F48-250 Triad Magnetics, F48-250 Datasheet

Transformer; 12VA; Sec:Ser 0.25A, Par 0.5A; Pri:115/230V; Sec:Ser 48VCT, Par 24V; PC

F48-250

Manufacturer Part Number
F48-250
Description
Transformer; 12VA; Sec:Ser 0.25A, Par 0.5A; Pri:115/230V; Sec:Ser 48VCT, Par 24V; PC
Manufacturer
Triad Magnetics
Type
Powerr
Datasheets

Specifications of F48-250

Brand/series
Split Pack®/F Series
Configuration
Bobbin
Current, Secondary
0.5/0.25 A
Dielectric Strength
2500 Vrms
Dimensions
1-7/8"L×1-9/16"W×1-7/16"H
Frequency
50/60 Hz
Mounting Type
PCB
Number Of Outlets
2
Phase
1
Power, Rating
12 VA
Standards
UL, cULus
Temperature, Operating
+25 °C
Termination
Thru-Hole
Voltage, Primary
115/230 VAC
Voltage, Secondary
24/48 VAC
Weight
0.7 lbs.
Power Rating
12 VA
Primary Voltage Rating
115 V
Secondary Voltage Rating
24 V / 48 V
Mounting Style
SMD/SMT
Product
Power Transformers
Height
1.437 in
Length
1.875 in
Termination Style
Solder
Width
1.562 in
Lead Free Status / Rohs Status
RoHS Compliant part
F48-250
Description:
The F48-250 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 48.0V with a
center-tap under a 0.25A load with the secondaries wired in series, or 24.0V
under a 0.5A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 12.0VA
2. Primary:
3. Secondary: Series: 48.0V CT@ 0.25A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
This model is also available in Class 3, UL 5085-3 (1585) version as
Dimensions:
Weight: 0.70 lbs
Schematic:
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet the
requirements of 2002/95/EC, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectably.
1.437
50/60Hz
H
115V
1.562
W
4
1
115V
Parallel: 24.0V @ 0.5A
1.875
L
0.300
A
0.400
5
6
7
8
B
1.410
C
0.041
D
Units in inches.
P
P C M O U N T : SPLIT PACK
O W E R
0.020
E
F48-250-C2
0.234
F
T
R A N S F O R M E R
5
1
1
Board Layout
E
A
0.06" DIAMETER
D
W
B
L
HOLE
A
4
8
4
C
F
H

Related parts for F48-250

F48-250 Summary of contents

Page 1

... F48-250 Description: The F48-250 is a single primary and dual secondary, split bobbin design which operates with an input of 115V. The output voltage will be either 48.0V with a center-tap under a 0.25A load with the secondaries wired in series, or 24.0V under a 0.5A load with the secondaries wired in parallel. The split bobbin design eliminates the need for costly electrostatic shielding ...

Page 2

... FS48-125 F56-110 FS56-110 F120-050 FS120-05 F10-1200 FS10-1200 F12-1000 FS12-1000 F16-800 FS16-800 F20-600 FS20-600 F24-500 FS24-500 D 12.0 F28-420 FS28-420 F36-350 FS36-350 F48-250 FS48-250 F56-220 FS56-220 F120-100 FS120-100 F10-2000 FS10-2000 F12-1600 FS12-1600 F16-1250 FS16-1250 F20-1000 FS20-1000 F24-800 FS24-800 E 20.0 F28-700 FS28-700 F36-550 FS36-550 ...

Page 3

... Pin 8 Pin VA F10-3600 FS10-3600 F12-2850 FS12-2850 F16-2250 FS16-2250 F20-1800 FS20-1800 F24-1500 FS24-1500 A 36.0 F28-1300 FS28-1300 F36-1000 FS36-1000 F48-750 FS48-750 F56-650 FS56-650 F120-300 FS120-300 * 36 VA size has 4 mtg. holes ⁄ ⁄ centers Center Tap Hi-pot tested at 2,500 VRMS terminal pin spacing for accurate placement. ...

Related keywords