RMC50A-2-N Cosel U.S.A. Inc., RMC50A-2-N Datasheet

no-image

RMC50A-2-N

Manufacturer Part Number
RMC50A-2-N
Description
Power Supply; 85 to 132 VAC/110 to 170 VDC; Multiple; 5 V; 15 V; -15 V; 50 W
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of RMC50A-2-N

Brand/series
RMC Series
Configuration
Enclosed
Current, Input
1.5 A (Typ.)
Current, Inrush
30 A (Typ.)
Current, Output
0 to 5 A
Efficiency
70% (Typ.)
Line Regulation
20 mV (Max.)
Load Regulation
40 mV (Max.)
Mounting Type
Panel
Number Of Outputs
3
Operation
Linear
Output
-15 VDC @ 0.5 A, +5 VDC @ 5 A, +15 VDC @ 1.2 A
Output Type
Multiple
Power, Output
50.5 W
Power, Rating
50 W
Primary Type
AC-DC
Standards
UL Recognized
Voltage, Input
85 to 132/110 to 170 VAC/VDC
Voltage, Output
-15, +5, +15 VDC
Voltage, Output 1
5 V
Voltage, Output 2
15 V
Voltage, Output 3
-15 V
Lead Free Status / Rohs Status
RoHS Compliant part
Home
RMC50A
Model
RMC50A-1
RMC50A-2
> Product Details
AC 85 - 132
AC 85 - 132
DC 110 -
DC 110 -
Voltage
Input
[V]
170
170
Wattage
Output
[W]
50.5
49
-12 - 12V
(peak 2A)
-15 - 15V
Output
0.5 - 5A
0.5 - 5A
[V/A]
DC
Features
Safety Agency Approvals
EMI Compliance
3 year warranty(refer to Instruction Manual)
V1 isolated from V2 and V3
Small and compact size
Built-in Inrush Current Protection
Stabilized output voltage (V1, V2, V3)
Built-in Over Current Protection
Built-in Over Voltage Protection
RoHS Compliant
Complies with DEN-AN
UL1950, C-UL
FCC-B
VCCI-B

Related parts for RMC50A-2-N

RMC50A-2-N Summary of contents

Page 1

... Output Voltage Wattage Model [V] [W] DC 110 - RMC50A-1 170 132 DC 110 - RMC50A-2 170 50 132 Features V1 isolated from V2 and V3 Small and compact size Built-in Inrush Current Protection Stabilized output voltage (V1, V2, V3) Built-in Over Current Protection Built-in Over Voltage Protection RoHS Compliant Safety Agency Approvals ...

Page 2

... CONDUCTED NOISE REGULATIONS CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 Peak load current of V2 for RMC50A-1 is possible to draw 30 seconds. *2 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). * Series/Parallel operation with other model is not possible. * When units are operated with chassis and cover, derating is required. ...

Page 3

... External view Connector type Performance data ¡ STATIC CHARACTERISTICS (RMC50A-1) ¡ OVERCURRENT CHARACTERISTICS (RMC50A-1) Barrier strip type ¡ RISE TIME & FALL TIME (RMC50A-1) ¡ DERATING CURVE RMC50A B-29 RMC ...