119105-01 AMETEK, 119105-01 Datasheet

no-image

119105-01

Manufacturer Part Number
119105-01
Description
Blower; 242 CFM (Max.); BLDC Bypass Blower; 120; 10 A (RMS) (Max.); 0 to degC
Manufacturer
AMETEK
Type
Canisterr
Datasheet

Specifications of 119105-01

Air Flow
242 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Electrical
Current, Rating
10 A
Diameter, Inlet
2.75 "
Diameter, Outlet
2.5 "
Dimensions
145Dia x 138.68L mm
Power, Rating
800 W
Special Features
Speed Control
Static Pressure
29 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
120 VAC
Weight
6 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
60
5.7” (145mm) BLDC Bypass Blower
800 Watt, 120 Volt High Flow – IntelliGen
“E”
INCH
(MM)
NOTES:
OPERATING PARAMETERS:
• Input Voltage Range: 120 Volt AC Models: 92 to 132 VAC RMS, 50/60 Hz, single phase, maximum running current 10 Amps RMS.
• Isolated Speed Control:
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).
• Speed Control Drift with Temperature:
• Operating Temperature: 0°C to 50°C.
• Storage Temperature: -40°C to 85°C.
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage max.
• Approximate Weight: 6 lbs.
SEE DETAIL
(70.87±2.03)
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
2.79±.08
Stages
Vacuum, Maximum
(Sealed Vacuum)
Pressure, Maximum
(Sealed Pressure)
Flow Rate, Maximum
(Open Flow)
Inlet/Outlet Diameter
Dimension “D” above)
Length
(Dimension “I” above)
Length
(Dimension “L” above)
Note: Although this unit contains a lockout feature that detects low voltage conditions, the electronics should not be operated continuously below the input
voltage range listed above.
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+12 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.
Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
Analog Mode: Typ. +/-4% from nominal speed at +23°C.
Digital or Direct Mode: Typ. +/-4% from nominal speed at +23°C.
Note: Internal electronic controller is thermally protected.
CONTROL
49°±2°
OR
SPEED
-B-
L C
“M”
Blower Data
26°±2°
ACCESS FOR
MECHANICALLY
ADJUSTED SPEED
SEE VIEW
33°
(60.97)
2.40
CONTROL
“B”
VIEW “B”
EXHAUST
(35.05)
REF.
1.38
(1)
AIR
USE THIS HOLE FOR
GROUNDING OR EARTHING.
REFER TO APPROPRIATE
LISTING OR REGULATORY
AGENCY FOR PROPER
METHOD OF GROUNDING
OR EARTHING.
Ø
LOCATED AS SHOWN ON
Ø
.168±.003
(4.27±.07)
(162.56)
Ø.024/(.61) A
6.400
(83.57±1.52)
3.29±.06
Unit of Measure
BOLT CIRCLE.
HOLE THRU,
M
S
in. H
in. H
inches
inches
inches
mBar
mBar
m
CFM
mm
mm
mm
3
/hr
2
2
O
O
(26.42)
1.04
“L”
.015/(.38)
119102 M* / 119101 E*
-B-
134.62
44.45
11.94
1.75
5.30
102
168
285
.47
37
92
41
1
1
2
3
4
5
POST HEADER ASSEMBLY
(1.3)
.05
“I”
INTAKE
DETAIL
High Flow
-A-
MAX. BOW
TYP. BOTH
ENDS
(22.35±3.3)
GROUND (
AC INPUT VOLTAGE
Ø
NOT USED
NOT USED
AIR
.88±.13
(149.4)
5.88
“M”
MAX.
"D"
119104 M* / 119103 E*
)
2
Part Number
"D"
1
161.29
44.45
38.86
1.75
1.53
6.35
167
194
131
222
1
2
3
4
5
67
78
2
(95.0)
3.74
POST HEADER ASSEMBLY
(3) Ø
LOW (-)
HIGH (+)
GROUND (
AC INPUT VOLTAGE
DETAIL
LOCATED AS SHOWN ON
Ø
45°
(165.1)
.168±.003
(4.27±.07)
6.500
Ø.024/(.61) A
}
“E”
ISOLATED SPEED
CONTROL INPUT
BOLT CIRCLE.
)
HOLES THRU,
M
(2X)
90°
S
Ultra Flow
69.85/63.50
119105 E*
2.75/2.50
138.68
18.03
5.46
226
384
.71
26
64
29
72
1

Related parts for 119105-01

119105-01 Summary of contents

Page 1

... NOT USED HIGH (+) 1 GROUND ( ) GROUND ( ) 2 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE 4 5 “M” “E” DETAIL DETAIL POST HEADER ASSEMBLY Part Number High Flow Ultra Flow 119104 M* / 119103 E* 119105 167 194 72 131 226 222 384 1.75 2.75/2.50 44.45 69.85/63.50 1.53 .71 38.86 18 ...

Page 2

... AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi ...

Related keywords