LFA150F-12 Cosel U.S.A. Inc., LFA150F-12 Datasheet - Page 17

no-image

LFA150F-12

Manufacturer Part Number
LFA150F-12
Description
POWER SUPPLY; INTERNAL; SINGLE OUTPUT; UNIVERSAL INPUT; SWITCHING; 150W; 12VDC;
Manufacturer
Cosel U.S.A. Inc.
Type
Industrialr
Datasheet

Specifications of LFA150F-12

Brand/series
LFA Series
Configuration
Open Frame
Mounting Type
Desktop
Number Of Outputs
1
Power, Output
150.0 W
Primary Type
AC-DC
Voltage, Input
85-264 VAC
Voltage, Output
12.0 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LFA150F-12
Manufacturer:
COSEL
Quantity:
323
LFA
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
SPECIFICATIONS
E-20
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*3
Specifi cation is changeed at option, refer to Instruction Manual.
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
Drift is the change in DC output for an eight hour period after a
half-hour warm-up at 25C, with the input voltage held constant
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT . RC
INPUT-FG
OUTPUT . RC-FG
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
*5
Convection
Forced air
LFA300F
Rugged PCB type
*5
ACIN 100V 2.7typ (Io=100%) 4.1typ (Io=100%)
ACIN 200V 1.4typ (Io=100%) 2.0typ (Io=100%)
ACIN 100V 74.0typ
ACIN 200V 76.0typ
ACIN 100V 0.98typ
ACIN 200V 0.92typ
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
Convection 40
Forced air 60
0 to +40C
-10 - 0C
0 to +40C
-10 - 0C
-10 to +40C 60max
0 to +40C 50max
*5
*3
*2
*2
*6
*6
*6
*4
*7
*7
*2
*2
LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY
198
3.3V 40A
3.3V 60A
LFA300F-3R3-TY LFA300F-5-TY
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
50 / 60 (47 - 63)
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
20max
40max
80max
140max
120max
160max
20max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
2.85 to 3.63 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80
3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92
4.00 to 5.25
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
10 - 55Hz, 19.6m/ s
196.1m/s
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
95X52.5X222mm (WXHXD) (without terminal block) / 810g max
Convection / Forced air (Refer to DERATING CURVE)
*4
*5
*6
*7
2
(20G), 11ms, once each X, Y and Z axis
300
5V 40A
5V 60A
79.0typ
82.5typ
0.99typ
0.95typ
5
40
60
20max
40max
80max
140max
120max
160max
50max
60max
20max
5.75 to 7.00
at the rated input/output.
Derating is required.
( ) means peak current. There is a possibility that an internal
device is damaged when the specifi cation is exceeded. Please
contact us about the detail..
Applicable when remote control (optional) is added.
Please contact us about dynamic load and input response.
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
324
12V 17A
12V 27A
LFA300F-12-TY
80.0typ
83.0typ
12
17
27
48max
100max
120max
160max
150max
180max
120max
150max
48max
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20
330
15V 14A
15V 22A
LFA300F-15-TY
81.0typ
84.0typ
15
14
22
60max
120max
120max
160max
150max
180max
150max
180max
60max
1
Ordering information
LF
336
24V 12.5A 24V 12.5 (19)A 30V 10A
24V 14A
LFA300F-24-TY
84.0typ
87.0typ
24
12.5
14
96max
150max
120max
160max
150max
180max
240max
290max
96max
2
A
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
Recommended Noize Filter
NAC-06-472
*4
*
*
*
*
336 (456)
24V 14 (19)A 30V 11A
LFA300F-24-HTY LFA300F-30-TY
84.0typ
87.0typ
24
12.5 (Peak19) 10
14 (Peak19) 11
96max
150max
240max
320max
300max
360max
240max
290max
96max
3
300
To meet the specifi cations. Do not operate over-loaded
condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of
pulse load.
330
84.0typ
87.0typ
30
144max
240max
150max
200max
250max
300max
360max
450max
144max
4
F
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Please refer to Instruction manual 5.
SNF: with Chassis & cover & fan
T1: Holizontal terminal block
C : with Coating
G : Low leakage current
H : with the function to be acceptable
J : EP (Tyco Electronics) connector type
J1 : VH (J.S.T.) connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
302.4
36V 8.4A
36V 9.4A
LFA300F-36-TY
84.0typ
87.0typ
36
8.4
9.4
144max
240max
150max
200max
250max
300max
360max
450max
144max
5
(under application)
to output peak current
- □
*1
302.4
48V 6.3A
48V 7A
LFA300F-48-TY
84.0typ
87.0typ
48
6.3
7
192max
240max
150max
200max
250max
300max
480max
600max
192max
6
- □

Related parts for LFA150F-12