SLU100ASA ATC Diversified Electronics, SLU100ASA Datasheet

no-image

SLU100ASA

Manufacturer Part Number
SLU100ASA
Description
Monitor, Phase; 10 A; 550 VAC; 8; 0 to degC; cULus Listed, CE Marked
Manufacturer
ATC Diversified Electronics
Datasheet

Specifications of SLU100ASA

Temperature, Operating
0 to +55 °C
Phase Unbalance
2% to 10%, Adjustable
Fault Delay
0.1 to 25 Sec, Adjustable
Restart
0.5 to 300 Sec, Adjustable (Auto Restart)
Relay Rating
10 A @ 240 VAC
208
SLU-100-ASA
\\\
\\\
\\\
MODEL NUMBER
SLU-100-ASA
SLU-100-ASD
SLU-100 Series
ORDERING INFORMATION
TOP LABELS
DIMENSIONS
DIN Rail
SLU-100-ASD
Universal Phase Monitor
Din Rail Mount Universal Phase Monitor
(INCHES)
DESCRIPTION
Plug-In
DIN Rail
Diversified Electronics
Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection
port for application assistance.
against premature equipment failure caused by voltage faults on 3-Phase
systems (Wye or Delta). The SLU Series multi-mode phase monitoring
NOTE: Not recommended for generator or variable frequency drive applications. Call technical sup-
relay, was designed for the convenience of electrician's, maintenance
managers and engineers. A single SLU Phase Monitoring Relay can be eas-
connections to neutral are NOT required.
ily adjusted for the voltage, imbalance percentage and time delay require-
Both Delta and Wye systems may be monitored. In Wye systems,
ments to protect against unbalanced voltages or single phasing regardless
of any regenerative voltages.
\\\
AUTO
RANGING
SCALES
VOLTAGE
BAND
MAXIMUM
VOLTAGE
PHASE
SEQUENCE
POWER
REQUIRED
PHASE
UNBALANCE
PHASE SHIFT 13° Drop-out, 12° Pick-up (Ø-Loss)
FREQUENCY
SHIFT
RESET
RELAY
OUTPUT
INDICATORS
RESPONSE
TIMES
TEMPERATURE
RATINGS
REPEAT
ACCURACY
TERMINALS
(DIN)
ENCLOSURE
WEIGHT
SPECIFICATIONS
550 VAC (Line-to-Line)
ABC (Will Not Operate On CBA Sequence)
90VA Max.
2% to 10%, Adjustable Drop-out
50/60 Hz
Automatic or Manual Mode
SPDT, 10A @ 240VAC
Resistive, 1/2 HP @240VAC
1% @ Fixed Condition
Slotted Screw Terminal Clamps, 12AWG Max.
0.35 to 0.5 lbs.
atcdiversified.com
(Green LED)
Severe Fault
Fault Delay
Frequency
(Red LED)
Power Up
Hysteresis
Drop-out
Drop-out
Style “A”
Operate
Storage
Pick-up
Pick up
Normal
Restart
60Hz
50Hz
Fault
DIN
Nominal Line-to-
10% of Setting
±10% of Range Setting
(Under/Over)
±7% of Range Setting
(Under/Over)
± 4%
± 3%
2.5 S Minimum
0.1 to 25 S, Adjustable
100mS (Phase-Loss, Unbalance
or Phase Reversal)
0.5 to 300 S, Adjustable
(Auto Reset)
32° to 131°F (0° to +55°C)
-49° to 185°F (-45° to +85°C)
LEXAN
35mm DIN Rail, 14 Term
Polycarbonate Housing
380, 415, 440,
208, 220, 240
208, 220, 240
346, 380, 415
Line Voltages
Restart Delay
Fault Delay
460, 480
Flashing
Active
Active
®
Dust Cover
800.727.5646
De-energized
Continuous
Adjustable
Energized
200-250
360-500
200-250
330-430
Range
Relay
Relay

Related parts for SLU100ASA

Related keywords