VQ1301N-51 SMC Corporation, VQ1301N-51 Datasheet

no-image

VQ1301N-51

Manufacturer Part Number
VQ1301N-51
Description
SOLENOID VALVE, BASE MT, 5 PORT, PLUG-IN TYPE, 24VDC, 3 POSITION CLOSED CENTER
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1301N-51

Brand/series
VQ Series
Configuration
3-Position Closed Center
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 3 Position Closed Center Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
Series
5 Port Solenoid Valve
Metal Seal / Rubber Seal
Power saving
Power saving
Standard:
Standard:
High-pressure (1 MPa, Metal seal):
High-pressure (1 MPa, Metal seal):
(Reduced by
(Reduced by
VQ1000/2000
60
60
%
%
0.4
0.4
compared to existing model)
compared to existing model)
compared to existing model)
W
W
0.95
0.95
W
W
CAT.ES11-100A
compliant
RoHS
[Option]

Related parts for VQ1301N-51

VQ1301N-51 Summary of contents

Page 1

Port Solenoid Valve Metal Seal / Rubber Seal Power saving Power saving 0.4 0.4 Standard: Standard (Reduced by (Reduced by compared to existing model) compared to existing model) compared to existing model) High-pressure (1 MPa, ...

Page 2

Port Solenoid Valve Series Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one side permits mounting in three directions. The non-bias, one-clamp structure permits easy valve replacement. Built-in ...

Page 3

A variety of common wiring methods are standardized. F kit (D-sub connector) Number of pins: 15/25 Top entry Side entry kit kit G T (Flat ribbon (Terminal block cable with box) terminal block) Number of pins: 20 Dual 3-port valves, ...

Page 4

VQ /Base Mounted: Variations Series D-sub connector F Conforming to with MIL D-sub connector kit Flat ribbon cable (26/20/16/10 pins) P Conforming to MIL flat kit ribbon cable connector Flat ribbon cable (20 pins) J Conforming to MIL flat ribbon ...

Page 5

Gateway-type serial transmission system Serial unit: EX510 IP20 enclosure compliant Integrated-type serial transmission S system (for Output) kit Serial unit: EX120/123/124 Dust-protected (-XP) Integrated-type serial transmission system (for I/O) Serial unit: EX240 Circular connector M IP65 kit (Dust-tight, Water-jet-proof) Manifold ...

Page 6

Cylinder Speed Chart Series CJ2 Average Pressure 0.5 MPa Series speed Load factor 50% (mm/s) Stroke 60 mm ø6 800 700 600 VQ1101 500 400 Port size: 300 ø6 one-touch fitting 200 100 0 800 700 600 VQ2101 500 400 ...

Page 7

Features Variations Cylinder Speed Chart VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications VQ1000/2000 F kit (D-sub connector) VQ1000/2000 P kit (Flat ribbon cable) VQ1000/2000 J kit ...

Page 8

... Note 3) Inch-size one-touch fittings are also available. Refer to page 57 for details. Note 4) M5 fittings for M5 thread are attached without being incorporated. Simple specials are available with SMC Simple Specials System. Refer to Best Pneumatics No. q for details on applicable models. Kit type/Electrical entry/Cable length F ...

Page 9

How to Order Valves Series 1 VQ1000 Type of actuation 2-position single Seal 2-position double Symbol Specifications 2 2-position double Nil Standard High-speed B response type 3-position closed center High-pressure type K ...

Page 10

VQ1000 Series VQ1000: Manifold Options Blanking plate assembly Individual SUP spacer VVQ1000-10A-1 VVQ1000-P-1- EXH block base assembly Blanking plate with connector VVQ1000-19A- VVQ1000-1C„-„ Connector assembly Blanking plug Port plug KQ2P-„ VVQ0000-58A Direct EXH outlet with Dual flow fitting assembly built-in ...

Page 11

10 ...

Page 12

... Note 3) Inch-size one-touch fittings are also available. Refer to page 57 for details. Simple specials are available with SMC Simple Specials System. Refer to Best Pneumatics No. q for details on applicable models. Kit type/Electrical entry/Cable length F P ...

Page 13

How to Order Valves Series 2 VQ2000 Seal 0 Metal seal 1 Rubber seal Type of actuation 2-position single 4-position dual 3-port valve ( Note N.C. 4-position dual 3-port valve ...

Page 14

VQ2000 Series VQ2000: Manifold Options Blanking plate assembly Individual SUP spacer VVQ2000-10A-1 VVQ2000-P-1- EXH block plate SUP stop valve spacer VVQ2000-19A VVQ2000-24A-1 Blanking plug Port plug KQ2P-„ VVQ1000-58A Silencer (For EXH port) Elbow fitting assembly AN200-KM10 VVQ2000-F-L„ Double check block ...

Page 15

14 ...

Page 16

Plug-in Unit Base Mounted Series Model Type of Series Model actuation Metal seal VQ1100 Single Rubber seal VQ1101 Metal seal VQ1200 Double Rubber seal VQ1201 Metal seal VQ1300 Closed center Rubber seal VQ1301 VQ1000 Metal seal VQ1400 Exhaust center Rubber ...

Page 17

JIS symbol 2-position single 2-position double 2-position double 3-position closed center 3-position exhaust center 3-position pressure center Note) 4-position dual 3-port valve ( N.C. N.C. Note) 4-position dual 3-port valve ( ...

Page 18

VQ1000/2000 F Series Kit (D-sub connector) b D-sub connector reduces installation labor for electrical con- nections. b Using the D-sub connector (25P), (15P as semi-standard) con- forming to MIL standard permits the use of connectors put on the market and ...

Page 19

VV5Q11 VV5Q21 The total number of stations is tabulated starting from station one on the D-side. How to Order Valves Series 1 VQ1000 Function 2 VQ2000 Symbol Specifications Type of actuation Nil Standard 1 2-position ...

Page 20

VQ1000/2000 F Series kit (D-sub connector) VV5Q11 Applicable connector: D-sub connector (25P) (Complies with MIL-C-24308) 63.5 <67.5> (12 Dimensions 65.5 76 86.5 97 107.5 118 L2 83.5 94 ...

Page 21

VV5Q21 Applicable connector: D-sub connector (25P) (Complies with MIL-C-24308) 73.5 <77.5> (12 39.5 Dimensions 101 117 133 149 165 L2 105 121 137 153 169 185 (L3) 137.5 ...

Page 22

VQ1000/2000 P Series kit (Flat ribbon cable) b MIL flat ribbon cable connector reduces installation labor for electrical connection. b Using the connector for flat ribbon cable (26P) conforming to MIL standard permits the use of connectors put on the ...

Page 23

Electrical Wiring Specifications Flat ribbon cable connector Terminal no. SOL.A 1 Station 1 SOL.B 2 SOL.A 3 Station 2 SOL.B 4 SOL.A 5 Station 3 SOL.B 6 SOL.A 7 Station 4 SOL.B 8 SOL.A 9 Station 5 SOL.B 10 ...

Page 24

VQ1000/2000 P Series kit (Flat ribbon cable) VV5Q11 Applicable connector: Flat ribbon cable connector (26P) (Complies with MIL-C-83503) 63.5 <67.5> (12 61.5 Dimensions 65.5 76 86.5 97 107.5 ...

Page 25

VV5Q21 Applicable connector: Flat ribbon cable connector (26P) (Complies with MIL-C-83503) 73.5 <77.5> (12 73.5 Flat ribbon cable connector assembly (26P) AXT100-FC26-1: 1.5 m AXT100-FC26- AXT100-FC26- Dimensions ...

Page 26

VQ1000/2000 J Series kit (Flat ribbon cable) b MIL flat ribbon cable connector reduces installation labor for electrical connection. b Using the connector for flat ribbon cable connectors (20P) con- forming to MIL standard permits the use of connector put ...

Page 27

Electrical Wiring Specifications Terminal no. Flat ribbon cable connector SOL.A Station 1 SOL.B SOL Station 2 SOL SOL.A Station SOL.B Triangle 12 11 SOL.A mark Station indicator ...

Page 28

VQ1000/2000 J Series kit (Flat ribbon cable) VV5Q11 Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 63.5 (12 61.5 Dimensions 65 78.5 89 99.5 ...

Page 29

VV5Q21 Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 73.5 (12 73.5 Dimensions 101 117 133 L2 100 116 132 148 (L3) 125 150 162.5 175 (L4) ...

Page 30

VQ1000/2000 G Series kit (Flat ribbon cable with terminal block) b Terminal block for power supply equipped with a 20 pins flat ribbon cable connection for rationalized connection of valves. b Solenoid valves and power supply can be connected by ...

Page 31

Connector Assembly Electric circuit diagram (Below wiring is the case of all double solenoid connections.) Flat ribbon cable connector Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 Connector terminal no. Station 8 Triangle ...

Page 32

VQ1000/2000 G Series kit (Flat ribbon cable with terminal block) VV5Q11 Indicator light Power supply terminal block (Terminal screw M3) 63.5 (12) 13 43.8 63.4 Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) DIN rail clamp screw Dimensions ...

Page 33

VV5Q21 Power supply terminal block (Terminal screw M3) Indicator light 73.5 (12 73.5 Flat ribbon cable connector assembly (20P) AXT100-FC20-1: 1.5 m AXT100-FC20- AXT100-FC20- Dimensions 101 ...

Page 34

VQ1000/2000 T Series kit (Terminal block box) IP65 compliant b This kit has a small terminal block inside a junction box. The electrical entry port {VQ1000: G 1/2, VQ2000: G 3/4} permits connection of conduit fittings. b Maximum stations: 24 ...

Page 35

Terminal Block Wiring (VQ2000) Open the terminal block cover to connect the wires to the terminal block. Step 1. Removing the terminal block cover Loosen mounting screws (4 pcs.) on the terminal block cover and remove the cover. Step ...

Page 36

VQ1000/2000 T Series kit (Terminal block box) VV5Q11 Top entry port Not machined 63.5 <67.5> (12 Dimensions 66.5 77 87.5 98 108.5 119 L2 126 136.5 147 157.5 ...

Page 37

VV5Q21 (12 (L4) (L3 0 0.5 100.5 Dust-tight, Water-jet-proof Dimensions 150.5 166.5 182.5 198.5 214.5 L2 163 179 195 211 227 (L3) 187.5 200 225 237.5 ...

Page 38

VQ1000/2000 L Series kit (Lead wire) IP65 compliant b Direct electrical entry. Models with one or more stations are available. b (SUP) and (EXH) ports are provided on one side for fur- ther space savings. b Maximum stations are 8. ...

Page 39

VV5Q21 Dust-tight, Water-jet-proof How to Order Valves Series 1 VQ1000 Seal 2 VQ2000 0 Metal seal 1 Rubber seal Type of actuation 1 2-position single 2 2-position double 3 3-position closed center 4 3-position exhaust ...

Page 40

VQ1000/2000 L Series kit (Lead wire) VV5Q11 63.5 <67.5> (12) 13 61.5 39 < >: AC The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). (L4) (L3) 28 Indicator light 1.5 Number ...

Page 41

VV5Q21 73.5 <77.5> (12) 13 Dust-tight, Water-jet-proof C10 [1(P) SUP port] C10: ø10 one-touch fitting Base Mounted Plug-in Unit < >: AC The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket). (L4) (L3) L2 Lead wire ...

Page 42

... Note 2) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct mounting), enter “MM” and give instructions in the manifold specification sheet. Refer to Best Pneumatics No. q for details on EX510 gateway- type serial transmission system. 41 ...

Page 43

Base Mounted Plug-in Manifold How to Order Valves Series 1 VQ1000 2 VQ2000 Type of actuation 2-position single 1 2-position double 2 2-position double 3-position closed center 3 3-position exhaust center 4 3-position pressure center ...

Page 44

VQ1000/2000 S Series kit (Serial transmission) Base mounted plug-in manifold: For EX510 Gateway-type serial transmission system VV5Q11 Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 63.5 (12 61.5 Dimensions ...

Page 45

Base Mounted VV5Q21 Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 73.5 (12 Dimensions 101 117 L2 117 133 149 165 L3 137.5 162.5 175 187.5 ...

Page 46

... Dust-protected: Standard: OMRON Corp.: CompoBus outputs) Dust-protected: Standard: V CC-LINK Dust-protected: Refer to Best Pneumatics No. q for details on the EX120/123/124 integrated-type (Output) serial transmission system. 45 Manifold Specifications Series VQ1000 VQ2000 Dust-protected (-XP) Suffix “-XP” to the end of the part number for the dust-protected SI units ...

Page 47

VV5Q11 VV5Q21 How to Order Valves Series 1 VQ1000 2 VQ2000 Type of actuation 1 2-position single 2 2-position double 3 3-position closed center 4 3-position exhaust center 5 3-position pressure center A 4-position dual ...

Page 48

VQ1000/2000 S Series kit (Serial transmission): For EX120 Integrated-type (Output) serial transmission system VV5Q11 63.5 (12) 13 61.5 With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26. 10.5n + 56.3 + ...

Page 49

VV5Q21 16n + 108 L1 34.5 1 Drawing shows a SC case. Dust-protected SI unit 73.5 (12) 13 Dimensions 101 ...

Page 50

... Note 5) Inch-size one-touch fittings are available. Refer to “Semi-standard” on page 57 for details. Refer to Best Pneumatics No. q for details on the EX240 integrated-type (Output) serial transmission system. How to Order Manifold ...

Page 51

VV5Q21 (Serial transmission kit: EX240) 14.6 8.1 If the input block is attached, it comes with a bracket Dimensions 68.5 84.5 100.5 116.5 132.5 148.5 L2 218 234 250 266 282 ...

Page 52

VQ2000 M Series kit (Circular connector) b MIL flat cable connector reduces installation labor for electrical connection. b Manifold and connectors, both compliant with the IP65 rating (Dust-tight, Water-jet-proof), provide a high-degree of protec- tion for the electrical parts. b ...

Page 53

VV5Q21 The total number of stations is tabulated starting from station one on the D-side. How to Order Valves Series 2 VQ2000 Function Type of actuation Symbol Specifications 1 2-position single Nil Standard 2 2-position ...

Page 54

VQ2000 M Series kit (Circular connector) VV5Q21 Made by CONINVERS GmbH HC-26P1NRAWF00 73.5 <77.5> 29.5 (12) 13 73.7 Dimensions 109.5 125.5 141.5 L2 132.5 148.5 164.5 (L3) 162.5 175 187.5 (L4) 173 185.5 198 ...

Page 55

Sub-plate Single Unit VQ2000 Only Series IP65 enclosure in standard specifications Easy-to-use terminal block Terminal block Dimensions 2 x 4.5 ø (Mounting hole) Manual override Indicator light G 3/8 Electrical entry < >: AC Note) When using this valve for ...

Page 56

VQ1000/2000 Series Semi-standard Different Number of Connector Pins F and P kits with the following number of pins are available besides the standard number (F = 25P 26P). Select the desired number of pins and cable length from ...

Page 57

Special Wiring Specifications In the internal wiring of F/P/J/G/T/S kit, double wiring (connected to SOL. A and SOL adopted for each station regardless of the valve and option types. Mixed single and double wiring is available as an ...

Page 58

VQ1000/2000 Series Semi-standard External Pilot Specifications When the supply air pressure is lower than the required minimum operating pressure (0.1 to 0.2 MPa) for the solenoid valve (or when the valve is used for vacuum), specify an external pilot model. ...

Page 59

58 ...

Page 60

VQ1000/2000 Series Construction VQ1000 Plug-in Unit: Main Parts/Replacement Parts Metal seal VQ1100 (A) ( (R1) (P) (R2 VQ1200 (A) ( (R1) (P) (R2) ...

Page 61

VQ2000 Plug-in Unit: Main Parts/Replacement Parts Metal seal VQ2100 (A) ( (R1) (P) (R2 VQ2200 (A) ( (R1) (P) (R2 ...

Page 62

Exploded View of Manifold VQ1000 Plug-in Unit: Exploded View (F/P/J/L/S kit) Housing assembly D-side end plate and SI unit assembly Manifold block assembly ! U-side end plate assembly ...

Page 63

Assembly and SI Unit> Housing assembly and SI unit no. No. Manifold Part no. (SF1 kit) EX120-SUW1(-XP) (SH kit) EX120-SUH1(-XP) (SJ1 kit) EX120-SSL1(-XP) (SJ2 kit) EX120-SSL2(-XP) q (SQ kit) EX120-SDN1 (SR1 kit) EX120-SCS1(-XP) (SR2 kit) EX120-SCS2(-XP) (SV kit) EX120-SMJ1(-XP) ...

Page 64

Exploded View of Manifold VQ2000 Plug-in Unit: Exploded View (F/P/J/L/G/S kit) Housing assembly D-side end plate and SI unit assembly Manifold block assembly ! U-side end plate ...

Page 65

Assembly and SI Unit> Housing assembly and SI unit no. No. Manifold Part no. (SF1 kit ) EX120-SUW1(-XP) Note 1) (SH1 kit ) EX120-SUH1(-XP) Note 1) (SJ1 kit ) EX120-SSL1(-XP) Note 1) (SJ2 ) kit EX120-SSL2(-XP) Note 1) q ...

Page 66

VQ1000 Series VQ1000: Manifold Optional Parts Blanking plate assembly JIS symbol VVQ1000-10A used by attaching on the manifold block for being prepared for removing a valve for maintenance rea- sons or planning to mount a spare valve, etc. ...

Page 67

EXH block base assembly F VVQ1000-19A- -(C3/C4/C6/M5/N1/N3/N7 Manifold block assembly Electrical entry F0 Without lead wire For F kit ( stations)/Double wiring F1 F2 For F kit ( stations)/Double wiring F3 For F kit ...

Page 68

VQ1000 Series VQ1000: Manifold Optional Parts DIN rail mounting bracket [-D/-D0/-D„] VVQ1000-57A It is used for mounting a manifold on a DIN rail. When ordering this option incorporated with a mani- fold, suffix “D” to the end of the manifold ...

Page 69

Double check block (Separated) for VQ1000 VQ1000-FPG-„„-„ used on the outlet side piping to keep the cylinder in the intermediate position for a long time. Combining the double check block with a built-in pilot type double check valve ...

Page 70

VQ1000 Series VQ1000: Manifold Option/With Ejector Unit An ejector unit can be mounted on the manifold base for a solenoid valve. Instead of mounting the valve and ejector unit separately, this option reduces piping, wiring and creates additional space savings. ...

Page 71

How to Order Ejector Valves VVQ1000 Symbol Specifications Nil Standard High-speed B response type High-pressure type K (0.8 MPa) Negative N common Note 1) For power consumption of AC type, refer to page 16. Note 2) When two or more ...

Page 72

VQ2000 Series VQ2000: Manifold Optional Parts JIS symbol Blanking plate assembly VVQ2000-10A used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Individual ...

Page 73

SUP stop valve spacer VVQ2000-24A-1 A SUP stop valve spacer is mounted on a manifold block, making it possible to individually shut off supply air to each valve. Enclosure: Dust-tight, Water-jet-proof (IP65) compliant Back pressure check valve assembly [-B] VVQ2000-18A ...

Page 74

VQ2000 Series VQ2000: Manifold Optional Parts DIN rail mounting bracket [-D/-D0/-D„] VVQ2000-57A It is used for mounting a manifold on a DIN rail. When ordering this option incorporated with a mani- fold, suffix “-D” to the end of the manifold ...

Page 75

Manifold Option Double check block (Separated) for VQ2000 VQ2000-FPG-„„-„ mounted on the outlet side piping to keep the cylinder in the intermediate position for a long time. Combining the double check block with a 3-position exhaust center solenoid ...

Page 76

VQ2000 Series Manifold Option Double check block (Direct mounting VVQ2000-23A mounted directly on the manifold to keep the cylinder in the intermediate position for a long time. Combining the double check block with a ...

Page 77

...

Page 78

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be ...

Page 79

Safety Instructions 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or ...

Page 80

VQ1000/2000 Series Specific Product Precautions 1 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions. Light/Surge Voltage Suppressor Caution The ...

Page 81

VQ1000/2000 Series Specific Product Precautions 2 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions. Manual Override Warning Slide locking ...

Page 82

... The minimum order quantity is 10 pcs. Remove the cover from the top of the end plate and remove the old element with a flat head screwdriver, etc. (a) Refer to Best Pneumatics No. q for obtaining the flow rate. Built-in Silencer Element Element part no. VQ1000 VQ2000 VVQ1000-82A-1 ...

Page 83

...

Page 84

... Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com © 2009 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. NETHERLANDS SMC Pneumatics B.V. ...

Related keywords