SU2200R3X167 American Power Conversion (APC), SU2200R3X167 Datasheet - Page 2

no-image

SU2200R3X167

Manufacturer Part Number
SU2200R3X167
Description
UPS; 2200 VA; 1600 W; 120/230; 120 V; Sealed Lead-Acid; 0 to degC; Rack
Manufacturer
American Power Conversion (APC)
Type
Networkr
Datasheet

Specifications of SU2200R3X167

Battery Type
Sealed Lead-Acid
Brand/series
SU Series
Capacity
2200 VA
Color
Beige
Communication
DB9, RS232, SmartSlot
Dimensions
132mmH×483mmW×635mmD
Frequency, Output
47 to 53 Hz for 50 Hz (Nom.), 57 to 63 Hz for 60 Hz (Nom.)
Input Type
NEMA 5-20P
Interface
DB-9 RS-232, Smartslot
Length, Cord
1.83 m
Mounting Type
Rack/Tower
Output Type
(8) NEMA 5-15R
Power, Rating
1600 W
Standards
UL Listed and CSA Certified
Temperature, Operating
0 to +40 °C
Time, Backup
6.8 min.
Voltage, Nominal
120⁄230
Voltage, Output
120 V
Voltage, Supply
1600/2200 W/VA
Weight
46.82 kg
Smart-UPS Features & Benefits
Availability
Manageability
Serviceability
Boost and Trim
Automatic Voltage
Regulation (AVR)
Intelligent Battery
Management
Power conditioning
Temperature-
compensated battery
charging
Automatic restart of
loads after UPS
shutdown
Automatic self-test
Cold-start capable
Disconnected battery
notification
Generator Compatible Ensures clean, uninterrupted power to protected equipment when generator
Network manageable Provides remote management of the UPS over the network.
SmartSlot
Audible Alarms
LED status indicators Quickly understand unit and power status with visual indicators.
Serial Connectivity
USB Connectivity
Disconnected battery
notification
InfraStruXure
Manager Compatible
User-replaceable
batteries
Hot-swappable
batteries
Predictive failure
notification
Resettable circuit
Gives higher application availability by correcting low and high voltage
conditions without using the battery.
Maximizes battery performance, life, and reliability through intelligent,
precision charging.
Protects connected loads from surges, spikes, lightning, and other power
disturbances.
Prolongs battery life by regulating the charge voltage according to battery
temperature.
Automatically starts up the connected equipment upon the return of utility
power.
Periodic battery self-test ensures early detection of a battery that needs to be
replaced.
Provides temporary battery power when the utility power is out.
Warns when a battery is not available to provide backup power.
power is used.
Customize UPS capabilities with management cards.
Actively let you know if the unit is on battery, if the battery is low or if there
is an overload condition.
Provides management of the UPS via a serial port.
Provides management of the UPS via a USB port (not available on all
models).
Warns when a battery is not available to provide backup power.
Enables centralized management via the APC InfraStruXure® Manager.
Increases availability by allowing a trained user to perform upgrades and
replacements of the batteries reducing Mean Time to Repair (MTTR)
Ensures clean, uninterrupted power to protected equipment while batteries
are being replaced
Provides early-warning fault analysis ensuring proactive component
replacement.
Enables a quick recovery from overload events.