MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 87

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
RS232 Port:
Programming Logic: The controller as sup-
plied from the factory will require user con-
figuration. Upon application of power the
display will indicate SETUP. The operator
must then configure the various operating
parameters using the six key keyboard of
the controller before normal cleaning opera-
tion can begin. The programmable param-
eters for Standard Operation as displayed
are:
Remote Terminal: An ANSI type ter-
minal is required for remote monitor-
ing and programming of the controller.
Connection to the controller is made via
the RS232 port (9 pin D-Sub connec-
tor). All the functions and display status
accessible from the controller are avail-
able through the ANSI terminal.
Remote I/O Interface: The 2310/2320
controllers are capable of communication
with the DNC-T2300-I/O board via the
RS232 port. This allows the user to moni-
tor up to three 4-20 mA analog inputs,
three contact closure type inputs, and
one Type J thermocouple. The I/O mod-
ule is programmed via the 2310/2320
keypad and can be user defined to set
alarm points from remote sensors of
parameters such as emission, air flow,
pressure, broken bags, fan motor current,
etc. Refer to the data sheet for the DNC-
T2300-I/O for additional information.
OUTPUT
Auto Configuration: will automatically
sense the solenoids connected to the
outputs and will only pulse those outputs
during cleaning cycles.
Manual Configuration: the controller will
pulse each output until the last output
programmed and then recycle to output
#1.
LAST: the number of the last output
used.
LO DP: Low Pressure Setpoint, the pres-
sure at which the controller will stop its
cleaning cycle.
HI DP: High Pressure Setpoint, the pres-
sure at which the controller will start its
cleaning cycle.
ON: Output Solenoid On Time.
OFF: Off Delay Time Between Output
Solenoid Activation.
ALARM: High Differential Pressure Alarm
Set-point, the pressure at which the con-
troller will close its alarm contacts.
For enhanced timer programming informa-
tion, see IDC Programming Tree on page
4-6.
Additional Features: The 2310/2320 con-
trollers also provide:
L1
4 - 20 mA Output Loop: This output will
provide a continuous reading from 4 -20
mA corresponding to the sensed differen-
tial pressure range of 0” to 15” water col-
umn. This is a standard feature.
24 Hour Time/Day/Month Clock: The
clock feature will allow a daily automat-
ic turn on and turn off command to be
implemented by the controller. It can be
programmed to start and stop the clean-
ing cycles for up to seven events per
week. This is an optional feature found on
the B-series models.
INPUT VOLTAGE 120 VAC
L2
L1
National Controls
Corporatio n
INPUT VOLTAGE 120 VAC
L2
DIFFERENTIAL PRESSURE ( P)
INTELLIGENT DUST CONTROL
1725 Western Dr .
West Chicago, IL. 6018 5
SOL
COM
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA
S/N:
INCHES OF WATER
1
National Controls
Corporatio n
Date Code:
2
Model DNC-T2310-010
3
EXPANDED MODE WIRING DIAGRAM FOR DNC-T2310-*10
D
4
-T2320-
PRESSURE
CONNECTIONS:
HI SIDE
LOW SIDE
OUTPUTS
5
ITEM
6
EXPANDED MODE WIRING DIAGRAM FOR DNC-T2320-*10
CONNECTOR
VALUE
RS232
7
OUTPUT
ALARM
ALARM
INPUT
OUTPUT
CANCEL
8
ALAR M
STEP
BYPASS
INPUT
9
10
DUST COLLECTOR CONTROLS
120 VAC Coi l
SPST-NO
Relay
AUX INPUT
COI L
N O . .
#4
AUX OUTPUT
#4
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-
nents that could be further damaged. For service, call
us directly: 800-323-2593.
PRESSURE SWITCH INPUT
L1
L2
(DNC-T2010 model shown)
Dust Collector Controller
C
DNC-T2032 Series
DNC-T2003 Through
DNC-T2010 MODEL SHOWN
1
COLLECTOR CONTROLLER
L1 L2
DNC SERIES DUST
2
(EXCEPT T2310)
PRESSURE SWITCH
3
C
S
4
1
LAST SOLENOID
Last solenoid
2
5
3
6
4
5
7
S
6
8
7 8
9
9
10
10
4-15