SUA2200RMXL3U American Power Conversion (APC), SUA2200RMXL3U Datasheet

no-image

SUA2200RMXL3U

Manufacturer Part Number
SUA2200RMXL3U
Description
Smart UPS XL, 2200VA/1850W, Input 120V/Output 120V, Extended Run Time, 3U High
Manufacturer
American Power Conversion (APC)
Type
Networkr
Datasheet

Specifications of SUA2200RMXL3U

Capacity
1850 VA
Color
Black
Communication
DB9, RS232, SmartSlot, USB
Dimensions
133mmH×483mmW×660mmD
Input Type
NEMA 5-20P
Length, Cord
2.44 m
Mounting Type
Rack/Tower
Output Type
(9) NEMA 5-15R, (2) NEMA 5-20R
Power, Rating
1850 W
Time, Backup
8.2 min.
Voltage, Output
120 V
Voltage, Supply
1850/1850 W/VA
Weight
59.55 kg
Smart-UPS XL
APC Smart-UPS XL 2200VA RM 3U 120V
APC Smart-UPS XL, 1850 Watts / 1850
VA,Input 120V / Output 120V, Interface Port
DB-9 RS-232, USB, SmartSlot, Extended
runtime model, Rack Height 3 U
Includes: CD with software, Rack Mounting
support rails, Smart UPS signalling RS-232
cable, USB cable, User Manual
Standard Lead Time: Usually in Stock

Related parts for SUA2200RMXL3U

SUA2200RMXL3U Summary of contents

Page 1

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V APC Smart-UPS XL, 1850 Watts / 1850 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB, SmartSlot, Extended runtime model, Rack Height 3 U Includes: CD with software, Rack Mounting ...

Page 2

... SUA2200RMXL3U Features Replace Battery LED An external Replace Battery LED informs the end-user that the battery needs to be replaced. Pure sinewave battery Prevents interruptions, lost pre-sets, missed DVR recordings, lost multimedia backup server data and premature projector bulb wear and tear when the power goes out ...

Page 3

Disconnected battery Warns when a battery is not available to provide backup power. notification Serial Connectivity Provides management of the UPS via a serial port. InfraStruXure Enables centralized management via the APC InfraStruXure® Manager. Manager Compatible Serviceability User-replaceable Increases availability ...

Page 4

Output Output Power Capacity Max Configurable Power Nominal Output Voltage Output Voltage Distortion Output Frequency (sync to mains for 50 Hz nominal, for 60 Hz nominal Crest Factor Waveform Type Output Connections Input ...

Page 5

Runtime Chart Extended Run Options Energy Use/Efficiency Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with Communications & Management Interface Port(s) Available SmartSlot™ Interface Quantity Control panel Audible Alarm Emergency Power ...

Page 6

Rack Height Net Weight Shipping Weight Shipping Height Shipping Width Shipping Depth Color Units per Pallet Environmental Operating Environment Operating Relative Humidity Operating Elevation Storage Temperature Storage Relative Humidity Storage Elevation Audible noise at 1 meter from surface of unit ...