G2R-2SND-DC12(S) Omron Automation, G2R-2SND-DC12(S) Datasheet - Page 10

no-image

G2R-2SND-DC12(S)

Manufacturer Part Number
G2R-2SND-DC12(S)
Description
RELAY; GENERAL PURPOSE; DPDT; PLUG-IN; LED INDICATOR/DIODE; 12VDC
Manufacturer
Omron Automation
Datasheet

Specifications of G2R-2SND-DC12(S)

Lead Free Status / Rohs Status
RoHS Compliant part
Mounting Tracks
End Plate
Precautions
PFP-100N, PFP-50N
PFP-M
• Do not use the test button for any purpose other than testing. Be
• Check that the test button is released before turning ON relay cir-
• If the test button is pulled out too forcefully, it may bypass the mo-
• Use an insulated tool when you operate the test button.
4.5
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
cuits.
mentary testing position and go straight into the locked position.
It is recommended to use a panel 1.6 to 2.0 mm thick.
15 25
10
25
1,000 (500)
50
11.5
25
Cation
10
10
25
M4 x 8 pan
head screw
7.3±0.15
15 (5)
35±0.3
10
6.2
1.3
4.8
1
1.8
27±0.15
1
35.5 35.3
1.8
PFP-100N2
4.5
Spacer
Precautions for P2RF-@-S Connection
PFP-S
• Do not move the screwdriver up, down, or from side to side while it
• Do not insert the screwdriver at an angle. Doing so may break the
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
side of the socket and result in a short-circuit.
15 25
10
25
1,000
25
10
25 15
5
44.3
35±0.3 27
12
16.5
16
G2R-@-S
1
24
34.8
16
29.2
1.5
10

Related parts for G2R-2SND-DC12(S)