G2R-2SND-DC12(S) Omron Automation, G2R-2SND-DC12(S) Datasheet - Page 3

no-image

G2R-2SND-DC12(S)

Manufacturer Part Number
G2R-2SND-DC12(S)
Description
RELAY; GENERAL PURPOSE; DPDT; PLUG-IN; LED INDICATOR/DIODE; 12VDC
Manufacturer
Omron Automation
Datasheet

Specifications of G2R-2SND-DC12(S)

Lead Free Status / Rohs Status
RoHS Compliant part
Contact Ratings
Note: P level: λ
Characteristics
Note: Values in the above table are the initial values.
Approved Standards
UL 508 (File No. E41643)
CSA 22.2 No.0, No.14
(File No. LR31928)
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Contact resistance
Operate (set) time
Release (reset) time
Max. operating
frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1-S SPDT
G2R-2-S DPDT
G2R-1-S SPDT
G2R-2-S DPDT
Model
Model
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
Item
Contact
Contact
form
form
60
= 0.1 x 10
5 to 110 VDC
5 to 240 VAC
5 to 110 VDC
5 to 240 VAC
Coil ratings
Coil ratings
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Mechanical:
Electrical:
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating:
Operating:
Approx. 21 g
-6
/operation
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
1 pole
Resistive load
(cosφ = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
440 VAC, 125 VDC
10 A
2,500 VA,
300 W
100 mA at 5 VDC
Contact ratings
Contact ratings
18,000 operations/hr
1,800 operations/hr (under rated load)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
200 m/s
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
–40°C to 70°C (with no icing or condensation)
5% to 85%
1 pole
2
when energized; 100 m/s
2
6 x 10
6 x 10
6 x 10
6 x 10
ations
ations
Oper-
Oper-
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
3
3
3
3
IEC/VDE (EN61810)
LR
1 pole
2 poles
1 pole
2 poles
2
Contact
Number
of poles
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
when not energized
form
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 to 110 VDC
5 to 240 VDC
5 to 110 VDC
5 to 240 VDC
Coil ratings
Coil ratings
2 poles
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
10 mA at 5 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
2 poles
Contact ratings
Contact ratings
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
G2R-@-S
100 x 10
100 x 10
Operations
100 x 10
100 x 10
Operations
3
3
3
3
3