48134-51 AMETEK, 48134-51 Datasheet

no-image

48134-51

Manufacturer Part Number
48134-51
Description
24 Volt Brushless DC Motor Controller
Manufacturer
AMETEK
Type
Motor/Blowerr
Datasheet

Specifications of 48134-51

Current, Input
20 A
Dimensions
92.7mmL×82.6mmW×35.6mmH
Mounting Type
Panel
Primary Type
Controller
Termination
Screw
Voltage, Supply
11 to 52 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
BLDC Motor
116
20 Amp BLDC Motor/Blower Controller
*These part numbers are available through AMETEK Technical & Industrial Products distributors.
NOTES:
• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.
• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is
• Current Control: Trip point is at 20 Amp maximum.
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings:
Maximum Continuous Current
Input Voltage Range
Controller PWM Frequency
Analog Speed Input
Electrical Hall Spacing
Waveform
Current Limit Protection
Rotation
achieved by adjusting the potentiometer when J6 is in position 1 to 2.
J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
J3-Rotations:
J5-Input Voltage:
J6-Speed Control:
INCH
(MM)
PIN 12
PIN 7
(28.5) MAX.
1.12
(35.6) MAX.
1.40
(43.2) MAX.
1.70
Controller Data
60° electrical spacing with jumper disconnected.
Clockwise rotation with jumper connected (default).
Counter-clockwise rotation with jumper disconnected.
Do not change while motor is running or damage will occur.
Position 1-2 for 16-52 VDC (default).
Position 2-3 for 11-16 VDC.
Position 1-2 for internal speed adjust, via on board potentiometer (default).
Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
PIN 6
PIN 1
MOLEX 8724 SERIES DUAL ROW SHROUDED HEADER
SQUARE PIN, .100 CENTERS, 12 CIRCUIT SEE CHART (J4)
MATES WITH MOLEX 70450 SERIES DUAL ROW CRIMP
CONNECTOR HOUSING NO. 22-56-6127 OR EQUIVALENT
PIN 1
TERMINAL
BLOCK
.197 CENTERS
#12 - #30 AWG
SEE CHART (J1)
(82.6±0.25)
3.25±.01
2X
2X
1.56±.010
2X
(4±0.25)
(4.83±0.38)
2.190±.015
(13.5±0.25)
.53±.01
J4
J1
1
J5
(84.79±0.38)
3.338±.015
1
Motor/Blower Contoller
J6
J3
C17
(92.7±0.25)
3.65±.01
6-Step Trapezoidal
J2
60° or 120°
11-28 VDC
CW / CCW
0-5 VDC
48134*
25 kHz
20 A
Yes
4X
(4.83±0.26)
.190±.010
J4-1 Ground
J4-2 Hall 1
J4-3 Hall 2
J4-4 Hall 3
J4-5 Hall +
J4-6 Brake
J4-7 Ground
J4-8 Vref
J4-9 Output Enable
J4-10 Forward/Reverse
J4-11 Tach Out
J4-12 Analog In
J1-1 Vin
J1-2 Phase A
J1-3 Phase B
J1-4 Phase C
J1-5 Ground