H3YN-41-AC100-120 Omron Automation, H3YN-41-AC100-120 Datasheet

no-image

H3YN-41-AC100-120

Manufacturer Part Number
H3YN-41-AC100-120
Description
Relay; SSR; Timing; Multi-Function; 4PDT; Cur-Rtg 3A; Ctrl-V 100-120AC; Vol-Rtg 250AC
Manufacturer
Omron Automation
Datasheet

Specifications of H3YN-41-AC100-120

Contact Form
4PDT
Current, Rating
3 A
Display Type
LED
Function
Timing
Mounting Type
Panel
Relay Type
Solid State
Standards
UL, CSA
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
Multi-Function
Timing Range
0.1 min. to 10 hrs.
Voltage, Control
120 VAC
Voltage, Rating
250 VAC
Timing Functions
ON-Delay, Interval, Repeat Cycle (ON-Start or OFF-Start)
Supply Voltage
100-120 VAC, 200-230 VAC, 24 VAC or 24 VDC
Control Output
DPDT, 5 A @ 250 VAC (H3YN-2); 4-DDT, 5 A @ 250 VAC (H3YN-4)
Time Range
0.1 Sec. to 10 Min. (H3YN-_ ) or 0.1 Min. to 10 Hrs. (H3YN-_ 1)
Lead Free Status / Rohs Status
RoHS Compliant part
Miniature Timer with Multiple Time Ranges
and Multiple Operating Modes
• Minimizes stock.
• Pin configuration compatible with MY Power Relay.
• Standard multiple operating modes and multiple time ranges.
• Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and
Model Number Structure
■ Model Number Legend
1. Output
2. Time Range
Ordering Information
■ List of Models
Note: 1. Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately.
■ Accessories (Order Separately)
Connecting Socket
H3YN-@@-@
Note: Specify both the model number and supply voltage when ordering.
24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC
24 VDC
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
EMC Directives.
Solid-state Timer
H3YN
2: DPDT
4: 4PDT
None:Short-time range (0.1 s to 10 min)
1: Long-time range (0.1 min to 10 hrs)
2. Only models with 24-VDC power supply are available.
3. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even
smaller loads.
Supply voltage
Example: H3YN-2 24 VAC
1 2
Timer
3
PYF08A, PYF08A-N,
PYF08A-E
PYF14A, PYF14A-N,
PYF14A-E
Track-mounting/Front-
connecting Socket
DPDT
4PDT
4PDT (Twin contacts)
Supply voltage
Time-limit contact
PY08
PY14
Solder terminal
H3YN-2
H3YN-4
H3YN-4-Z
3. Contact Type
Short-time range model
None:Single contact
Z: Twin contacts
(0.1 s to 10 min)
PY08QN(2)
PY14QN(2)
Back-connecting Socket
Wire-wrap terminal
H3YN-21
H3YN-41
H3YN-41-Z
Long-time range model
PY08-02
PY14-02
(0.1 min to 10 h)
PC terminal

Related parts for H3YN-41-AC100-120

H3YN-41-AC100-120 Summary of contents

Page 1

... Note: 1. Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately. 2. Only models with 24-VDC power supply are available. 3. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even smaller loads. ...

Page 2

... Note not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. 2. Single-phase, full-wave-rectified power supplies can be used. 3. When using the H3YN continuously in any place where the ambient temperature range of 45°C to 50°C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). ...

Page 3

... Immunity Burst: EN61000-4- power-line (level 3) Immunity Surge: EN61000-4- line to ground (level 3) UL508, CSA C22.2 No. 14, Lloyds Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3YN-2/-21, 2.5 kV/1 for H3YN-4/-41, H3YN- 4-Z/-41-Z) Output category according to EN60947-5-1. H3YN 2 kV I/O signal-line (level line to line (level 3) ...

Page 4

... Mounting Height PYF08A/PYF08A-N/PYF08A-E (PYF14A/PYF14A-N/PYF14A-E (see note)) H3YN Series PYF08A (PYF14A) Note: Models in parentheses are Connecting Sockets to the H3YN-4/-41 or H3YN-4-Z/-41-Z. Eight, 3 × 1.2 elliptic holes 6.4 21.5 max. (63.0) Fourteen, 3 × 1.2 elliptic holes 21.5 max. PY08 (PY14 (see note)) ...

Related keywords