o
n t
SHOWN WITH ELECTRICAL
.2
r l
o
CONNECTOR REMOVED
BOTTOM VIEW
s
.4
C
o
r p. .
.6
.8
3.500
Digital Meter
1.0
1.2
1.4
1.6
1.8
2.0
2.2
OR EQUIVALENT
PHOENIX #17-57-30-7
8 POS. CONNECTOR
2.4
OR EQUIVALENT
CONNECTOR
MOLEX #398600308
8 POS.
REMOVEABLE
120/240VAC/30VDC
PRESSURE
60185
TOP VIEW
CORPORATION
MAX.
METER
(2 PLACES)
REMOVABLE
MOUNTING BRACKET
SHOWN FOR REFERENCE
RIGHT SIDE VIEW
DNC-PS700-A10
Range: 00.0 to 10.0 in. (00.0 to 02.5 KPa), shows
“OPn” with no sensor connected or with vacuum
applied
Discrete LED Indicators:
Cleaning = Green
Alarm = Red / Yellow
ENVIRONMENTAL
Operating Temperature Range: 32° to 150°F (0°
to 65°C)
Protection: Conformal coating on PCB for
humidity and vibration
IL.
OPERATING
RESISTANCE
5VA
CHICAGO,
BY
WATER
PRESSURE
CALL
MANUFACTURED
(800)323-2593
OUTPUT
Hz
SERVICE
AMPS
CONTROLS
50/60
OF
WATER
WEST
INCHES
INCHES
LOOP
DIFFERENTIAL
NO.
5
S/N:
SOURCE
VAC
OUTPUT:
FOR
DR.
MODEL
MAX
90-265
OF
NATIONAL
0-10
0-10
WESTERN
INCHES
3.298
3.111
CURRENT
OHMS
RATINGS:
PRESSURE:
OUTPUT:
CONTROL/ALARM
VOLTAGE:
0-10
1725
450
E165149
US
OUTPUT
MA
RANGE:
R
INPUT
INPUT
4-20
C
BLACK INK
SCREENING
RECOMMENDED PANEL CUT-OUT
DUST COLLECTOR CONTROLS
N a
t i
o
n
l a
C
o
n t
.2
r l
o
s
.4
C
FRONT VIEW
o
r p. .
.6
.8
Digital Meter
1.0
4.000
3.625
1.2
1.4
+0.000
-0.025
1.6
1.8
2.0
2.2
2.4
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-
nents that could be further damaged. For service, call
us directly: 800-323-2593.
OVERLAY
POLYESTER
FOR REMOVEABLE 8 POSITION CONNECTOR
ELECTRICAL CONNECTIONS
OUTPUT CONTACTS
ALARM RELAY
OUTPUT CONTACTS
CLEANING RELAY
MOUNTING BRACKET
50/60 Hz
85 - 240 VAC
4 - 20 mA
OUTPUT
ASSEMBLY
}
}
}
}
L2
L1
+
-
4-13

Related parts for MSO-0008P-012