H7CX-A114-N AC100-240 Omron Automation, H7CX-A114-N AC100-240 Datasheet

no-image

H7CX-A114-N AC100-240

Manufacturer Part Number
H7CX-A114-N AC100-240
Description
Counter; 11 Pin Socket; -10 to 55 degC
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A114-N AC100-240

Brand/series
H7CX
Connection Type
11 Pin Socket
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
Ultra-compact Counter Provides More
Complete Functionality.
Basic Features
Safety and Reliability
Other Features
*1.For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63.7 mm (case dimension).
*2.The H7CX-A11 and H7CX-R11 have only red characters.
*3.The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models).
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner
control panels.
Easier to Read
For better readability, the character height for the present value
display is 12 mm on models with 4 digits, the largest class in the
industry. The wide viewing angle and brightness provide excellent
visibility. The number of display segments has also been increased to
make settings easier to understand, and the present value display
can be switched between red, green, and orange so that output status
can be seen from a distance.
Note: The display color can be switched on all models except for the
The Easiest Operation
Operation is simplified by the
Up/Down Key for each digit
on 4-digit models and Up
Key for each digit on 6-digit
models.
Model with 4 Digits Model with 6 Digits
• Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw
• Better readability with character height of 12 mm on 4-digit models and 10 mm
• The present value display characters can be switched between red, green, and
• New set value limit and counter functions have been added.
• Front Panel can be changed to white or light gray.
• Models with two independent tachometer inputs have been added to the series.
12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC Models with Screw Terminals: 78 mm*
Models with Sockets: 63.7 mm (case dimension)
* Power supply circuit and input circuits are isolated for safety and reliability.
Multifunction Counter/Tachometer
H7CX-@
Terminals).
on 6-digit models.
orange.
New Product
H7CX-A11 and H7CX-R11.
*2
(actual size)
12 mm
*1
(Display example)
-N
New models
(actual size)
10 mm
Model with 4 Digits
Previous
models
models
New
Easy to read from the top, bottom,
and sides!
Previous
models
Model with 6 Digits
*3
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated inside the Counter/
Tachometer. Previous non-isolated counters had wiring restrictions
and could be damaged if wired incorrectly. The H7CX removes these
worries.
Note: Except 12 to 24-VDC models.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Output Counter
The output counter counts the number of times the output turns ON
(alarms can be displayed and the count can be monitored in
increments of 1,000 operations). This counter is useful in managing
the service life of the Counter/Tachometer or the load.
For 1,000 pieces
Setting the upper limit of the set
value enables worry-free operation.
No overflow
Refer to Safety Precautions on page 52.
1

Related parts for H7CX-A114-N AC100-240

H7CX-A114-N AC100-240 Summary of contents

Page 1

... Isolated Power Supply and Input Circuits Power supply circuit and input circuits are isolated inside the Counter/ Tachometer. Previous non-isolated counters had wiring restrictions and could be damaged if wired incorrectly. The H7CX removes these worries. Note: Except 12 to 24-VDC models. Set Value Limit You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes ...

Page 2

... DC 2-wire sensors can be connected for a wide range of input devices. Waterproof, Dust-proof Structure (UL508 Type 4X and IP66) Worry-free application is possible in locations subject to water. Note: When the Y92S-29 Waterproof Packing is used. Model Number Structure Model Configuration H7CX-A-series Multifunction Preset Counter Model Classification Model H7CX-A@-N 1-stage preset Yes counter ...

Page 3

... Twin counter • Tachometer H7CX-R Tachometer • Tachometer Series Note: 1. The functions that are provided depend on the model. Check detailed specifications before ordering. 2. Refer to page page 37 and later for information on H7CX-R Tachometers. 2. External connections Symbol Meaning None Screw terminals 11 11-pin socket 5 ...

Page 4

... Applicable Counters Page 4-digit Counter 12 6-digit Counter Page 12 Page 12 Page 12 Page 12 Connectable Counter/ Tachometers --- Round crimp terminals cannot be used on Finger-safe Sockets. H7CX-@11@-N Use forked crimp terminals. A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Page 13 Remarks Page 13 ...

Page 5

... No-voltage input/voltage input (switchable) External power supply 12 VDC ( 10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for Correct Use on page page 53 for details. • Contact output 250 VAC/30 VDC, resistive load (cos =1), Minimum applied load VDC (failure level: P, reference value) Control output • ...

Page 6

... VAC, 50/60 Hz for 1 min between power supply and input circuit for all models Dielectric strength except H7CX-@D@ (1,000 VAC for 24 VAC/ VDC) 1,000 VAC (for H7CX-@SD@), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-@SD@) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts 3 ...

Page 7

... Holds the measurement value and outputs. (The reset 2 input can be used when the input mode Inputs Reset/reset 1 is 2-input independent measurement.) • The reset indicator is lit when the value is being held. Outputs OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached. Reset operation 0 H7CX-A@-N 7 ...

Page 8

... OUT2 ( ) ( ) Terminals 1 and 6 are connected internally. Transistor Output • The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN Output PNP Output Load Load + Power for load 8 H7CX-AD-N/-A4D-N ...

Page 9

... Input circuits control circuit Key switch circuit Note: All models except for H7CX-@D-N have basic insulation. Input Connections The inputs of the H7CX-@-N are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or Sensor sensor ...

Page 10

... Set Value 1, 2 Stage Indicator 7. Present Value (Main Display) (Character height (6-digit: 10 mm), red*) * Characters on models with screw terminals (H7CX-A11@) can be switched between red, green, and orange. 8. Set value (Sub-display) (Character height: 6 mm, green) 9 ...

Page 11

... H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N (Flush Mounting Models) H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N (Flush Mounting/Surface Mounting Models) Dimensions with Flush Mounting Adapter H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) ...

Page 12

... If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Flush Mounting Adapter Y92F-30 Y92F-45 ...

Page 13

... RESISTIVE 7.8 5 4.5 Dimensions 27 dia. 25.6 45 4.5 6.2 16.3 Dimensions 47.7 47 16.5 24.6 27.6 H7CX-A@-N Terminal arrangement Mounting hole and internal connections dimensions Two 4.5-dia. holes 0.2 Note: The Socket can 9 3 also be mounted DIN track. (Top View) Terminal arrangement and internal connections ...

Page 14

... H7CX-A@-N Optional Products for Track Mounting Mounting Track PFP-100N PFP-50N Mounting Track PFP-100N2 End Plate PFP-M Spacer PFP-S Note: Order Spacers in increments of 10 1,000 (500)* * The values shown in parentheses 4 1,000 10 6.2 1 pan head 1 screw 50 35.5 35.3 1.8 11.5 10 1.3 M4 spring washer 4 ...

Page 15

... Use the following settings. Setting for Tachometer Operation Refer to page page 27 the time of delivery, the H7CX is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage preset counter configuration.) Refer to page page 35 for information on switching models. I/O Functions for Counter Operation Step1 Set the basic parameters ...

Page 16

... Note: Displayed for terminal-block models (except H7CX-A11@) only. will not be displayed. *3 When Using Dual Counter Operation • Set the dual count calculating mode using the UD Keys. *4 add ...

Page 17

... Output 2 (OUT2) ON count alarm set value Output 1 (OUT1) ON count monitor value Output 2 (OUT2) ON count monitor value H7CX-A@-N Counter kp-7 (KP-7) 0 9999 (0 1000 times) (9999 1000 times) Note: The monitor value is only displayed. It cannot be set. 0 9999 (0 1000 times) (9999 1000 times) ...

Page 18

... The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 9. Display Color (colr) (Displayed for terminal block models (except H7CX-A11@) only.) Set the color used for the present value. Output OFF* red Red (fixed) ...

Page 19

... Output Allocation (otst) When using an H7CX-AU@-N model as a 2-stage counter, the output can be flexibly allocated to either stage The transistor output can be allocated to SV1 and the contact output to SV2 or vice verse the following tables. ...

Page 20

... H7CX-A@-N Counter Operation in Run Mode I/O Functions for Counter Operation • Set values for each digit as required using the U 1-stage Preset Counter Present value Set value 2-stage Preset Counter with Absolute Value Setting Present value Set value 1 Present value Set value 2 • ...

Page 21

... If they are less, a count error of 1 may occur. Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz The meaning of the H and L symbols in the tables is explained 2 below. 1 Symbol Input method H L H7CX-A@-N Counter DOWN (Decrement) Mode A A Prohibit ...

Page 22

... H7CX-A@-N Counter Input/Output Mode Settings I/O Functions for Counter Operation If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for output 2 will be performed. When using a 2-stage model as a 1-stage preset counter, total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously ...

Page 23

... A 0 OUT1 OUT2 Note: 1. The full scale (FS) for H7CX 4-digit models is 9999. 2. When the present value reaches 999999, it returns Counting cannot be performed during reset/reset 1 input reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF there is power failure while output is ON, output will turn ON again when the power supply has recovered. ...

Page 24

... H7CX-A@-N Counter Reset/ reset 1 999999 Set value 2 Set value 1 0 K-2 99999 OUT1 OUT2 Reset/ reset 1 999999 Set value 2 Set value 99999 OUT1 OUT2 Output mode setting Reset/ reset 1 999999 Set value 2 Set value 99999 OUT1 OUT2 Reset/ reset 1 999999 Set value 2 ...

Page 25

... Total count value 0 Note: The full scale (FS) for H7CX 4-digit models is 9999. Batch Counter Operation The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed. Reset 1 Reset 2 (batch counter reset) ...

Page 26

... H7CX-A@-N Counter Twin Counter Operation Two independent counters are built in. Counter input Reset input Counter 1 display Counter 1 present value Present value display and setting Reset Key Only counters appearing on the display will be reset. Note: 1. Only 2-stage models 2. Increment mode only for counters 1 and 2. ...

Page 27

... Setting Procedure Guide Tachometer Operation Step1 The H7CX is factory-set to the 2-stage counter configuration (1-stage counter configuration for H7CX-AU@-N models). Enter configuration selection mode using the following chart and set the tachometer mode. Note: can be performed first, followed by Step2 Configuration Power ON selection mode ...

Page 28

... H7CX-A@-N Tachometer Step3 Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel. Change to Function Setting Mode. Power min. Function Run mode setting mode * min the mode is switched to the function setting mode during operation, operation will continue. ...

Page 29

... KP-2) ( KP-3) ( KP-4) ( KP-5) ( KP-6) (Pulse width measurement) *2 Set each digit using the individual U Keys cont (Cont (10 ms min.)) H7CX-A@-N Tachometer o-r g-o o-g kp-7 ( KP-7) Output 1 (OUT1 9999 count alarm (0 1000 times) (9999 1000 times) set value ...

Page 30

... It can also be used to stop measurements and disable outputs until the rotating body reaches the normal rate of rotation, after the power supply to the H7CX and rotating body are turned ON at the same time. Prescale value ( ) 1/N ...

Page 31

... OFF. Output Allocation (otst) Measured value is displayed in red when When using an H7CX-AU@-N model as 2-stage counter, each output both control outputs 1 can be flexibly allocated to either stage and 2 are OFF. The transistor output can be allocated to SV1 and the contact output to SV2 or vice verse the following tables ...

Page 32

... H7CX-A@-N Tachometer ON Count Alarm Set Values for Outputs 1 and 2 (OUT1 and OUT2) (on1a and on2a) Set the ON count alarm values for the outputs 1 and 2. The limit can be set to between 0 1000 (0 times) and 9999 (9,999,000 times). Only the underlined values are set. The alarm will be disabled set ...

Page 33

... Displayed for the 2-input input mode. Peak hold value 1 Bottom hold value 1 Peak hold value 2 Bottom hold value 2 H7CX-A@-N Tachometer • Peak/bottom hold value The peak (maximum) and bottom (minimum) values are displayed after counting starts. • Peak/bottom hold value 2 Peaks (maximums) 1 and 2 and bottoms (minimums) 1 and 2 are displayed after counting starts ...

Page 34

... H7CX-A@-N Output Mode Setting and Operation Tachometer Operation Input mode Output mode setting setting Comparison value 2 Measurement value Upper and Comparison value 1 lower limit (HI-LO) Comparison value 2 Measurement value Comparison value 1 Area (AREA) 1 input Error Absolute ratio Error ratio Comparison value 2 ...

Page 35

... Select which H7CX configuration is used (i.e., preset counter, total and preset counter, batch counter, dual counter, twin counter, or tachometer) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the display on the front of the H7CX. ...

Page 36

... H7CX-A@-N Key Protect Level It is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7) when the key-protect switch is set to ON. The key protect level is set in the function setting mode. The key protect indicator is lit when the key-protect switch is ON. ...

Page 37

... Case color Black (N1.5) *1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for CC power. *2. The display is lit only when the power is ON. Nothing is displayed when power is OFF. 48) for the H7CX Tachometer H7CX-R11@-N AMD-compatible mode (continuous ...

Page 38

... Immunity RF-interference: EMC Immunity Conducted Disturbance: Immunity Burst: Immunity Surge: Immunity Voltage Dip/Interruption: * The following safety standards apply to the H7CX-R11@. cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. I/O Functions Count, count 1, Reads counting signals. ...

Page 39

... VDC ( ) External power supply ( ) ( ) Transistor Output • The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN Output PNP Output Load Load + Power for load Power for load • ...

Page 40

... H7CX-R@-N Input Connections The inputs of the H7CX-R are no-voltage (short-circuit or open) inputs or voltage inputs. They are set for use as voltage inputs at the time of delivery. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or sensor H7CX-R11 H7CX-R11@ 3 --- 6 H7CX-R11W@ H7CX-R11W@ Note: Operates when the transistor turns ON. ...

Page 41

... P2CF-11(-E) (order separately) Front Connecting Socket * These dimensions vary with the kind of DIN track (reference value). 100.9 103.2* H7CX-R@-N Operation Keys 7. Mode Key (Used to switch mode and setting items.) 8. Hold Key (Used to sustain the measurement value and output Keys ...

Page 42

... If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54 against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Hard Cover Y92A-48 Connection Sockets Refer to Connection Sockets on page page 13 for details ...

Page 43

... Output mode Refer to the table on the right. Refer to the table on the right. 4 Output mode Note: The characters displayed in reverse video are the default settings. *3. For the H7CX-R11W@, the counting speed will be 5 kHz even if 10 kHz is selected. ON OFF (Factory setting) ON Pin 1 ...

Page 44

... H7CX-R@-N Step2 Change to Function Setting Mode. Power min. Run mode 3 s min. Decimal point position (DP) Prescale value (PSCL) Averaging method (AUGT) Auto-zero time (AUTO0) Startup time (STMR) Peak/bottom hold enabled (DHLD) Output hysteresis (HYS) Output OFF delay (OFFD) Set value upper limit ...

Page 45

... Upper and lower limit (HI-LO), area (AREA), upper limit (HI), and lower limit (LO) can be set. For the H7CX-RW@, the upper limit (HI- HI) and lower limit (LO-LO) can be set. (For details on the operation of the output modes, refer to Output Mode Settings on page page 49.) ...

Page 46

... It can also be used to stop measurement and disable output until the rotating body reaches the normal rate of rotation, after the power supply to the H7CX and rotating body are turned ON at the same time. Display Startup time Comparison value ...

Page 47

... Bottom hold value 1 Note: The held values will be initialized when the Peak hold value 2 Bottom hold value 2 H7CX-R@-N • Measurement Value Displays the currently measured value. • Comparison Value, Comparison Value 1, and Comparison Value 2 Set the comparison value, comparison value 1, and comparison value 2 ...

Page 48

... H7CX-R@-N Key Protect Level When the key-protect switch is set to ON possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7). The key protect level is set in the function setting mode. The key protect indicator is lit when the key-protect switch is ON ...

Page 49

... Output Mode Settings Models Other Than H7CX-R11W@ in Tachometer Mode Output mode Operation setting Comparison value 2 (Upper-limit) Measurement value Upper and Comparison value 1 (Lower-limit) lower limit OUT ON condition: Measurement value Comparison value 1 or Measurement value Comparison value 2 Note: When comparison value 1 Comparison value 2, the output isalways ON regardless of the comparison value ...

Page 50

... Comparison value (lower limit) * The H7CX-R11W@-N does not have a hold input. Operation in DIP Switch Monitor Mode The H7CX-R is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. Power ON ...

Page 51

... Precautions on Replacing the AMD-S The H7CX-R11-N is the recommended model for replacing the AMD-S-series Motion Detector. Refer to the following precautions before replacing the AMD-S. Terminal Arrangement and Wiring Connections AMD-S • Connection Sockets: 8PFA Black (white) Sensor Brown (red) Blue (black 8PFA ...

Page 52

... ON if the set value is equal to the present value. • When changing the comparison value during operation, because the H7CX uses a constant read-in system, the output status will change if the comparison value is changed to a value on the other side of the present value. ...

Page 53

... Precautions for Correct Use • H7CX models with 24-VDC power supply use a transformer-free power supply method in which the power supply terminals are not isolated from the signal input terminals non- isolating DC power supply is used, unwanted current paths may occasionally burn or destroy internal components depending on the wiring. Always check the wiring sufficiently before use. • ...