CA2KN40G7 TELEMECANIQUE, CA2KN40G7 Datasheet - Page 5

no-image

CA2KN40G7

Manufacturer Part Number
CA2KN40G7
Description
RELAY, INDUSTRIAL, MINIATURE, NEMA A600/Q600, 120VAC CONTROL, 4 NO CONTACTS
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of CA2KN40G7

Contact Form
4PST-NO
Current, Rating
10 A
Function
Contactor
Relay Type
Electro Mechanical
Standards
IEC Approved
Voltage, Rating
600 VAC
Dimensions (l × W × H)
58 × 45 × 57 mm
Approvals
UL, CSA, DEMKO, NEMKO, SEMKO, FI
04/01
LA6DK
LADT
LAD4
Time Delay Auxiliary Contact Blocks
Mechanical Latch Blocks
Coil Suppressor Modules
Number and
Type of Contacts
1 N/C and 1 N/O
(Lockout Cover, See page 7)
Unlatching Control
Manual or electrical
These modules clip onto the right hand side of the control relay and the electrical connection is instantly made. Adding an input module is still possible.
RC Circuits (Resistor-Capacitor)
- Effective protection for circuits highly sensitive to “high frequency” interference.
- Voltage limited to 3 Uc maximum and oscillating frequency limited to 400 Hz maximum.
- Slight increase in drop-out time (1.2 to 2 times the normal time).
For Mounting On:
CAD (Vac)
Varistors (Peak Limiting)
- Protection provided by limiting the transient voltage value to 2 Uc maximum.
- Maximum reduction of transient voltage peaks.
- Slight increase in drop-out time (1.1 to 1.5 times the normal time).
CAD (Vac)
Bidirectional Peak Limiting Diode
- Protection provided by limiting the transient voltage value to 2 Uc maximum.
- Maximum reduction of transient voltage peaks.
CAD (Vac)
Vac and Vdc
Code
With extended scale from 0.1 to 0.6 s.
With switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O contact.
Power should not be simultaneously applied or maintained to the mechanical latching block and the CAD relay. The duration of the control signal to
the mechanical latching block and the CAD relay should be
Standard coil voltage codes.
Maximum Number
per Device
Front Mounting
1
Operational Voltage
24 to 48 Vac
110 to 240 Vac
24 to 48 Vac
50 to 127 Vac
110 to 250 Vac
24 Vac
72 Vac
B
24
©
2001 Schneider Electric All Rights Reserved
Maximum Number per
Device
Front mounting
1
32/36
C
Time Delay
Type
On-Delay
Off-Delay
42/48
E
100 ms.
60/72
EN
Termination
Type
Screw Clamp
Spring Terminal
Screw Clamp
Spring Terminal
Catalog Number
LA6DK10
LAD6K10
100
K
Range
0.1 to 3 sec.
0.1 to 30 sec.
10 to 180 sec.
1 to 30 sec.
0.1 to 3 sec.
0.1 to 30 sec.
10 to 180 sec.
1 to 30 sec.
0.1 to 3 sec.
0.1 to 30 sec.
10 to 180 sec.
0.1 to 3 sec.
0.1 to 30 sec.
10 to 180 sec.
TeSys Ordering Information
Catalog Number
LAD4RCE
LAD4RCU
LAD4VE
LAD4VG
LAD4VU
LAD4TB
LAD4TS
110/127
F
Catalog
Number
LADT0
LADT2
LADT4
LADS2
LADT03
LADT23
LADT43
LADS23
LADR0
LADR2
LADR4
LADR03
LADR23
LADR43
220/240
M
Weight lb. (kg)
0.15 (0.070)
0.15 (0.070)
Weight lb. (kg)
0.03 (0.012)
0.03 (0.012)
0.03 (0.012)
0.03 (0.012)
0.03 (0.012)
0.03 (0.012)
0.03 (0.012)
256/277
U
Weight lb. (kg)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
0.13 (0.060)
380/415
Q
5

Related parts for CA2KN40G7