OD1232-SPOT Orion (Knight Electronics, Inc.), OD1232-SPOT Datasheet

no-image

OD1232-SPOT

Manufacturer Part Number
OD1232-SPOT
Description
Fan; AC; 120 V; 19.0 W; 65 to 120 CFM; 1600 RPM; Auto Restart; Therm Control; 120x32.3mm
Manufacturer
Orion (Knight Electronics, Inc.)
Datasheet

Specifications of OD1232-SPOT

Voltage Input
120 VAC/60 Hz
Input Power
19 W
Dc Nominal Current
0.60 A
Dc Locked Current
0.05 A
Rated Speed (rpm)
1600 Max. (40°C)
Airflow (cfm)/temp
65 to 120 / 25°C to 40°C
Noise Level (db)
47
Max. Static Pressure
0.43" H2O
Bearing System
Dual Ball Bearing
Frame & Impeller
PBT, UL94V-O Plastic
Motor
Brushless DC, Auto Re-start, Polarity Protected. Thermal Control
Insulation Resistance
10 Mohm between leadwire and frame (500 VDC)
Dielectric Strength
5 mA max at 1500 VAC for 1 minute between the leadwire and frame
Operation Temperature
–10°C to +70°C
Life (l10)
60,000 HoursTools and parts required (Not supplied with this unit)
Lead Free Status / Rohs Status
RoHS Compliant part
Rating information is +/-10%
Data and specifications are subject to change without prior notification
Part No. (ENG SKU)
Fan ID
VOLTAGE INPUT
INPUT POWER
DC Nominal Current
DC Locked Current
Rated Speed (RPM)
Airflow (CFM)/Temp
Noise Level (dB)
Max. Static Pressure
Bearing System
Frame & Impeller
Connection
Motor
Bearing System
Insulation Resistance
Dielectric Strength
Operation
Temperature
Life (L10)
OD1232-SPOT
OD1232-12HB-03
120VAC / 60Hz
19 Watts
0.60 A
0.05 A
1600 Max. (40C)
65 ~ 120 / 25C~40C
47
0.43” H 2 O
Dual Ball
PBT, UL94V-O plastic
[ see installation instructions, item 4. ]
Brushless DC, auto restart, polarity pro-
tected. Thermal Control.
Dual ball bearing
10M ohm between leadwire and frame
(500VDC)
5mA max at 1500VAC for 1 minute
between the leadwire and frame
-10C ~ +70C
60,000 hours
General Notes:
A. Always ensure power is disconnected before working on or
installing this component
B. Maker assumes no responsibility for suitability of purpose in
any installation
C. Do not wear loose clothing or accessories that may become
entangled in moving parts while
assembling or operating this component.
Installation Instructions:
Tools and parts required (Not supplied with this unit):
(4x) 8-32 x 1⁄2” screws
(4x) 8-32 nut
( 1 ) G109-15A (or equivalent) 120mm finger guard
1. Cut an opening in the enclosure wall as shown in the
diagram [below]
2. Place fan [right] so that the 8-32x 1⁄2” screws pass through
the outer grill and the fan flange.
3. Place the 8-32 nut in place as shown and tighten
4. Plug 12V adaptor provided into the receptacle on the fan and
into an appropriate 120V power
source.
The fan will operate at low to medium speed and will increase
speed as more cooling is necessary in the
application.
panel cutout
Description
Thermistor
Airflow Range:
65CFM at 25C or
below ramping up to
120CFM at 40C+
Contact:
214-340-0265 (Tel)
214-340-5870 (Fax)
frame dimensions only:
adapter, cord, connector
and receptacle not shown
NOTES:
Unit Includes:
6 foot cord with
fan connector