BE650G American Power Conversion (APC), BE650G Datasheet - Page 7

no-image

BE650G

Manufacturer Part Number
BE650G
Description
APC BACK-UPS ES 8 Outlet 650VA 120V
Manufacturer
American Power Conversion (APC)
Type
Home/Office, Networkr
Datasheet

Specifications of BE650G

Brand/series
Back-UPS®
Capacity
650 VA
Color
Charcoal
Communication
RJ45, USB
Dimensions
89mmH×320mmW×178mmD
Input Type
NEMA 5-15P
Length, Cord
1.83 m
Output Type
(4) NEMA 5-15R
Power, Rating
390 W
Time, Backup
3.8 min.
Voltage, Output
120 V
Voltage, Supply
390/650 W/VA
Weight
6.5 kg
Troubleshooting
Back-UPS ES will not turn on.
No power available at the Surge Protection
outlets.
Back-UPS is on, but Replace Battery indicator
flashes, and unit emits a constant tone.
Connected equipment loses power.
The Power On indicator is lit and the Back-
UPS ES beeps four times every 30 seconds.
The Power On indicator flashes and the Back-
UPS beeps twice per second at the same time.
Building Wiring Fault indicator is lit.
Inadequate runtime.
No phone/fax/DSL/cable or network signal
from the Back-UPS.
Internet connection lost during power outage.
Internet connection lost during power outage.
Specifications
Input
Output
Protection and
Filter
Battery
Physical
Safety and
Regulatory
Model
Problem
Voltage
Frequency
Brownout Transfer
Over-voltage Transfer
UPS Capacity (4 outlets)
Total Amperage (8 outlets)
Voltage - On Battery
Frequency - On Battery
Transfer Time
AC Surge Protection
Phone/fax/DSL Surge
Protection
Cable/CATV/DSS Surge
Protection
Network Surge Protection
EMI/RFI Filter
AC Input
Type
Average Life
Net Weight
Size
Operating Temperature
Storage Temperature
Operating Relative Humidity
Operating Elevation
Safety Approvals
EMC Compliance
Use the table below to solve minor Back-UPS ES installation or operation problems. Consult APC Online Technical Support or call APC
Technical Support for assistance with problems that cannot be resolved using the table below:
3 - 5 years depending on the number of discharge cycles
Notice: This device complies with part 68 and part 15 of
the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any
interference received, including interference that may
cause undesired operation.
“On the bottom of this equipment is a label that contains,
among other information, the FCC registration number
and ringer equivalence number (REN) for this equipment.
If requested, this information must be provided to the
telephone company.”
The battery is disconnected, and either power is unavailable
at the wall outlet, or utility power is having a “brownout” or
an “over voltage” condition.
Surge Protection outlets were overloaded.
Utility power not available at the wall outlet.
Battery is disconnected.
Equipment is connected to the “Surge Protection” outlets.
The Back-UPS ES is overloaded.
PowerChute Personal Edition software has performed a
shutdown due to a power failure.
The Back-UPS ES has exhausted its available battery
power.
Connected equipment does not accept the step-
approximated sine waveform from the Back-UPS ES.
The Back-UPS ES may require service.
The Back-UPS ES is On Battery.
Battery capacity is low (about 2 minutes of use remaining).
Your building wiring presents a shock hazard. Using the
Back-UPS with this condition will void the warranty.
The battery is not fully charged.
Battery is near the end of useful life.
Data line from the ISP or wall outlet is connected to the
wrong jack on the Back-UPS.
Modem lost AC power.
Modem has lost AC Power.
Probable Cause
TUV C-US certified; UL 1778 standard per CSA
115 Vrms + 8% (step-approximated sine wave)
standard C22.2 No. 107.1, FCC part 68 &
FCC part 15 Class B, NOM certified
Sealed, maintenance-free lead acid
3.54" (H) x 12.6" (W) x 6.97" (D)
12 Amps (including UPS output)
and environmental temperature
+5
6 ms typical, 10 ms maximum
+32
0 to 10,000 ft (0 to 3,000m)
50 - 60 Hz (auto-sensing)
Resettable circuit breaker
0 to 95% non-condensing
o
10/100Base-T Ethernet
One Coax Input/Output
F to 113
o
(9.0 x 32.0 x 17.7 cm)
Full time, 375 joules
F to 104
Single line (2-wire)
120 Vrms nominal
50 - 60 Hz + 1 Hz
139 Vrms, typical
14.3 lb. (6.5 Kg.)
88 Vrms, typical
650 VA / 390 W
Full time
o
BE650G
F (-15
o
F (0
o
o
C to 40
C to 45
o
o
C)
C)
Order Replacement Battery
Warranty
Service
Plug the modem’s AC power cord into one of the “Battery Back-up Plus Surge Protec-
tion outlets”.
Replace with an APC qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). The replacement battery part number for
this Back-UPS is: RBC17.
The standard warranty is 3 years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with APC Technical Support. APC
will ship the replacement unit once the defective unit is received by the repair
department or cross-ship upon the provision of a valid credit card number. The
customer pays for shipping to APC, and APC pays ground freight transportation costs
back to the customer.
Please DO NOT RETURN Back-UPS ES to the place of purchase under any
circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is
not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical
Support.
Connect the battery (see Connect Battery) and ensure power is available at the wall
outlet. If battery is connected and power is unavailable, the unit can be “cold
started” (operated on battery power) by holding the power button down until two
beeps are heard.
Reduce the amount of equipment plugged into the Surge Protection outlets.
Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
controlling the outlet (if any) is in the ON position.
Connect the battery (see Connect Battery diagram).
Ensure the equipment you want to stay powered during a power failure is plugged
into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge
Protection Only” outlets.
Make sure the equipment plugged into the outlets of the unit are not overloading its
capacity. Try removing some of the equipment and see if the problem continues.
The Back-UPS ES is operating normally.
The Back-UPS ES can only operate on battery power for a limited amount of time.
The unit will eventually turn off when the available battery power has been used.
Allow the unit to recharge for 16 hours before expecting maximum runtime.
The output waveform is designed for computers and computer-related equipment. It
is not designed for use with motor-type equipment.
Contact APC Technical Support for further troubleshooting.
The Back-UPS ES is operating normally, and using battery power. Once On Battery,
you may want to save your current work, power down your equipment, and turn the
unit OFF. Once normal power is restored, you may turn the unit back ON, and power
your equipment.
The Back-UPS ES is about to shut off due to a low battery charge condition! When
the unit beeps twice every second, the battery has about 2 minutes of power
remaining. Immediately power down your computer ,and turn the unit OFF. When
normal power returns, the unit will recharge the battery.
Call a qualified electrician for service.
Allow the unit to charge by leaving it plugged into the wall at least 16 hours.
As a battery ages, the amount of runtime available will decrease. You can replace
the battery by ordering one at www.apc.com. Batteries also age prematurely if the
Back-UPS ES is placed near excessive heat.
Make sure the data line from the wall outlet is connected to the jack labeled “Wall
Outlet”, or “Cable In” (Cable/DSS/CATV).
Plug the AC power cord of the modem into one of the four “Battery Back-up plus
Surge Protection” outlets.
Solution