AFPX-COM4 Panasonic Electric Works, AFPX-COM4 Datasheet

no-image

AFPX-COM4

Manufacturer Part Number
AFPX-COM4
Description
PLC; COMMUNICATION CASSETTE; RS232; RS485/422; 115K MAX BAUDRATE
Manufacturer
Panasonic Electric Works
Type
Communicationsr
Datasheet

Specifications of AFPX-COM4

Brand/series
AFPX
Primary Type
Option
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
Modular Controllers
Panasonic... the new name for
4-Axis Integrated Control
Introducing a New Transistor Output Model
Pulse Output
FP-X Programmable Controller
ARCT1B273E ’06.8
14-point type
Matsushita Electric Works, Ltd.
30-point type
Programmable Controller
2-Axis Linear
Interpolation
Simultaneously
in 2 Pairs!
60-point type
New

Related parts for AFPX-COM4

AFPX-COM4 Summary of contents

Page 1

Introducing a New Transistor Output Model 4-Axis Integrated Control Panasonic... the new name for Pulse Output 14-point type 30-point type FP-X Programmable Controller ARCT1B273E ’06.8 Matsushita Electric Works, Ltd. Programmable Controller 2-Axis Linear Interpolation Simultaneously in 2 Pairs! 60-point type ...

Page 2

... Program protection with an 8-digit password and a function prohibiting uploads 3 USB-port Equipped* Easy direct connection with a PC via a commercial USB cable (AB type) *3: Not provided with C14. 2 AFPX-C60 (Add-on cassette attached) New Functions Easy-to-use Temperature Control Command (F356 EZPID) MEWTOCOL Master Function Ethernet Add-on Unit Trace Function ...

Page 3

... With such applications in mind, FP compact general-purpose PLC suited for small-scale equipment controls with its 4-axis pulse output built into the compact body, enabling multi-axis control in a very small space at a fraction of the equipment cost. AFPX-C30 (Add-on cassette attached) (C14 comes with 3 axes) AFPX-C14 (Add-on cassette attached) 3 ...

Page 4

... Communication cassette AFPX-COM1 Communication cassette (RS232C 1 ch.) AFPX-COM2 Communication cassette (RS232C 2 ch.) Communication cassette AFPX-COM3 (RS485/422 selectable 1 ch.) Communication cassette AFPX-COM4 (RS485 RS232C 1 ch.) AFPX-COM5 Communication cassette (Avail. April 2007) (Ethernet RS232C 1 ch.) Application cassette AFPX-IN8 Input cassette ( input ch.) Output cassette AFPX-TR8 (NPN transistor 0 ...

Page 5

... Only the communication cassette can be upper. Control Unit (Model: Relay output type AFPX-C30R) Expansion Unit (Model: Relay output type AFPX-E16R) Add-on Cassette (Model: Analog input cassette AFPX-AD2) Input/output terminals or communication signal terminals Expansion cassette interface cover Connector for add-on cassette Connector for ...

Page 6

... G The relay output type can control two axes by using the expansion cassettes Pulse output up to 2-axis 80kHz is possible by loading two pulse I/O cassettes (AFPX-PLS). Also capable of performing 2-axis linear interpolation. Pulse I/O cassette doesn’t First Second ...

Page 7

... Invisible changes become visible! I The communication cassette (Ethernet Type) will be April 2007. Using this option, you can monitor the data in FP-X on the PCWAY through the existing Ethernet, or remotely upload/download a program. AFPX-COM5 Ethernet RS232C (Even when all output ports are ON) Interface Ethernet ...

Page 8

... Measured value Target value Output value Modbus-RTU Easy unification of data management FP-X T/C T/C T/C T/C For connecting a thermocouple, please use an FP0 thermocouple unit via an adapter (AFPX-EFP0). Multi-step control by changing the target value Target value Time Y0 DT100 Output address Multiple temperature controllers T/C ...

Page 9

High capacity/High speed The high-level basic performance provides sufficient room for future equipment expansion as well as a rich variation. I Abundant program capacity - The program capacity of 32 ksteps, exceeding the capacity of most compact PLCs, can flexibly ...

Page 10

... RS232C AFPX-COM2 RS485/RS422 selectable AFPX-COM3 RS485 + RS232C AFPX-COM4 Ethernet 1ch + RS232C 1 ch (Available April 2007) AFPX-COM5 *1: Each of RS485 and RS422 is an insulated type. I When further expansion or functions are required, use the existing All control units can be expanded FP0 expansion units via an adapter. ...

Page 11

... GThe transfer rate of 115.2 kbps, the highest rate for a compact model. GA transfer distance of 1200 m, the longest distance for a compact model. GFP-X and FPΣ allow a change of the station number by programming (SYS instruction). FP-X requires a communication cassette (AFPX-COM3 or AFPX-COM4) FP2/2SH requires a multi-communication unit (AFP2465, AFP2805) FPΣ requires a communication cassette (AFPG803, AFPG806) ...

Page 12

... I No need for program backup − easy maintenance GThe programs and comments are stored in flash ROM, requiring no backup batteries. GA backup battery is provided for data and real-time clock (AFPX-BATT) One battery for C14, two for C30 and three for C60 can be attached. A two- battery installation can operate for a long time (10 years or more) without maintenance ...

Page 13

Programming Control FPWIN GR for Windows The ladder programming software for FP series − − highly operational software tool for maximizing convenience in the field. I Features 1. Easy field operations not requiring the use of a mouse for data ...

Page 14

Programming Control FPWIN Pro (IEC61131-3 compliant Windows version software) Compliant with international standard IEC61131-3 Programming software approved by PLC Open I Programming in the most suitable language GProgramming in the language most suited to the process Easy-to-understand, efficient programs can ...

Page 15

... AFPX-C14PD AFPX-C14P AFPX-C30TD AFPX-C30T AFPX-C30PD AFPX-C30P AFPX-C60TD AFPX-C60T AFPX-C60PD AFPX-C60P Part number AFPX-E16R AFPX-E30R AFPX-E16T AFPX-E16P AFPX-E30TD AFPX-E30T AFPX-E30PD AFPX-E30P AFPX-EFP0 Part number AFPX-COM1 AFPX-COM2 AFPX-COM3 AFPX-COM4 AFPX-COM5 AFPX-IN8 AFPX-TR8 AFPX-TR6P AFPX-AD2 AFPX-PLS AFPX-MRTC Part number AFPX-BATT AFPX-EC08 AFPX-EC30 AFPX-EC80 AFPX-TAN1 15 ...

Page 16

Part Number List FP0 Expansion Units Product name Number of I/O points 8 Input: 8 Input Output: 4 FP0 E8 Expansion Unit Output Output Input Input Output: 8 FP0 E16 ...

Page 17

... AFPX-C30❍❍ less AFPX-C60❍❍ less AFPX-E16❍❍ less AFPX-E30❍❍ less AFPX-EFP0 0. less AFPX-COM1 less AFPX-COM2 less AFPX-COM3 less AFPX-COM4 less AFPX-COM5 less AFPX-AD2 less AFPX-IN8 less AFPX-TR8 less AFPX-TR6P less AFPX-PLS less AFPX-MRTC less *3 Power consumption by the DC power supply connected to the expansion FP0 adapter ...

Page 18

... Pulse I/O cassette (AFPX-PLS) for relay output type: single-phase 2 ch (80 kHz x 2 ch) Built-in (Transistor output): 100 kHz kHz Pulse I/O cassette (AFPX-PLS) for relay output type: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz Relay output type: Total 14 points (including the high-speed counter) Transistor output type: Total 8 points (including the high-speed counter) 0 ...

Page 19

Specifications 4. Input Specifications (Control unit, expansion unit) Item Insulation method Rated input voltage Operating voltage range Approx. 4.7 mA (Control unit X0 to X7) Rated input current Approx 4.3 mA (Control unit X8 and after, expansion unit) Input points ...

Page 20

... Tool port connector 24V Cassette attachment area 1 Application cassette Communication cassette Battery Expansion unit connector GAFPX-C30 ∗ ∗ (The same dimensions apply to the expansion I/O unit AFPX-E30∗ ∗) Status display LED COM L N COM RUN PROG. ERR. Input/output display LED ...