H3JA-8C AC100-120 60S Omron Automation, H3JA-8C AC100-120 60S Datasheet

no-image

H3JA-8C AC100-120 60S

Manufacturer Part Number
H3JA-8C AC100-120 60S
Description
Timer; 5 A @ 250 VAC; 6 to 60 Sec.; Plug-In/8 Pin Octal; DPDT; Knob; -10
Manufacturer
Omron Automation
Datasheet

Specifications of H3JA-8C AC100-120 60S

Contact Configuration
DPDT
Dielectric Strength
2000 VAC, 50⁄60 Hz for 1 Min Between Current-Carrying and Non-Current-Carrying Parts, and Between Contact-Carrying and Control Circuit, and Between Contacts of Different Poles, 1000 VAC, 50⁄60 Hz for 1 Min Between Non-Continuous Contacts
Function
Timing
Material, Body
Plastic Case
Temperature, Operating, Minimum
-10
Supply Voltage
100-120 VAC/200-240 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Economical, Compact, Plug-in Timer
• Time limit, ON-delay, operation with automatic resetting.
• DIN size (36 x 36 mm), fits standard 8-pin sockets.
• Wide choice of supply voltages:
• Dual LED indication for power and output status.
• Large transparent setting knob.
• Setting error rating almost matches that of a 48 x 48 timer.
• Conforms to UL and CSA, and meets CE marking
Ordering Information
Stock Note: Shaded models are normally stocked.
Note: Specify the model number, supply voltage, and rated time when ordering.
Ex. H3JA-8A 100 to 120 VAC 1 s
Time-limit operation/
self-resetting
24, 100 to 120, 200 to 240 VAC, 12, 24 VDC.
requirements.
Solid-state Timer
H3JA
Operation/resetting
system
SPDT
DPDT
Time-limit contact
Rated time
Supply voltage
Surface mounting, flush
mounting, and DIN track
mounting
Mounting method
1 s, 3 s, 5 s, 10 s, 30 s, 60 s,
3 min, 5 min, 10 min, 30
min, 60 min, 3 hrs
1 s, 3 s, 5 s, 10 s, 30 s, 60 s,
3 min, 5 min, 10 min, 30
min, 60 min, 3 hrs
Rated time
Solid-state Timer
H3JA-8A
H3JA-8C
H3JA
Model
1

Related parts for H3JA-8C AC100-120 60S

H3JA-8C AC100-120 60S Summary of contents

Page 1

... Time-limit contact system Time-limit operation/ SPDT self-resetting DPDT Note: Specify the model number, supply voltage, and rated time when ordering. Ex. H3JA-8A 100 to 120 VAC 1 s Mounting method Surface mounting, flush mounting, and DIN track mounting Rated time Supply voltage Rated time ...

Page 2

... VAC (50/60 Hz); 24 VDC; 12 VDC (only available on H3JA-8A model) 85% to 110% of rated supply voltage H3JA-8A 100 to 120 VAC: Approx (1 120 VAC 200 to 240 VAC: Approx (1 240 VAC 24 VAC: Approx. 1 VAC 24 VDC: Approx ...

Page 3

... Immunity Burst: EN61000-4- power port and output port (level control port with capacitive clamp (level 3) Immunity Surge: EN61000-4- common mode (level differential mode (level 3) UL508, CSA C22.2 No. 14, conforms to EN61812-1 Light gray (Munsell 5Y7/1) IP40 (panel surface) H3JA-8A: Approx H3JA-8C: Approx H3JA Solid-state Timer 3 ...