LFA150F-5-Y

Manufacturer Part NumberLFA150F-5-Y
DescriptionPOWER SUPPLY; INTERNAL; SINGLE OUTPUT; UNIVERSAL INPUT; SWITCHING; 150W; 5VDC; 3
ManufacturerCosel U.S.A. Inc.
TypeIndustrial
LFA150F-5-Y datasheet
 

Specifications of LFA150F-5-Y

Brand/seriesLFA SeriesConfigurationOpen Frame
Mounting TypeDesktopNumber Of Outputs1
Power, Output150.0 WPrimary TypeAC-DC
Voltage, Input85-264 VACVoltage, Output5.0 VDC
Lead Free Status / Rohs StatusRoHS Compliant part  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
Page 15/18

Download datasheet (593Kb)Embed
PrevNext
Rugged PCB type
LFA240F
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
*5
*5
DC OUTPUT
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V 3.3typ (Io=100%)
CURRENT[A]
ACIN 200V 1.7typ (Io=100%)
FREQUENCY[Hz]
LFA
ACIN 100V 84.0typ
EFFICIENCY[%]
INPUT
ACIN 200V 87.0typ
ACIN 100V 0.99typ
POWER FACTOR (Io=100%)
ACIN 200V 0.95typ
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
INRUSH CURRENT[A]
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*5
*7
LINE REGULATION[mV]
*7
LOAD REGULATION[mV]
0 to +40C
*2
RIPPLE[mVp-p]
-10 - 0C
*2
0 to +40C
*2
RIPPLE NOISE[mVp-p]
*2
OUTPUT
-10 - 0C
0 to +40C 240max
TEMPERATURE REGULATION[mV]
-10 to +40C 290max
DRIFT[mV]
*3
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION
PROTECTION
CIRCUIT AND
OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT . RC
*6
INPUT-FG
ISOLATION
OUTPUT . RC-FG
*6
OUTPUT-RC
*6
OPERATING TEMP.,HUMID.AND ALTITUDE
*4
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
Specifi cation is changeed at option, refer to Instruction Manual.
*2
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*3
Drift is the change in DC output for an eight hour period after a
half-hour warm-up at 25C, with the input voltage held constant
E-18
Ordering information
LF
1
LFA240F-24
LFA240F-24-H
240
240 (300)
24V 10A
24V 10 (12.5)A
LFA240F-24
LFA240F-24-H
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
50 / 60 (47 - 63)
84.0typ
87.0typ
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
24
10
10 (Peak12.5)
96max
96max
150max
150max
120max
240max
160max
320max
150max
300max
180max
360max
240max
290max
96max
96max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
Fixed ( Y option is available for adjusting output voltage)
23.00 to 25.00
23.00 to 25.00
27.60 to 33.60
27.60 to 33.60
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
10 - 55Hz, 19.6m/ s
(2G), 3minutes period, 60minutes each along X, Y and Z axis
2
196.1m/s
(20G), 11ms, once each X, Y and Z axis
2
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
84X46.5X180mm (WXHXD) / 550g max (without chassis and cover)
Convection
at the rated input/output.
*4
Derating is required.
*5
( ) means peak current. There is a possibility that an internal
device is damaged when the specifi cation is exceeded. Please
contact us about the detail.
*6
Applicable when remote control (optional) is added.
*7
Please contact us about dynamic load and input response.
- □
A
240
F
2
3
4
5
1Series name
Recommended Noize Filter
2Single output
NAC-06-472
3Output wattage
4Universal input
5Output voltage
6Optional
*1
C : with Coating
G : Low leakage current
H : with the function to be acceptable
High voltage pulse noise type : NAP series
to output peak current (only 24V)
Low leakage current type : NAM series
J1: VH(J.S.T.)connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
T : Vertical terminal block
Y: with Potentiometer
Please refer to Instruction
manual 5.
LFA240F-36
LFA240F-48
241.2
240
36V 6.7A
48V 5A
LFA240F-36
LFA240F-48
*4
84.0typ
84.0typ
87.0typ
87.0typ
36
48
6.7
5
144max
192max
240max
240max
150max
150max
200max
200max
250max
250max
300max
300max
360max
480max
450max
600max
144max
192max
34.50 to 37.50
46.00 to 50.00
41.40 to 50.40
55.20 to 67.20
(under application)
*
To meet the specifi cations. Do not operate over-loaded
condition.
*
Parallel operation is not possible.
*
Derating is required when operated with chassis and cover.
*
Sound noise may be generated by power supply in case of
pulse load.
- □
6