940C10W1K-F Cornell-Dubilier, 940C10W1K-F Datasheet

no-image

940C10W1K-F

Manufacturer Part Number
940C10W1K-F
Description
CAPACITOR, POLYPROPYLENE FILM, HIGH DV/DT, 1000VDC, 1UF
Manufacturer
Cornell-Dubilier
Datasheet

Specifications of 940C10W1K-F

Brand/series
940C Series
Capacitance
1.00 μF
Material, Element
Polypropylene Metallized
Termination
Axial
Tolerance
±10%
Voltage, Rating
1000 VDC
Capacitance Range
0.01 to 4.7 μF
Voltage Range
600 to 3000 VDC (275 to 750 VAC, 60 Hz)
Operating Temperature
–55°C to 105°C
Lead Free Status / Rohs Status
RoHS Compliant part
Cornell Dubilier
Type 940C through 943C
ACCELERATED TESTS
Accelerated Life
Performance
Accelerated Pulse Testing
Performance
Maximum allowable current in Amperes at 70°C
Operating Temperature
Capacitance Tolerance
Dissipation Factor
Dielectric Withstand
Insulation Resistance
Equivalent Series Resistance (ESR)
Equivalent Series Inductance (ESL)
dV/dt
Rated Current, Ipk, Irms
Capacitance Temperature Coefficient
Service Life
Electrical Characteristics
1605 E. Rodney French Blvd.
Typical Characteristics
New Bedford, MA 02740
Power Film Capacitors
1.25 x rated DC voltage at 85°C
per IEC-384
for 2,000 Hours
<3% capacitance change
ESR <125% of initial reading
IR >50% of initial limit
<3% in capacitance change
<.003 increase in df from initial value
-55°C to +105°C *
* Full rated voltage at 85°C-Derate linearly to 50% rated voltage at 105°C
±10% standard tolerance
<0.1% at 1 kHz, 25°C
1.6 x rated voltage for 60 seconds
>100,000 megohms x µF at 100 Vdc
measured after 2 minutes
See data tables for values
See data tables for values
See data tables for values
See data tables for values
-200 ppm/°C ±100 ppm
30,000 hours @ rated Vac, 70°C
60,000 hours @ rated Vdc, 70°C
Phone: (508)996-8564
Fax: (508)996-3830 www.cde.com

Related parts for 940C10W1K-F

940C10W1K-F Summary of contents

Page 1

... Performance Accelerated Pulse Testing Performance • Cornell Dubilier 1605 E. Rodney French Blvd. Power Film Capacitors -55°C to +105° Full rated voltage at 85°C-Derate linearly to 50% rated voltage at 105°C ±10% standard tolerance <0. kHz, 25°C 1.6 x rated voltage for 60 seconds >100,000 megohms x µF at 100 Vdc ...