S48A50-22 TELEDYNE, S48A50-22 Datasheet

no-image

S48A50-22

Manufacturer Part Number
S48A50-22
Description
Relay; SSR; Control; Cur-Rtg 50A; Ctrl-V 24AC; Vol-Rtg 520V; Screw; UL; S Series
Manufacturer
TELEDYNE
Datasheet

Specifications of S48A50-22

Application
Heating control, motor control, uninterruptible power supplies, light dimmers, industrial and process control, on⁄off controls of AC equipment
Brand/series
S Series
Current, Leakage, Off-state
3 mA
Current, Rating
50 A
Current, Surge
1000 A
Dimensions
2.29 in. L x 1.75 in. W x 1.06 in. H
Function
General Purpose
Relay Type
Solid State
Standards
UL
Temperature, Ambient, Maximum
100 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Screw
Voltage, Control
24 VAC
Voltage, Rating
520 V
Part Numbers
Package &
Part Number Example: S48A25-22
NOTES
1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac; 60 = 600 Vac
2) Switch Type: R = Random turn-on; D = Zero-cross turn-on;
3) Feature: -22 = 24 Vac control. Available on A type 240 Vac, 25 and
Chip Type
TOLERANCES: ±.01 (0.3)
125A model uses larger M5 output screw terminals
1.06 (27)
1.02 (25.8)
.9 (22.8)
S
S
S
.77 (19.6)
(±.02)
40A models and A type 480 Vac, 25, 50, 125A models
(±0.5)
MECHANICAL SPECIFICATION
A = AC control, Zero-cross turn-on
Figure 1 — S relays, 12–95 A;
Voltage
dimensions in inches (mm)
Line
24
48
60
Ø.19 (Ø4.7)
1
Switch
Type
R
D
A
R
D
A
D
WEIGHT: 3.18 oz. (90g)
1~
4-
2
1.75 (44.5)
1 (25.4)
1.1 (28)
Current
Output
125
125
12
25
40
25
50
75
95
50
75
95
2~
3+
Feature
-22
-22
M 4
M 3
3
FEATURES/BENEFITS
• Industry standard package
• Internal snubber (except S60 models)
• Designed for all types of loads
• AC or DC control available
• Excellent thermal performance
• Tight zero-cross window for low EMI
• High immunity to surges
DESCRIPTION
The Series S single-phase relays are designed for all
types of loads. The design incorporates an SCR or
triac output. The relays utilize optical isolation to protect
the control from load transients. All contain an internal
snubber for output protection. High-current models are
excellent for motor and phase angle control.
APPLICATIONS
• Heating control
• Motor control
• Uninterruptible power supplies
• Light dimmers
• Industrial and process control
• On/Off controls of AC equipment
APPROVALS
S24 and S48 models are UL recognized.
UL File Number: E128555.
* 1-2 can be changed
* SSR must be mounted on a heat sink
Control
+
-
TYPICAL APPLICATION
Figure 2 — S relays
4–
3+
Single Output to 125A 660 Vac
Line Protection
1
2
AC/DC Control
Line Voltage
Series S
LOAD

Related parts for S48A50-22

S48A50-22 Summary of contents

Page 1

Part Numbers Package & Line Switch 1 2 Chip Type Voltage Type Part Number Example: S48A25-22 NOTES 1) Line Voltage (nominal 240 Vac ...

Page 2

... Vdc 15 Vac 2 1 Vac 3 Vac Figure 3c — S24A and S48A relays 1000 Ohms 30,000 Ohms 30 3000 Ohms Figure 3d — Sxxxxx-22 relays Series Control Voltage ( 100 120 140 160 180 200 220 240 Control Voltage ( Control Voltage (V) © 2003 TELEDYNE RELAYS S\032003\Q1 ...

Page 3

OUTPUT (LOAD) SPECIFICATION Input Type Min Operating Range S24 12 S48 24 S60 24 Peak Voltage S24 S48 S60 Load Current Range (Resistive) 12A output current .005 25A output current .005 40A output current .005 50A output current .005 75A ...

Page 4

...

Related keywords