OMIH-SH-112D,394 TE Connectivity, OMIH-SH-112D,394 Datasheet

no-image

OMIH-SH-112D,394

Manufacturer Part Number
OMIH-SH-112D,394
Description
Relay; E-Mech; Power; SPDT; Cur-Rtg 16A; Ctrl-V 12DC; Vol-Rtg 240/30AC/DC; PCB Mnt
Manufacturer
TE Connectivity
Series
OMIHr
Datasheet

Specifications of OMIH-SH-112D,394

Brand/series
OMIH Series
Contact Form
SPDT
Current, Rating
16 A
Function
Power
Mounting Type
PCB
Power, Rating
3800⁄480 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE, SEMKO, RoHS
Termination
Solder
Tyco Part Number
6-1440000-9
Voltage, Control
12 VDC
Voltage, Rating
240 VAC
Coil Voltage
12 VDC
Contact Rating
16 A at 240 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
720 mW
Contact Material
Silver Tin Oxide
Coil Current
16 A
Coil Resistance
200 Ohms
Coil Type
Monostable
Lead Free Status / Rohs Status
RoHS Compliant part
458
Initial Insulation Resistance
Between Mutually Insulated Elements: 1,000M ohms min. @ 500VDC.
Features
• Meet UL 508, VDE0435 and SEMKO requirements.
• 1 Form A and 1 Form C contact arrangements.
• Immersion cleanable, sealed version available.
• Meet 5,000V dielectric voltage between coil and contacts.
• Meet 10,000V surge voltage between coil and contacts (1.2 / 50 s).
Contact Ratings
Ratings: OMI: 10A @ 240VAC resistive,
Max. Switched Voltage: AC: 250V.
Max. Switched Current: 10A (OMI), 16A (OMIH).
Max. Switched Power: OMI: 2,400VA, 300W.
Initial Dielectric Strength
Between Open Contacts: 1,000VAC 50/60 Hz. (1 minute).
Between Coil and Contacts: 5,000VAC 50/60 Hz. (1 minute).
Surge Voltage Between Coil and Contacts: 10,000V (1.2 / 50 s).
Contact Data @ 20 C
Arrangements: 1 Form A (SPST-NO) and 1 Form C (SPDT).
Material: Ag Alloy (OMI), AgSnO (OMIH).
Max. Switching Rate: 300 ops./min. (no load).
Expected Mechanical Life: 10 million operations (no load).
Expected Electrical Life: 100,000 operations (rated load).
Minimum Load: 100mA @ 5VDC.
Initial Contact Resistance: 100 milliohms @ 1A, 6VDC.
Coil Data
Voltage: 5 to 48VDC.
Nominal Power: 720 mW (OMI-D), 540mW (OMI-L).
Coil Temperature Rise: 45 C max., at rated coil voltage.
Max. Coil Power: 130% of nominal.
Duty Cycle: Continuous.
OMIH:16A @ 240VAC resistive,
10A @ 30VDC resistive,
16A @ 30VDC resistive,
3A @ 240VAC inductive (cosø= 0.4),
3A @ 30VDC inductive (L/R=7msec).
4A @ 240VAC inductive (cosø= 0.4),
4A @ 24VDC inductive (L/R=7msec).
30 ops./min. (rated load).
OMIH: 3,800VA, 480W.
DC: 30V.
Catalog 1308242
Issued 3-03
Mechanical Data
Termination: Printed circuit terminals.
Enclosure (94V-0 Flammability Ratings):
Weight: 0.46 oz (13g) approximately.
OMI/OMIH
16A Miniature
Power PC Board Relay
Appliances, HVAC, Office Machines.
Coil Data @ 20 C
Operate Data
Must Operate Voltage:
Must Release Voltage: 5% of nominal voltage or more.
Operate Time: OMI/OMIH-D: 15 ms max.
Release Time: 8 ms max.
Environmental Data
Temperature Range:
Operating:
Vibration, Mechanical: 10 to 55 Hz., 1.5mm double amplitude
Shock, Mechanical: 1,000m/s
Operating Humidity: 20 to 85% RH. (Non-condensing).
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Rated Coil
Rated Coil
Voltage
Voltage
(VDC)
(VDC)
12
24
48
12
24
48
UL File No. E58304
CSA File No. LR48471
VDE File No. 6678
SEMKO File No. 9517235 (OMI)
5
6
9
5
6
9
OMI/OMIH-SS: Vented (Flux-tight) plastic cover.
OMI/OMIH-SH: Sealed plastic case.
Operational: 100m/s
Operational: 10 to 55 Hz., 1.5mm double amplitude.
OMI/OMIH-L:
OMI/OMIH-D:
Nominal
Nominal
Current
Current
-30 C to +55 C
-30 C to +70 C
(mA)
(mA)
OMI/OMIH-D: 70% of nominal voltage or less.
OMI/OMIH-L: 75% of nominal voltage or less.
OMI/OMIH-L: 20 ms max.
106.4
138.9
120.0
88.0
58.0
44.4
21.8
10.9
78.3
60.0
29.3
14.5
OMI/OMIH-L Sensitive
OMI/OMIH-D Standard
(ohms)
(ohms)
9143112 (OMIH)
Resistance
Resistance
2
(10G approximately).
1,100
4,400
3,300
series
2
Coil
Coil
155
270
115
200
820
(100G approximately).
47
68
36
50
10%
10%
Must Operate
Must Operate
Voltage
Voltage
18.00
36.00
16.80
33.60
(VDC)
(VDC)
3.75
4.50
6.75
9.00
3.50
4.20
6.30
8.40
Must Release
Must Release
Voltage
Voltage
(VDC)
(VDC)
0.50
0.60
0.90
1.20
2.40
4.80
0.50
0.60
0.90
1.20
2.40
4.80
OEG

Related parts for OMIH-SH-112D,394

OMIH-SH-112D,394 Summary of contents

Page 1

... Operate Data Must Operate Voltage: OMI/OMIH-D: 70% of nominal voltage or less. OMI/OMIH-L: 75% of nominal voltage or less. Must Release Voltage nominal voltage or more. Operate Time: OMI/OMIH- max. OMI/OMIH- max. Release Time max. Environmental Data Temperature Range: Operating: OMI/OMIH-D: ...

Page 2

... D = Standard (720mW Sensitive (540mW) 6. Contact Arrangement: Blank = 1 Form C, SPDT Form A, SPST-NO 7. Suffix: ,300 = Standard model for "SS" enclosure Our authorized distributors are more likely to stock the following items for immediate delivery. OMIH-SH-105D,394 OMIH-SH-105L,394 OMIH-SH-112D,394 OMIH-SH-112L,394 OMIH-SH-124L,394 OMIH-SH-124D,394 Outline Dimensions .811 .02 (20.6 .5) .157 ...

Related keywords