LY1N-AC110/120 Omron Automation, LY1N-AC110/120 Datasheet

no-image

LY1N-AC110/120

Manufacturer Part Number
LY1N-AC110/120
Description
RELAY; E-MECH; GEN PURP; SPDT; CUR-RTG 15A; CTRL-V 110/120AC; VOL-RTG 250/125AC/DC
Manufacturer
Omron Automation
Datasheet

Specifications of LY1N-AC110/120

Contact Form
SPDT
Current, Rating
15 A
Function
General Purpose
Mounting Type
Bracket
Number Of Pins
8
Power, Rating
1700⁄360 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE
Termination
Plug-In
Voltage, Control
115 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
• Arc barrier equipped.
• High dielectric strength (2,000 VAC).
• Long dependable service life assured by Ag-Alloy contacts.
• Choose models with single or bifurcated contacts,
• All models meet UL and CSA
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., LY1-DC6).
Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative.
Standard
LED indicator
Diode surge
suppression
LED indicator
and diode surge
suppression
RC circuit
LED indicator
and RC circuit
LED indicator, diode surge suppression,
push-to-test button, or RC circuit.
approvals; VDE, LR, and SEV
approved versions are available.
General Purpose Relay
LY
2. To order connecting sockets and mounting tracks, see “Accessories” section.
Type
Plug-in/solder
PCB
Plug-in/solder
Terminal
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
4PDT
SPDT
DPDT
SPDT
DPDT
Contact
form
LY1
LY2
LY3
LY4
LY1-0
LY2-0
LY3-0
LY4-0
LY1N
LY2N
LY3N
LY4N
LY1-D
LY2-D
LY3-D
LY4-D
LY1N-D2
LY2N-D2
LY4N-D2
LY1-CR
LY2-CR
LY1N-CR
LY2N-CR
mounting
Standard
bracket
Single contact
LY1F
LY2F
LY3F
LY4F
mounting
bracket
Upper
LY1S
LY2S
LY3S
LY4S
mounting
bracket
Lower
General Purpose Relay
Model
LY2Z
LY2Z-0
LY2ZN
LY2Z-D
LY2ZN-D2
LY2Z-CR
LY2ZN-CR
mounting
Standard
bracket
Bifurcated contact
LY2ZF
mounting
bracket
Upper
LY
LY2ZS
mounting
bracket
Lower
1

Related parts for LY1N-AC110/120

LY1N-AC110/120 Summary of contents

Page 1

... LY4-D — — LY1N-D2 — — LY2N-D2 — — LY4N-D2 — — LY1-CR — — LY2-CR — — LY1N-CR — — LY2N-CR — — Model Bifurcated contact Lower Standard Upper bracket mounting mounting bracket mounting bracket — — — ...

Page 2

Type Terminal Push-to-test Plug-in/solder SPDT button DPDT 3PDT 4PDT LED indicator and Plug-in/solder DPDT push-to-test button 4PDT Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative order connecting sockets and mounting ...

Page 3

Specifications ■ Contact Data Load SPDT Resistive load (p. Rated load 110 VAC 110 VAC VDC VDC Contact material Ag-Alloy Carry current 15 A ...

Page 4

Type – AC Rated Rated current (mA) voltage (V) resistance 310 270 6.70 12 159 134 100 410 100/110 15.90/18.30 13.60/15.60 2,300 120 17.30 14.8 2,450 200/220 ...

Page 5

Characteristics Contact resistance Operate time Release time Operating frequency Mechanically Under rated load Insulation resistance Dielectric strength Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating Humidity Service Life Mechanically Electrically Weight Note: Data shown ...

Page 6

Dimensions Unit: mm (inch) ■ Relays LY1 LY3 LY1-0, LY2-0, LY3-0, LY4-0 Note: The above drawing shows LY2-0. With LY1-0, dimension “*” should read as eight 6.35 (.25). LY1F, LY2F Note: The above drawing shows LY1F. With LY2F, dimension “*” ...

Page 7

LY4F LY1S, LY2S Note: The above drawing shows LY2S-US. With LY1S-US, dimension “*” should read as eight 2.03 mm (0.08 in) dia. holes. LY3S LY4S Mounting holes Round hole Rectangular hole Round hole Rectangular hole Round hole Rectangular hole General ...

Page 8

Accessories Unit: mm (inch) Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928) PTF08A Terminal arrangement/ (see note 3) mounting holes (Top view) Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928) PTF14A Terminal arrangement/ ...

Page 9

Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT14 Terminal arrangement (Bottom view) Note: Values in brackets for LY❏CR. Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT08QN Panel cut-out and terminal arrangement are ...

Page 10

Unit: mm (inch) Relay hold-down clips PYC-A1 For PTF❏A socket Relay hold-down clips PYC-P2 For push-to-test button type with PT❏ socket Mounting track/end plate/spacer PFP-100N/PFP-50N mounting track 10 General Purpose Relay PYC-S For relay mounting plates (Applicable to Type PYP-1 ...

Page 11

PFP-100N2 mounting track *This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N. **L = Length PFP-50N L = 497.84 mm (19.60 in) PFP-100N L = ...

Page 12

Relay Options LED Indicator Specifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current is approxi- mately 0 to 5.0 mA higher than the Standard Type. Terminal arrangement/Internal connections ...

Page 13

Relay Options RC Circuit Specifications and dimensions same as the Standard Type with the following exceptions. Characteristic Data Without RC circuit LY1-CR, LY2(Z)-CR Note: 1. The above drawing shows LY2(Z)-CR. With LY1-CR, “*” should read eight 2.03 mm (0.08 ...

Page 14

Approvals UL Recognized Type (File No. E41643) Type Contact form LY❏ SPDT LY❏ DPDT LY❏ 3PDT 4PDT CSA Certified Type (File No. LR31928) Type Contact form LY❏ SPDT LY❏ DPDT LY❏ 3PDT 4PDT VDE Approved Type (File No. 9903 ...

Page 15

Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer ...

Page 16

Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any stan- dards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. ...

Related keywords