Switch Function Configuration
N.C.
Current Rating (max)
0.75A
Operating Temp Range
-10C to 55C
Lead Free Status / Rohs Status
Compliant
Characteristics
Note: 1. The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
*3. Do not pass the 1 A, 125 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual
Degree of protection *1
Durability *2
Operating speed
Operating frequency
Direct opening force *4
Direct opening travel *4
Holding force *5
Contact resistance
Minimum applicable load *6
Rated insulation voltage (U
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Impulse withstand
voltage
(EN60947-5-1)
Insulation resistance
Contact gap
Vibration resistance
Shock resistance
Conditional short-circuit current
Conventional free air thermal current (I
Ambient operations temperature
Ambient operations humidity
Weight
the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the
D4GL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
representative.
load beforehand.
2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however,
they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability
for smaller loads may be reduced.
Mechanical
Electrical
Between terminals of
same polarity
Between terminals of
different polarity
Between solenoid and
non-current carrying
metallic parts
Between other
terminals and
non-current carrying
metallic parts
Malfunction
Destruction
Malfunction
i
)
th
)
IP67 (EN60947-5-1)
1,000,000 operations min.
500,000 operations min. (4 mA resistive load at 24 VDC)
150,000 operations min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at
24 VDC, 2 circuits) *3
0.05 to 0.5 m/s
30 operations/minute max.
60 N min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
1,000 N min.
100 mΩ max.
4 mA resistive load at 24 VDC (N-level reference value)
300 V (EN60947-5-1)
50/60 Hz
Class II (double insulation)
3 (EN60947-5-1)
2.5 kV
4 kV
0.8 kV
4 kV
100 MΩ min. (at 500 VDC)
2 × 2 mm min.
10 to 55 Hz, 0.75 mm single amplitude
1,000 m/s
300 m/s
100 A (EN60947-5-1)
2.5 A (EN60947-5-1)
−10 to 55°C (with no icing)
95% max.
Approx. 400 g (D4GL-1AFA-A)