MMB50A-2 Cosel U.S.A. Inc., MMB50A-2 Datasheet

no-image

MMB50A-2

Manufacturer Part Number
MMB50A-2
Description
Power Supply; 85 to 132 VAC; 5 V @ 5.0 A; 12 V; 5.0` A Current, Output 1
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of MMB50A-2

Brand/series
MMB Series
Configuration
Open-Frame
Current, Input
1.4 A (Typ.)
Current, Output 1
5.0` A
Current, Output 2
2.1 A
Efficiency
72% (Typ.)
Frequency, Input
47 to 440 VAC
Mounting Type
Panel
Number Of Outputs
2
Operation
Linear
Output
+5 VDC @ 5 A, +12 VDC @ 2.1 A
Power, Output
50.2 W
Primary Type
AC-DC
Regulation, Line
20 mV (Max.) @ 5 V⁄48 mV (Max.) @ 12 V
Regulation, Load
40 mV (Max.) @ 5 V⁄100 mV (Max.) @ 12 V
Standards
UL Listed, cULus Recognized
Temperature, Operating
-10 to +65 °C
Voltage, Input
85 to 132/110 to 170 VAC/VDC
Voltage, Output
+5, +12 VDC
Voltage, Output 1
5 V @ 5.0 A
Voltage, Output 2
12 V
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMB50A-2
Manufacturer:
COSEL
Quantity:
323
Home
MMB50A
Model
MMB50A-1
MMB50A-2
MMB50A-3
MMB50A-4
MMB50A-5
MMB50A-6
> Product Details
AC 85 - 132
AC 85 - 132
AC 85 - 132
AC 85 - 132
AC 85 - 132
AC 85 - 132
DC 110 -
DC 110 -
DC 110 -
DC 110 -
DC 110 -
DC 110 -
Voltage
Input
[V]
170
170
170
170
170
170
Wattage
Output
[W]
50.2
50.4
51
51
54
51
(peak 3.6A)
(peak 1.8A)
Output
5 - 12V
5 - 12V
2.1 - 5A
5 - 24V
1.5 - 3A
1.5 - 3A
[V/A]
12V
2.1A
12V
15V
1.7A
DC
3A
Features
Safety Agency Approvals
EMI Compliance
2 year warranty(refer to Instruction Manual)
Regulated V1, V2
V1 isolated from V2
Built-in Inrush Current Protection
Built-in Over Current Protection
Built-in Over Voltage Protection
RoHS Compliant
Complies with DEN-AN
UL1950, C-UL
FCC-B

Related parts for MMB50A-2

MMB50A-2 Summary of contents

Page 1

... Home > Product Details MMB50A Input Output Voltage Wattage Model [V] [W] DC 110 - MMB50A-1 170 132 DC 110 - MMB50A-2 170 50 132 DC 110 - MMB50A-3 170 132 DC 110 - MMB50A-4 170 50 132 DC 110 - MMB50A-5 170 132 DC 110 - MMB50A-6 170 132 Features Regulated V1 isolated from V2 Built-in Inrush Current Protection ...

Page 2

... Derating is required when operated with case cover. B-14 Ordering information MMB 50A 1 MMB50A-1 MMB50A-2 MMB50A-3 +5V 3.0A +5V 5.0A +5V 3.0A +12V 3.0 ( Peak 3 +12V 2.1A +24V 1.5 ( Peak 1 +12V 2.1A MMB50A-1 MMB50A-2 MMB50A-3 AC85 - 132 DC110 - 170 47 - 440 or DC 75typ 72typ 75typ +5 +12 +5 + Peak3 ...

Page 3

... External view Connector type Performance data ¡ STATIC CHARACTERISTICS ( MMB50A-1 ) OVERCURRENT CHARACTERISTICS ( MMB50A-1 ) ¡ Barrier strip type RISE TIME & FALL TIME ( MMB50A-1 ) ¡ ¡ DERATING CURVE MMB50A B-15 MMB ...

Related keywords