PIC18F45K22-I/P Microchip Technology Inc., PIC18F45K22-I/P Datasheet - Page 248

no-image

PIC18F45K22-I/P

Manufacturer Part Number
PIC18F45K22-I/P
Description
40 PDIP .600in TUBE, 32KB, Flash, 1536bytes-RAM, 8-bit Family, nanoWatt XLP
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC18F45K22-I/P

A/d Inputs
28-Channel, 10-Bit
Comparators
2
Cpu Speed
16 MIPS
Eeprom Memory
256 Bytes
Input Output
35
Interface
I2C/SPI/UART/USART
Memory Type
Flash
Number Of Bits
8
Package Type
40-pin PDIP
Programmable Memory
32K Bytes
Ram Size
1.5K Bytes
Speed
64 MHz
Temperature Range
–40 to 125 °C
Timers
3-8-bit, 4-16-bit
Voltage, Range
1.8-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F45K22-I/P
Manufacturer:
MICROCHIP
Quantity:
3 400
Part Number:
PIC18F45K22-I/P
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F45K22-I/PT
Manufacturer:
SST
Quantity:
3 400
Part Number:
PIC18F45K22-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18F45K22-I/PT
Manufacturer:
MIC
Quantity:
20 000
Part Number:
PIC18F45K22-I/PT
0
Company:
Part Number:
PIC18F45K22-I/PT
Quantity:
20 400
PIC18(L)F2X/4XK22
15.6.13
Multi-Master mode support is achieved by bus
arbitration. When the master outputs address/data bits
onto the SDAx pin, arbitration takes place when the
master outputs a ‘1’ on SDAx, by letting SDAx float high
and another master asserts a ‘0’. When the SCLx pin
floats high, data should be stable. If the expected data
on SDAx is a ‘1’ and the data sampled on the SDAx pin
is ‘0’, then a bus collision has taken place. The master
will set the Bus Collision Interrupt Flag, BCLxIF, and
reset the I
If a transmit was in progress when the bus collision
occurred, the transmission is halted, the BF flag is
cleared, the SDAx and SCLx lines are deasserted and
the SSPxBUF can be written to. When the user
services the bus collision Interrupt Service Routine and
if the I
communication by asserting a Start condition.
FIGURE 15-32:
DS41412D-page 248
SDAx
SCLx
BCLxIF
2
C bus is free, the user can resume
2
C port to its Idle state
MULTI -MASTER COMMUNICATION,
BUS COLLISION AND BUS
ARBITRATION
BUS COLLISION TIMING FOR TRANSMIT AND ACKNOWLEDGE
Data changes
while SCLx = 0
(Figure
15-31).
Preliminary
SDAx released
by master
SDAx line pulled low
by another source
If a Start, Repeated Start, Stop or Acknowledge
condition was in progress when the bus collision
occurred, the condition is aborted, the SDAx and SCLx
lines are deasserted and the respective control bits in
the SSPxCON2 register are cleared. When the user
services the bus collision Interrupt Service Routine and
if the I
communication by asserting a Start condition.
The master will continue to monitor the SDAx and SCLx
pins. If a Stop condition occurs, the SSPxIF bit will be set.
A write to the SSPxBUF will start the transmission of
data at the first data bit, regardless of where the
transmitter left off when the bus collision occurred.
In Multi-Master mode, the interrupt generation on the
detection of Start and Stop conditions allows the
determination of when the bus is free. Control of the I
bus can be taken when the P bit is set in the SSPxSTAT
register, or the bus is Idle and the S and P bits are
cleared.
2
C bus is free, the user can resume
Sample SDAx. While SCLx is high,
data does not match what is driven
by the master.
Bus collision has occurred.
Set bus collision
interrupt (BCLxIF)
 2010 Microchip Technology Inc.
2
C

Related parts for PIC18F45K22-I/P