GLM65-24 SL Power ( Ault / Condor ), GLM65-24 Datasheet

no-image

GLM65-24

Manufacturer Part Number
GLM65-24
Description
Power Supply, Switcher; 65 W; Multiple; 24 V; 2.7 A (Max.); 90 to 264 VAC;
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GLM65-24

Brand/series
GLM65 Series
Configuration
Open-Frame
Current, Inrush
The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37A.
Current, Output
2.7 A (Max.)
Dimensions
5 in. L x 3 in. H
Hold Time
20 ms from loss of ac input at 65 W load, from 120 Vac input.
Mounting Type
Panel
Noise, Output
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load terminated with 0.1 μF capacitor.
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 2.7 A
Output Type
Multiple
Overvoltage Protection
Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit.
Power Rating
65 W
Power, Output
65 W
Primary Type
AC-DC
Regulation, Total
2
Special Features
High Efficiency
Standards
CE Marked
Voltage, Input
90 to 264 VAC
Voltage, Output
24 VDC
36
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at minimum output voltage and
output overload will be less than 1.7 A. Meets input
current harmonic requirements of IEC1000-3-2.
Output Power
Normal continuous output power is 65 W, 75 W peak for
60 s. The 3.3 Vdc unit is 36.3 W and the 5 Vdc unit is 55 W
continuous.
Hold-Up Time
20 ms from loss of ac input at 65 W load, from 120 Vac
input.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with scope probe directly across output
terminals of the power supply with load terminated with
0.1 µF capacitor.
Transient Response
Main output: 500 µs typical response time for return to
within 0.5% of final value for a 50% load step within the
regulation limits of minimum and maximum load,
Δi/Δt<0.2 A/µs. Maximum voltage deviation is 3.5%.
Startup/shutdown overshoot less than 3%.
Voltage Adjustment
Adjustable potentiometer capable of ±5% change from
nominal setting.
Efficiency
82 to 94% minimum at full rated load, nominal input
voltage, depending on model.
GLC65
65 Watt Single Output Global Performance Switchers
Commercial/GLM65 Medical
Inrush Current
Inrush is limited by internal thermistor. The inrush at 240
Vac, averaged over the first ac half-cycle under cold start
conditions will not exceed 37A.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC65 EN55022 Class B; FCC Class B
Conducted Emissions GLM65 EN55011 Class B: FCC Class B
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
Under normal conditions, leakage current is 425 µA with
132 Vac @ 60 Hz input.
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No.
950, IEC950 and EN60950.
Medical Leakage Current
The maximum leakage current under single-fault condi-
tions (254 Vac @ 50 Hz) is 120 µA. Under normal
conditions, leakage current is 31µA with 132 Vac @ 60 Hz
input.
Medical Safety
All GLM models are approved to UL2601, CSA22.2 No.
601, IEC601-1 and EN60601. Consult factory for approval
status.
FEATURES:
• 4.1 W/in
• Compact (3.0" x 5.0" x 1.06")
• Ultra-high efficiency (up to 94%) using patented
• Meets harmonic requirements of IEC1000-3-2, Class A
• Conducted EMI exceeds FCC Class B and CISPR 22
• 2-year warranty
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, IEC950, EN60950,
• Medical Approved to UL2601, EN60601, CSA22.2
• Multiple output versions also available
technology
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
CSA22.2 No. 950
No. 601.1
marked to LVD
3
COMPLIANCE LEVEL
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.

Related parts for GLM65-24

GLM65-24 Summary of contents

Page 1

... EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC65 EN55022 Class B; FCC Class B Conducted Emissions GLM65 EN55011 Class B: FCC Class B Static Discharge EN61000-4- contact air RF Field Susceptibility EN61000-4-3, 3 V/meter Fast Transients/Bursts ...

Page 2

... GLC65 Commercial/GLM65 Medical Commercial Model Medical Model Output GLC65-5 GLM65-5 5.1 V GLC65-12 GLM65- GLC65-15 GLM65- GLC65-18 GLM6518 18 V GLC65-24 GLM65- GLC65-28 GLM65- GLC65-48 GLM65- GLC65/GLM65 MECHANICAL SPECIFICATIONS Watt Single Output Current Total Regulation V1 Adjustment ±5% 5 ±5% 4 ±5% 3 ±5% 2 ±5% 2 ±5% 1. ± ...

Related keywords