HS9Z-A66 IDEC Corporation, HS9Z-A66 Datasheet
HS9Z-A66
Specifications of HS9Z-A66
Related parts for HS9Z-A66
HS9Z-A66 Summary of contents
Page 1
... Door Interlock Switches HS6E Subminiature Interlock Switches with Solenoid HS6E features: • Compact body: 75 × 15 × 15-mm-wide, thinnest solenoid type interlock switch in the world. • Reversible mounting and angled cable allow four actuator insertion directions. • Energy saving. 24V DC, 110 mA (solenoid: 100 mA, LED: 10 mA) • ...
Page 2
... The retention force of HS9Z-A62S actuator is 500N maximum. HS9Z-A62S Do not apply excessive load. HS9Z-A65 The HS9Z-A65 and HS9Z-A66 have their metal actuator installed in opposite directions. Select actuator by determining the required moving direction in consideration of the door and interlock switch. See pages 370 and 373 for more information. ...
Page 3
... Door Interlock Switches Specifi cations UL 508 (UL listed), CSA C22.2, No. 14 (c-UL listed), ISO 14119 IEC 60947-5-1, EN 60947-5-1 (TÜV approval), EN 1088 (TÜV approval), Conforming to Standards GS-ET-19 IEC 60204-1/EN 60204-1 (applicable standards for use) Operating Temperature –25 to +50°C (no freezing) Storage Temperature – ...
Page 4
... Inductive load (AC15) 1A Resistive load (DC12) 2A 0.4A Inductive load (DC13) 1A 0.22A Resistive load (AC12) 2.5A 1.5A – Inductive load (AC15) 1.5A 0.75A Resistive load (DC12) 2.5A 1.1A 0.55A Inductive load (DC13) 2.3A 0.55A 0.27A www.idec.com Door Interlock Switches – – ...
Page 5
... Canada: 888-317-IDEC HS6E Series 3-M4 Screw (ø4 tapped hole) 28.5 41 Hole for Manual Unlocking ø12 (reference) 28.5 41.8 When using horizontal/vertical angle adjustable actuator (HS9Z-A65/A66) (25) 22.6 ±1 Actuator Stop (supplied) Interlock Switch Actuator Stop HS9Z-A61 Actuator Door Stop Door Stop 369 ...
Page 6
... When mounted (5) 14 Rubber Bushing 1.2 (Note) Actuator Stop (supplied) Angle Adjustable Actuator (HS9Z-A66) The HS9Z-A65 and HS9Z-A66 have the metal actuator inserted in opposite direc- tions. Horizontal Adjustment Angle Adjustment (M3 Hexagon Socket Head Screw) Vertical Adjustment 2 Angle Adjustment ...
Page 7
... Lock Monitor Circuit (unlocked, NO) Lock Monitor Circuit (locked, NC) The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A65, and -A66 actuators. For the HS9Z-A62S actuator, subtract 0.6 mm. The characteristics show the contact status when the actuator enters an entry slot of an interlock switch. ...
Page 8
... Lock Monitor Circuit (unlocked, NO) Lock Monitor Circuit (locked, NC) The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A65, and -A66 actuators. For the HS9Z-A62S actuator, subtract 0.6 mm. The characteristics show the contact status when the actuator enters an entry slot of an interlock switch. ...
Page 9
... When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A65 and HS9Z-A66). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation ...
Page 10
... When installing the HS9Z-A62S actuator, use the mounting plate (supplied with the actuator) on the hinged door, and secure the actuator tightly using Manual Unlocking two M4 screws. ...
Page 11
... Door Interlock Switches Wire Identifi cation • Wires can be identifi color and or a white line printed on the wire. No. Insulation Color No. 1 Blue/White 7 2 Gray 8 3 Pink 9 4 Orange 10 5 Orange/White 11 6 Gray/White 12 Terminal Number Identifi cation • When wiring, identify the terminal number of each contact by the color of the insulation. • ...
Page 12
... Door Hinge HS2B Precautions • Cracks or burrs on the conduit entry may deteriorate the housing protection against water. • When changing to another conduit port, close the unused opening with an optional plug (Part No. HS9Z-P1). USA: 800-262-IDEC Canada: 888-317-IDEC Precautions Door Hinge Door Hinge 397 ...
Page 13
... Cracks or burrs on the conduit entry may deteriorate the housing protection. • When changing to the other conduit port, close the unused opening with an optional plug (accessory). Type No. HS9Z-P1 Manual Unlocking • Remove the screw located on the unlocking entry at the side of the switch us- ing the key wrench included with the switch ...
Page 14
... M4 Phillips screws) The screws are supplied by the user. Applicable Wire Size • HS1C: 0.5 to 0.75 mm 1.0 to 1.25 mm • HS5B: 0.5 to 1.25 mm • HS1E: 0.5 to 1.25 mm HS9Z-A1 Actuator USA: 800-262-IDEC Canada: 888-317-IDEC Precautions (PF13.5): RBC-103PG13.5 G1 max. (Terminals No. (Terminals No.3, 4, and grounding terminal) ...
Page 15
... When the door hinge is on the extension line of the interlock switch surface: Door Hinge • When door hinge is on the extension line of the actuator mounting surface: Door Hinge When using the HS9Z-A55 Angle Adjustable Actuator • When door hinge is on the extension line of the interlock switch surface • ...