K8AB-PH1 Omron Automation, K8AB-PH1 Datasheet

no-image

K8AB-PH1

Manufacturer Part Number
K8AB-PH1
Description
RELAY; POWER; 3 PHASE; 200 TO 500 VAC
Manufacturer
Omron Automation
Datasheet

Specifications of K8AB-PH1

Lead Free Status / Rohs Status
RoHS Compliant part
Three-phase Phase-sequence Phase-loss
Relay Using Voltage Detection Method
• Prevents reverse motor rotation due to incorrect wiring.
• Distinguishes between positive phases, reversed phases, and
• Voltage detection method enables application for any load
• One SPDT output relay, 6 A at 250 VAC (resistive load).
• Output status can be monitored using LED indicator.
Model Number Structure
■ Model Number Legend
1. Basic Model
2. Functions
3. Rated Input Voltage
Ordering Information
■ List of Models
Note: The power supply is shared with the rated input voltage.
K8AB-@@
Phase-sequence Phase-loss Relay
phase loss when power is turned ON.
current.
Phase-sequence Phase-loss Relay
K8AB-PH
K8AB: Measuring and Monitoring Relays
PH:
1:
1
Refer to Safety Precautions for the K8AB
Series. Refer to page 5 for the Q&A section.
Phase-sequence Phase-loss Relay
200 to 500 VAC
2 3
Phase sequence and phase loss
monitoring
Functions
200 to 500 VAC
Rated input voltage (See note.)
K8AB-PH1
CSM_K8AB-PH_DS_E_1_1
Model
1

Related parts for K8AB-PH1

K8AB-PH1 Summary of contents

Page 1

... Rated Input Voltage 1: 200 to 500 VAC Ordering Information ■ List of Models Phase-sequence Phase-loss Relay Phase sequence and phase loss monitoring Note: The power supply is shared with the rated input voltage. Functions Rated input voltage (See note.) 200 to 500 VAC CSM_K8AB-PH_DS_E_1_1 Model K8AB-PH1 1 ...

Page 2

... Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact Al 1-8RD (for AWG18) manufactured by Phoenix Contact Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact Munsell 5Y8/1 ABS resin (self-extinguishing resin) UL94-V0 Approx. 110 g Mounted to DIN Track or via M4 screws (tightening torque: 1.2 N·m) 22.5 (W) × 90 (H) × 100 (D) mm K8AB-PH 2 ...

Page 3

... Note: 1. Motor load phase loss cannot be detected. To detect motor load phase loss, use the K8AB-PM or K8AB-PA. 2. The K8AB-PH output relay is normally operative and L3 function both as the power supply terminals and as input terminals. If the voltage drops below the minimum input voltage (60%), then the Relay will not operate due to an undervoltage ...

Page 4

... Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. 2. Outputs Terminals 11, 12, and 14 are output terminals for SPDT. Dimensions Phase-sequence, Phase-loss Relays K8AB-PH1 Indicators Item Terminal block Power indicator (See notes 1 and 2.) ...

Page 5

... As the graph shows, voltage is induced at the motor terminals even if there is phase loss for a motor load, so the K8AB-PH1 cannot detect phase loss for motor loads during operation. Use the K8AB-PH1 to detect phase loss at startup. ...

Page 6

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a ...