GSC20-24G SL Power ( Ault / Condor ), GSC20-24G Datasheet

no-image

GSC20-24G

Manufacturer Part Number
GSC20-24G
Description
POWER SUPPLY, SWITCHING; 20 W; 90 TO 264 VAC; 24 V; 0.6 A (MAX.); 0.85 A; 0.75%
Manufacturer
SL Power ( Ault / Condor )
Type
Commercialr
Datasheet

Specifications of GSC20-24G

Brand/series
GLC20 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 0.85 A
Power, Output
20 W
Primary Type
AC-DC
Voltage, Input
90 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
18
GSC20 Commercial
20 Watt Single Output Global Performance Switchers
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at minimum 120 Vac, 60 Hz with
full rated output load is 0.6 A.
Hold-up Time
15 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
Normal continuous output power is 20 W, 24 W peak for
60 s maximum duration, 10% duty cycle. Factory set to
begin power limiting at approximately 28 W.
Output Regulation
Regulation from initial setpoint measured by changing
load from 5% load to 50% load or 50% load to full load in
either direction. Initial setpoint tolerance is measured at
50% load. A minimum load of 5% of the output current is
required to maintain proper regulation.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with scope probe directly across output
terminals of the power supply with load terminated with
0.1 uF capacitor.
Transient Response
Main output: 750 µs typical response time for return to
within 0.5% of final value for a 50% load step within the
regulation limits of minimum and maximum load, l/ t
<0.2 A/µs Maximum voltage deviation is 3.5%. Startup/
shutdown overshoot less than 2%.
Overvoltage Protection
Built in with firing point set per ratings table. OVP firing
reduces voltage to less than 50% of nominal voltage in
50 ms.
Turn-on time
Less than 1 second at 115 Vac, 25º C (inversely propor-
tionate to input voltage and thermistor temperature.
FEATURES:
• Industry’s smallest 20 W switcher
• Business-card size (2.0 x 3.5 x 0.71”)
• Approved to UL60950, CSA-C22.2 No. 60950,
• EMI FCC Class B, CISPR22B
• Overvoltage protection standard
Efficiency
70% minimum at full rated load, nominal input voltage.
Efficiency increases as output voltage increases.
Input Protection
Internal ac fuse provided on all units.
Inrush Current
Inrush is limited by internal thermistor. The inrush at 230
Vac, averaged over the first ac half-cycle under cold start
conditions will not exceed 32 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output
power; derate output current and total output power by
2.5% per °C above 50°C. See Environmental Specifica-
tions on next page.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Safety
Condor D.C. Power Supplies, Inc. declares under our sole
responsibility that all GSC models are in conformity with
the applicable requirements of EN60950 following the
provisions of the Low Voltage Directive 73/23/EEC. All
GSC models are approved to UL60950, CSA-C22.2 No.
60950, EN60950, IEC60950 with CB Certificate.
EN60950, IEC60950 with CB Certificate
marked to LVD
EN61000-4-5, 1 kV diff., 2 kV com.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-3, 3 V/meter

Related parts for GSC20-24G

GSC20-24G Summary of contents

Page 1

... GSC20 Commercial 20 Watt Single Output Global Performance Switchers SPECIFICATIONS: Ac Input 90-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at minimum 120 Vac with full rated output load is 0.6 A. Hold-up Time 15 ms minimum from loss of ac input at full load, nominal line (115 Vac). ...

Page 2

... GSC20 Commercial GSC20 MECHANICAL SPECIFICATIONS Watt Single Output Units should be allowed to warm up/operate under non-condensing conditions before application of power Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± duration, ± direction, 3 orthogonal axes, ...