K8AB-VS1 24VAC/DC Omron Automation, K8AB-VS1 24VAC/DC Datasheet

no-image

K8AB-VS1 24VAC/DC

Manufacturer Part Number
K8AB-VS1 24VAC/DC
Description
Relay; Voltage Monitor; 60-150m V 1-ph voltage monitor
Manufacturer
Omron Automation
Datasheet
Ideal for voltage monitoring for industrial
facilities and equipment.
• Monitor for overvoltages or undervoltages.
• Manual resetting and automatically resetting supported by one
• One SPDT output relay, 6 A at 250 VAC (resistive load).
• Output relay can be switched between normally open and
• Process control signal (0 to 10 V) and current splitter input
• Output status can be monitored using LED indicator.
• Input frequency of 40 to 500 Hz supported.
• Inputs are isolated from the power supply.
Model Number Structure
■ Model Number Legend
1. Basic Model
2. Functions
3. Measuring Current
4. Supply Voltage
K8AB-@@
Relay.
normally closed.
supported.
Single-phase Voltage Relay
K8AB-VS
K8AB:
VS:
1:
2:
3:
24 VAC/DC:
100-115 VAC: 100 to 115 VAC
200-230 VAC: 200 to 230 VAC
1
Refer to Safety Precautions for the K8AB
Series. Refer to page 9 for the Q&A section.
2 3
Measuring and Monitoring Relays
Single-phase Voltage Relay (One-sided operation)
6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC
1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC
20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC
24 VAC/DC
4
CSM_K8AB-VS_DS_E_3_1
1

Related parts for K8AB-VS1 24VAC/DC

K8AB-VS1 24VAC/DC Summary of contents

Page 1

... Output status can be monitored using LED indicator. • Input frequency 500 Hz supported. • Inputs are isolated from the power supply. Refer to Safety Precautions for the K8AB Series. Refer to page 9 for the Q&A section. Model Number Structure ■ Model Number Legend ...

Page 2

... V AC/ 200 V AC/DC 300 V AC/DC 600 V AC/DC ■ Shunts (Order Separately) A shunt is a resistor to convert a DC current into a DC voltage. Use the shunt in combination with K8AB-VS to detect undercurrent and overcurrent in DC circuits. Model Rated current SDV-SH5 5 A SDV-SH7.5 7 ...

Page 3

... K8AB-VS1 AC/ 100 mV AC/ 300 mV AC/DC K8AB-VS2 AC/ AC/ 150 V AC/DC K8AB-VS3 200 V AC/ 300 V AC/ 600 V AC/DC 100% operation at set value 5% to 50% of operating value Manual reset/automatic reset (switchable) Note: Manual reset: Turn OFF power supply for longer. ...

Page 4

... V power supply terminal common/normal mode Square-wave noise of ±1 µs/100 ns pulse width with 1-ns rise time Frequency Hz, 0.35-mm single amplitude, acceleration 50 m/s 10 sweeps of 5 min each and Z directions 2 100 m times each in 6 directions along three axes (up/down, left/right, forward/backward) Terminal section: Finger protection K8AB- ...

Page 5

... Note: The power ON lock prevents unnecessary alarms from being generated during the instable period when the power is first turned on. There is no relay output during timer operation. Single-phase power A1 Power supply voltage A2 V1 Voltage input Signal output 12 Load Note: There is no polarity when a DC current input is used. K8AB-VS COM 11 Relay signal output 5 ...

Page 6

... Al 1,5-8BK (for AWG16) • Al 1-8RD (for AWG18) • Al 0,75-8GY (for AWG18) 2. Tightening torque Recommended: 0.49 N·m Maximum: 0.54 N·m K8AB-VS Meaning Lit when power is being supplied. Lit when relay is operating Lit when there is an overvoltage or undervoltage. The indicator flashes to indicate the error ...

Page 7

... Resetting Automatic reset method Manual reset Relay drive Normally closed method Normally open Operating Undervoltage mode Overvoltage Note: All pins are set to OFF at the factory. K8AB-VS Single-phase power A1 Power supply voltage A2 V1 Voltage input COM Signal output Relay 12 ...

Page 8

... Use this as a guide to set the voltage. The maximum measuring voltage will differ depending on the model and the input terminal. Example: K8AB-VS3 Using Input Terminal V3-COM The maximum measuring voltage will be 600 VAC/VDC and the setting range will 600 V. 2. Hysteresis Hysteresis is set using the hysteresis knob (HYS ...

Page 9

... Undervoltage Gradually decrease the input from 120% of the setting and check the operation using the same method as for overvoltage. Example: Overvoltage Operating Mode and an Operating Time Note: K8AB-VS@ output relays are normally operative. Set value Input voltage Flashing Alarm indicator 5 s ...