7014AB TE Connectivity, 7014AB Datasheet

no-image

7014AB

Manufacturer Part Number
7014AB
Description
Relay; Electropneumatic; Timing; On Delay; 4PDT; Ctrl-V 120/110AC; 0.7-7 sec.
Manufacturer
TE Connectivity
Datasheet

Specifications of 7014AB

Brand/series
7000 Series
Contact Form
4PDT
Current, Rating
5, 10, 15 A
Dielectric Strength
1500 V (RMS) Between Terminal and Ground
Dimensions
4.523 in. L x 2.572 in. W x 2.832 in. H
Function
Timing
Mounting Type
Panel
Relay Type
Electropneumatic
Resistance, Insulation
500 Megohms
Standards
UL, CSA, CE
Temperature, Operating
-30 to +75 °C
Termination
Screw
Timer Type
On Delay
Timing Range
0.7 to 7 sec.
Tyco Part Number
1423160-1
Voltage, Control
120⁄110 VAC
Voltage, Rating
240, 600⁄30 VAC⁄VDC
Many Enclosure Options
Explosion Proof, Dust Tight, Water Tight, Hermetically Sealed, NEMA 1
Numerous Mounting Options
Surface-Mount, Panel-Mount, Octal Plug-In Mounting
Options And Accessories
Quick-Connect Terminals, Dial Stops and Transient Protections Module
Supply Voltage
110 VAC, 120 VAC
Contact Rating
10 A at 240 VAC
Termination Style
Screw
Lead Free Status / Rohs Status
No
1248
Design Features
• Available in on-delay, true off-delay, and on/off-delay.
• Timing from 0.1 seconds to 60 minutes, in linear increments.
• Oversize time-calibrated adjustment knobs, serrated with high-resolution
• Inherent transient immunity.
• Standard voltages from 6-550VAC and 12-550VDC (special voltages available.)
• Available in 2-pole or 4-pole models.
• Numerous enclosure options:
• Auxiliary timed and instantaneous switches can be added for greater switching
• Many mounting options: Surface mount, Panel mount, Octal plug-in mounting.
• Options: quick-connect terminals, dial stops, and transient protection module.
• Easy-to-reach screw terminals, all on the face of the unit, clearly identified.
• Modular assembly - timing head, coil assembly and switchblock are all
Design & Construction
controlled pressure through a variable orifice to provide linearly adjustable
timing. Patented design provides instant recycling, easy adjustment and long
service life under severe operating conditions.
with minimum current drain. Total sealing without external leads eliminates
moisture problems, gives maximum insulation value.
mechanism provides greater contact pressure up to transfer time for
positive, no flutter action. Standard switches are DPDT arrangement, with
flexible beryllium copper blades and silver-cadmium oxide contacts. Special
"timing-duty" design assures positive wiping action, sustained contact pres-
sure and greater heat dissipation during long delay periods.
then assembled at the factory with the other two to afford a wide choice of
operating types, coil voltages, and timing ranges.
grouping of Series 7000 units side-by-side in minimum panel space.
Auxiliary switches may be added in the base of the unit, without affecting
the overall width or depth.
Operation
“On-Delay” models provide a delay period on energization, at the end of
which the switch transfers the load from one set of contacts to another. De-
energizing the unit during the delay period immediately recycles the unit,
readying it for another full delay period on re-energization.
energization, and the delay period does not begin until the unit is de-
energized. At the end of the delay period the switch returns to its original po-
sition. Re-energizing the unit during the delay period immediately resets the
timing, readying it for another full delay period on de-energization. No power
is required during the timing period.
sequential delays on pull-in and drop-out in one unit. With the addition of
auxiliary switches the basic models provide two-step timing, pulse actuation
for interlock circuits, or added circuit capacity.
Dimensions are shown for
reference purposes only.
NOTE: Seismic & radiation tested E7000 models are available.
markings visible from all angles makes the timer easy to set timers.
hermetically-sealed, NEMA 1.
flexibility.
individual modules, with switches field-replaceable.
There are three main components of Series 7000 Timing Relays:
Calibrated Timing Head uses no needle valve, recirculates air under
Precision-Wound Potted Coil module supplies the initial motive force
Snap-Action Switch Assembly - custom-designed over-center
Each of these subassemblies forms a self-contained module which is
The squared design with front terminals and rear mounting permits the
Two basic operating types are available.
In "Off-Delay" models the switch transfers the load immediately upon
In addition to these basic operating types, "Double-Head" models offer
Consult factory for detailed information.
explosion proof, dust tight, watertight,
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Issued 3-03 (PDF Rev. 10-07)
Catalog 1308242
7000
Industrial Electropneumatic
Timing Relay
Note:7032 types and certain models with accessories are not agency approved.
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent
approvals files of the agencies/laboratories and review them to confirm the
product meets the requirements for a given application.
Consult factory for ordering information.
On-delay model 7012 (delay on pickup)
Off-delay model 7022 (delay on dropout)
be added to either on-delay or off-delay types. They switch additional circuits,
provide two-step timing action, or furnish electrical interlock for sustained coil
energization from a momentary impulse, depending on the type selected and
its adjustment. Because of their simple attachment and adjustment features,
they can be installed at the factory or in the field, by any competent mechanic.
All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480
VAC. A maximum of one Code T or two Code L auxiliary switches may be
added to each relay. The L or LL switch is available with on-delay relays only.
The T switch is available with both the on-delay and off-delay relays.
Auxiliary Switch Options for On-Delay
Instant Transfer (Auxiliary Switch Code L,
maximum of 2 per relay.)
1. Energizing coil begins time delay and transfers auxiliary switch.
2. Main switch transfers after total preset delay.
3. De-energizing coil resets both switches instantly.
Auxiliary switch is nonadjustable.
Two-Step Timing (Auxiliary Switch Code T,
maximum of 1 per relay.)
Specifications and availability
subject to change.
To increase the versatility of the basic timer models, auxiliary switches may
File E15631
series
File LR29186
Applying continuous voltage to the coil
(L1-L2) starts a time delay lasting for
the preset time. During this period the
normally closed contacts (3-5 and 4-6)
remain closed. At the end of the delay
period the normally closed contacts
break and the normally open contacts
(1-5 and 2-6) make. The contacts re-
main in this transferred position until
the coil is deenergized, at which time
the switch instantaneously returns to
its original position.
or after the delay period, will recycle
the unit within 50 msec.
It will then provide a full delay period
upon re-energization, regardless of
how often the coil voltage is interrupt-
ed before the unit has been permitted
to "time-out" to its full delay setting.
Applying voltage to the coil (for at
least 50 msec) will instantaneously
transfer the switch, breaking the nor-
mally closed contacts (1-5 and 2-6),
and making the normally open
contacts (3-5 and 4-6). Contacts
remain in this transferred position as
long as the coil is energized. The
time delay begins immediately upon
de-energization. At the end of the de-
lay period the switch returns to its
normal position.
delay period will immediately return
the timing mechanism to a point
where it will provide a full delay
period upon subsequent de-
energization. The switch remains in
the transferred position.
De-energizing the coil, either during
Re-energizing the coil during the
AGASTAT

Related parts for 7014AB

7014AB Summary of contents

Page 1

... The T switch is available with both the on-delay and off-delay relays. Auxiliary Switch Options for On-Delay Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) 1. Energizing coil begins time delay and transfers auxiliary switch. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. Auxiliary switch is nonadjustable. ...

Page 2

... Auxiliary Switch Options for On-Delay Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) 1. Energizing coil begins time delay and transfers auxiliary switch. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. ...

Page 3

... For delays greater than 200 seconds: 7012*, 7022, 7014*, 7024: +10% 7032: * The first time delay afforded by Model 7012 with min.) and min.) time ranges or Model 7014 with H time range will be approx. 15% longer than subsequent delays due to coil temperature rise. Reset Time: 50 msec. (except model 7032) Relay Release Time: 50 msec ...

Page 4

Outline Dimensions (Dimensions in inches). Models 7012, 7022 Panel mount Option "X" Dimensions are shown for Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 10-07) Models 7014, 7024 Surge/Transient Protection ...

Page 5

Ordering Information 1. Basic Series 7000 series electropneumatic timing relay 2. Operation On-delay 3 = On-delay, off-delay (double head Off-delay 3. Contact Arrangement 2PDT (2 form C) **4 = 4PDT (4 form ...

Related keywords