IS43DR16320B-3DBL ISSI, Integrated Silicon Solution Inc, IS43DR16320B-3DBL Datasheet - Page 16

no-image

IS43DR16320B-3DBL

Manufacturer Part Number
IS43DR16320B-3DBL
Description
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
DDR2 SDRAMr
Datasheet

Specifications of IS43DR16320B-3DBL

Organization
32Mx16
Density
512Mb
Address Bus
15b
Access Time (max)
450ps
Maximum Clock Rate
667MHz
Operating Supply Voltage (typ)
1.8V
Package Type
FBGA
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
1.9V
Operating Supply Voltage (min)
1.7V
Supply Current
280mA
Pin Count
84
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS43DR16320B-3DBL
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS43DR16320B-3DBL
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS43DR16320B-3DBLI
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
IS43DR16320B-3DBLI
Manufacturer:
ISSI
Quantity:
24
IS43/46DR86400B, IS43/46DR16320B
AC and DC Logic Input Levels
Single-ended DC Input Logic Level
Single-ended AC Input logic level
AC Input Test Conditions
Notes:
1.
2.
3.
AC Input Test Signal Waveform
Differential Input AC logic level
Notes:
1.
2.
3.
Integrated Silicon Solution, Inc. – www.issi.com –
Rev. E, 01/17/2011
Note: Refer to Overshoot and Undershoot Specification for Vpeak value: maximum peak amplitude allowed for overshoot and undershoot.
Symbol
VREF
VSWING(Max)
SLEW
Input waveform timing is referenced to the input signal crossing through the VIH/IL(AC) level applied to the device under test.
The input signal minimum slew rate is to be maintained over the range from VREF to VIH(AC) min for rising edges and the range from VREF to VIL(AC) max for
falling edges as shown in the below figure.
AC timings are referenced with input waveforms switching from VIL(AC) to VIH(AC) on the positive transitions and VIH(AC) to VIL(AC) on the negative transitions.
VID(AC) specifies the input differential voltage |VTR -VCP | required for switching, where VTR is the true input signal (such as CK, DQS, LDQS or UDQS) and VCP
is the complementary input signal (such as CK#, DQS#, LDQS# or UDQS#). The minimum value is equal to V IH(AC) - V IL(AC).
The typical value of VIX(AC) is expected to be about 0.5 x VDDQ of the transmitting device and VIX(AC) is expected to track variations in VDDQ. VIX(AC) indicates
the voltage at which differential input signals must cross.
Refer to Overshoot and Undershoot Specifications for Vpeak value: maximum peak amplitude allowed for overshoot and undershoot.
VID(AC)
Symbol
VIX(AC)
VIH(AC)
Symbol
VIL(AC)
VIH(DC)
Symbol
VIL(DC)
Input signal maximum peak to peak swing
AC differential crosspoint voltage
AC input logic HIGH
AC input logic LOW
AC differential input voltage
Input signal minimum slew rate
Parameter
Input reference voltage
Parameter
DC input logic HIGH
DC input logic LOW
Condition
Parameter
VSSQ - Vpeak
VREF + 0.250
Min.
DDR2-400, DDR2-533
0.5*VDDQ-0.175
VDDQ + Vpeak
VREF - 0.250
Min.
VREF + 0.125
0.5
Max.
Min.
- 0.3
0.5 x VDDQ
Value
1.0
1.0
VSSQ - Vpeak
VREF + 0.200
0.5*VDDQ+0.175
Min.
VDDQ + 0.6
DDR2-667, DDR2-800
VDDQ + 0.3 V
VREF - 0.125
Max.
Max.
VDDQ + Vpeak
VREF - 0.200
Max.
Units
V/ns
V
V
Units
V
V
Units
V
V
Notes
2, 3
Notes
Units
1
1
1, 3
V
V
2
16

Related parts for IS43DR16320B-3DBL