24D1-100SST2 AMPERITE, 24D1-100SST2 Datasheet

no-image

24D1-100SST2

Manufacturer Part Number
24D1-100SST2
Description
Relay; SSR; Timing; Single Shot; SPST-NO; Cur-Rtg 2A; Ctrl-V 24DC; 1-100 sec; ST2 Series
Manufacturer
AMPERITE
Datasheet

Specifications of 24D1-100SST2

Brand/series
ST2 Series
Contact Form
SPST-NO
Current, Rating
2 A
Function
Timing
Relay Type
Solid State
Repeatability
2 %
Standards
UL, CSA
Termination
Quick Connect
Timer Type
Single Shot
Timing Range
1 to 100 sec.
Voltage, Control
24 VDC
Timing Mode:
Upon application of power the load is energized and the time delay cycle is initiated. At
the end of the delay time the load is de-energized. Reset is accomplished by removing
input power.
Timing Diagram:
Contact Information:
Solid state switching device 1 form A; normally open series connection. Continuous
current rating 2 amperes. Maximum inrush 20 amperes. Voltage drop 2.5 volts RMS or
less @ 2 amperes. (For 10 ampere load current rating consult factory)
Timing Specifications:
Timing: Factory fixed, or .1 seconds to 100 hours in any of the ranges below. Timing is
set by user supplied resistor or potentiometer. Custom timing available.
Interval (One-Shot)
ST2 Series Solid
Timer
State
Solving your relay requirements since 1922
… 100% solid state circuitry - no
moving parts
… CMOS digital timing circuitry
… Fixed or field adjustable delays
from milliseconds to hours
… 2 amperes continuous load current
(10 amperes available, consult factory)
… UL File # Pending
… CSA File #Pending

Related parts for 24D1-100SST2

24D1-100SST2 Summary of contents

Page 1

... ST2 Series Solid State Interval (One-Shot) Timer Timing Mode: Upon application of power the load is energized and the time delay cycle is initiated. At the end of the delay time the load is de-energized. Reset is accomplished by removing input power. Timing Diagram: Contact Information: Solid state switching device 1 form A; normally open series connection. Continuous current rating 2 amperes ...

Page 2

Solving your relay requirements since 1922 Timing ranges seconds . seconds 1 to 100 seconds 10 to 1000 seconds . minutes Timing tolerance: fixed units +/- 10% Timing repeatability: 2% Timing cycle interrupt ...

Page 3

... Solving your relay requirements since 1922 External Resistor Selection: Wiring Diagrams: Mechanical Information: Enclosure 3/4 inch black plastic, epoxy sealed. Center hole mounting. Three or five 1/4 inch quick connect male terminals Ordering Information: Definition of a part number for the Amperite ST2 Series Time Delay Relay: Example: ...

Page 4

... C is the minimum timing and D is the maximum timing. Standard timing span is 100:1. For fixed timing units specify a single number. E: Denotes unit of time delay: S=seconds; M=minutes; H=hours. F: Denotes Amperite ST2 Series solid state, normally open time delay. Solving Your Relay Requirements Since 1922 ...

Related keywords