LC1K0910G7 TELEMECANIQUE, LC1K0910G7 Datasheet - Page 10

no-image

LC1K0910G7

Manufacturer Part Number
LC1K0910G7
Description
CONTACTOR, MINIATURE, UP TO 5 HP AT 575/600 VAC 3-PH., 120 VAC CTRL., 1 NO AUX.
Manufacturer
TELEMECANIQUE
Type
General Dutyr
Datasheet

Specifications of LC1K0910G7

Contact Form
1 NO
Current, Rating
9 A
Current, Rating Max
9
Function
Contactor
Horse Power Rating
5
Primary Type
Contactor
Relay Type
Electro Mechanical
Standards
IEC Approved
Voltage, Rating
600 VAC
Voltage, Supply
600 VAC
Dimensions (l × W × H, Mm)
58 × 45 × 57
Tesys Application Data
10
Type
Rated Insulation Voltage (Ui)
Rated Impulse Withstand Voltage (Uimp)
Separation of Electrical Circuits
Conforming to Standards
Approvals
Protective Treatment
Degree of Protection
Ambient Air Temperature Around the Device
Maximum Operating Altitude
Operating Positions
Shock Resistance
Half sine wave for 11ms
Vibration Resistance
5 to 300 Hz
Connection to Screw Clamp Terminals
Connection to Spring Terminals
In the least favorable direction, without change of contact state, with coil supplied at Uc.
TeSys Application Data
Without derating,
in the following
positions:
Conforming to IEC 60947-1-1
Overvoltage category III
and degree of pollution 3
Conforming to UL, CSA
Conforming to IEC 60947-1-1
To IEC 536 and VDE 0106
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation, conforming to IEC 255 (80 to 110% UC)
For operation at Uc
Without derating
Control relay open
Control relay closed
Control relay open
Control relay closed
Stranded wire
without cable end
Stranded wire
without cable end
Solid wire
without cable end
Tightening torque
1 or 2 stranded or solid without cable end
1 conductor
2 conductors
1 conductor
2 conductors
1 conductor
2 conductors
©
2001 Schneider Electric All Rights Reserved
V
V
kV
°F (°C)
°F (°C)
°F (°C)
ft (m)
AWG
(mm
AWG
(mm
AWG
(mm
AWG
(mm
AWG
(mm
AWG
(mm
lb-in
(N m)
AWG
(mm
2
2
2
2
2
2
2
)
)
)
)
)
)
)
CAD (Vac)
690
600
6
Reinforced insulation up to 400 V
IEC 60947-1-1, N-F C 63-140, VDE 0660, BS 4794.
EN 60947-5-15
UL
CSA
CE
“TH” (Tropical Finish) See page 23 for details.
Front face protected against direct finger contact IP 2X
- 76 to 176 (- 60 to + 80)
23 to 140 (- 5 to + 60)
- 40 to 158 (- 40 to + 70)
9843 (3000)
10 gn
15 gn
2 gn
4 gn
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 14 (1 to 2.5)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
15 (1.7)
# 18 to # 14 (1 to 2.5)
File: E164353
File: LR43364
CCN: NKCR
Guide: 3211 03
CAD (Vdc)
690
600
6
- 76 to 176 (- 60 to + 80)
23 to 140 (- 5 to + 60)
- 40 to 158 (- 40 to + 70)
9843 (3000)
10 gn
15 gn
2 gn
4 gn
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 14 (1 to 2.5)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
15 (1.7)
# 18 to # 14 (1 to 2.5)
CAD (Vdc)
Low Consumption
690
600
6
Protection against direct
finger contact
- 76 to 176 (- 60 to + 80)
23 to 140 (- 5 to + 60)
- 40 to 158 (- 40 to + 70)
9843 (3000)
10 gn
15 gn
2gn
4 gn
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
# 18 to # 14 (1 to 2.5)
# 18 to # 12 (1 to 4)
# 18 to # 12 (1 to 4)
15 (1.7)
# 18 to # 14 (1 to 2.5)
04/01

Related parts for LC1K0910G7