HC28-2-A+G SL Power ( Ault / Condor ), HC28-2-A+G Datasheet

no-image

HC28-2-A+G

Manufacturer Part Number
HC28-2-A+G
Description
POWER SUPPLY; 28 VDC; 2 A; 47 TO 63 HZ; 0.05; 0.05; 0.01%/ DEGC (MAX.) ROHS COMP
Manufacturer
SL Power ( Ault / Condor )
Type
Commercialr
Datasheet

Specifications of HC28-2-A+G

Brand/series
HC Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
28 VDC @ 2 A
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100, 120, 215, 230, 240 VAC
Voltage, Output
28 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
• World-wide ac input ranges and safety
• Industry standard packages
• Commercial UL/CSA TUV/IEC approved—
• Burn-in with cycling; 3-year warranty
• Capacitors have highest CV & ripple current
• Medical Approved to UL2601-1/60601-1,
• Medical leakage 10 μA
• MTBF 200,000+ hours per MIL-HDBK-217D
• All electrolytic caps rated at 105°C
• Transformer insulation meets Class F (155°C)
• Exceed FCC and CISPR22, Class B conducted
• RoHS Compliant models available (G suffix)
SPECIFICATIONS
Ac Input
100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11%; 47 to 63Hz. Toler-
ance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50
Hz operation.
Dc Output
See voltage rating chart. Adjustment range ±5% minimum except HA series.
Line Regulation
±0.05% for a 10% change.
Load Regulation
± 0.05% for a 50% load change.
Output Ripple
3 mV +0.05% of output voltage, peak to peak maximum. All “3-terminal regu-
lator” outputs: 3 mV +0.2% peak to peak maximum.
Transient Response
<50 microseconds for 50% load change.
Short Circuit Protection
Automatic current limit/foldback.
Overvoltage Protection
Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models use optional over-
voltage protection.
International + Linears
Summary:
All specifications are typical at nominal input, full load at 25
standards
models to UL/CSA 60950; EN/IEC60950-1
ratings
(most units)
emissions
IEC60601-1 and CSA601.1
marked to LVD
D C P o w e r S u p p l i e s
International + Linears
Commercial/Medical
O
C unless otherwise stated
Remote Sensing
Provided on all models; open sense lead protection built-in (except HA & HTAA
series).
Stability
±0.05% for 24 hours after warmup.
Temperature Rating
0 to 50°C full rated, derated linearly to 40% at 70°C.
Temperature Coefficient
±0.01%/°C maximum.
Efficiency
5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.
Logic Inhibit and Current-Share
F & G models.
Medical Stock and Vibration
Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1.
Per Mil-Std-810D, Method 516.3, Procedure III.
Storage
-40 to +85 °C.

Related parts for HC28-2-A+G

HC28-2-A+G Summary of contents

Page 1

International + Linears Summary: • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved— models to UL/CSA 60950; ...

Page 2

... F15-15-A+G * HA24-0.5-A+G HB24-1.2-A+G MB24-1.2-A HC24-2.4-A+G MC24-2.4-A HN24-3.6-A+G HD24-4.8-A+G MD24-4.8-A HE24-7.2-A+G * F24-12-A+G * HA24-0.5-A+ (24 V)G HB28-1-A+G MB28-1-A HC28-2-A+G MC28-2-A HN28-3-A+G HD28-4-A+G MD28-4-A HE28-6-A+G * F24-12-A+* (28 V)G HB48-0.5-A+G HC48-1-A+G HD48-3-A+G ** HE48-4-A+G F48-6-A+G * Notes: 1. All single output models have isolated outputs. 2. Model G5-50-OV-A+ not RoHS compliant ...

Page 3

INTERNATIONAL + LINEAR MECHANICAL SPECIFICATIONS A CASE (WT. 1 LB.) C CASE (WT. 4 LB.) B CASE (WT. 2 LB.) D CASE (WT. 7.5 LB.) ...

Page 4

INTERNATIONAL + LINEAR MECHANICAL SPECIFICATIONS E CASE (WT. 10 LB.) F CASE (WT. F5: 14 LB.; F15, 24: 18 LB.)) G CASE (WT. G5: 19 LB.) N CASE (WT. 7 LB.) L CASE (WT. 1 LB.) DETAIL A-A ...

Related keywords