117635-53 AMETEK, 117635-53 Datasheet

no-image

117635-53

Manufacturer Part Number
117635-53
Description
Bypass Blower, 400 Watt, 240 Volt
Manufacturer
AMETEK
Type
Canisterr
Datasheet

Specifications of 117635-53

Air Flow
90 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Mechanical
Current, Rating
5 A
Diameter, Inlet
1.75 "
Diameter, Outlet
1.75 "
Dimensions
145Dia x 184.91L mm
Power, Rating
400 W
Special Features
Speed Control
Static Pressure
61 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
240 VAC
Weight
6 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
56
5.7” (145mm) BLDC Bypass Blower
400 Watt, 240 Volt High Flow
NOTES:
• Nominal Input Voltage: 240 Volts AC RMS ±10%, 50/60Hz.
• Input Current: 5 amps AC RMS maximum.
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C.
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
• Optional: IntelliGen™ controller available for customized performance.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
Stages
Vacuum, Maximum
(Sealed Vacuum)
Pressure, Maximum
(Sealed Pressure)
Flow Rate, Maximum
(Open Flow)
Inlet/Outlet Diameter
(Dimension “D” above)
Length
(Dimension “I” above)
Length
(Dimension “L” above)
Ø
(32.0)
INCH
(MM)
1.26
MAX.
Blower Data
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to
speed adjustment.
33°
43°±2°
SEE DETAIL
USE THIS HOLE FOR
GROUNDING OR EARTHING.
REFER TO APPROPRIATE
LISTING OR REGULATORY
AGENCY FOR PROPER METHOD
OF GROUNDING OR EARTHING.
(1) Ø
THRU, LOCATED AS SHOWN
ON A
Ø.024/(.61) A
.168±.003
(4.27±.07)
Ø
(60.45)
(162.56)
2.38
6.400
“E”
OR
M
SENSITIVITY
HOLE,
CONTROL
BOLT
CIRCLE.
Unit of Measure
“M”
37°±2°
C L
S
in. H
in. H
inches
inches
inches
mBar
mBar
m
CFM
mm
mm
mm
3
/hr
2
2
O
O
ACCESS FOR MECHANICALLY
ADJUSTED SPEED CONTROL
(81.79±1.52)
3.22±.06
(15.0)
0.59
“L”
.015/(0.38)
117637 M* / 117643 E*
(26.42)
1.04
132.59
44.45
11.94
1.75
5.22
125
212
.47
23
57
25
62
1
(1.3)
“l”
.05
-A-
5
MAX. BOW
TYP. BOTH
ENDS
(22.35±3.3)
INTAKE
4
.88±.13
AIR
Ø
3
(149.4)
POST HEADER ASSEMBLY
5.88
2
DETAIL
1
117636 M* / 117642 E*
MAX.
(4)
Part Number
“E”
LOW
HIGH
GROUND
AC INPUT
(VOLTAGE 240±10%)
Ø
High Flow
EQUALLY SPACED AS SHOWN
ON A
EXHAUST
(.168±.003)
4.27±.07
"D"
Ø.024/(.61) A
}
AIR
159.26
ISOLATED SPEED
INPUT REQUIRED
"D"
44.45
38.86
2
Ø
1.75
1.53
6.27
112
102
173
39
97
45
CONTROL
2
1
(165.1)
0-10. D.C.
6.500
HOLES THRU,
M
BOLT CIRCLE.
(95.0)
3.74
47°
43°
5
4
117635 M* / 117641 E*
3
POST HEADER ASSEMBLY
2
DETAIL
(3X)
90°
1
184.91
44.45
64.26
1.75
2.53
7.28
131
151
153
“M”
53
61
90
AC INPUT
(VOLTAGE 240±10%)
NOT USED
GROUND
3
NOT USED

Related parts for 117635-53

117635-53 Summary of contents

Page 1

... INPUT REQUIRED GROUND GROUND AC INPUT AC INPUT (VOLTAGE 240±10%) (VOLTAGE 240±10%) “E” “M” DETAIL DETAIL POST HEADER ASSEMBLY POST HEADER ASSEMBLY Part Number High Flow 117636 M* / 117642 E* 117635 M* / 117641 131 45 61 112 151 102 90 173 153 1.75 1.75 44 ...

Page 2

... AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi ...

Related keywords