Specifications of CQM1-IPS01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CQM1IPS01
The CQM1H’s rack-less modular design lets
you customize your control system by adding
“inner boards” for advanced functions, as well
as specialized I/O and communications
modules. CQM1H offers the most flexibility of
all PLC systems in its class.
D
D
D
D
D
D
D
D
D
D
Basic Configuration
Select the CPU and I/O modules (discrete, analog and dedicated special function types) then determine the power supply based on the
current consumption. The I/O Control and Interface adapters give you the option of dividing the CPU and I/O system into two narrower
units than the examples shown below. The CQM1H-CPU51/CPU61 models offer space-saving position and motion control solutions as
well as additional analog and serial communications capabilities right at the CPU.
Power
Supply
CQM1H modules are assembled with connectors on their sides.
A--152
CQM1H
4 different base CPUs to choose from; 16 DC inputs
built in; expands up to 512 points
No separate backplane required
Inner Boards allow “customized” configuration of the
CPU
Serial communications inner board supports protocol
macro feature for communication with third-party serial
devices
Supports all existing and new CQM1 I/O and
specialized I/O modules
Optional memory cassettes allow backup of sensitive
data, provides a real-time clock
ControllerLink network transmits 8 kword data packets
at up to 2 Mbps; 32 nodes
Advanced instruction set includes PID, floating point
math, protocol macro instructions and more
CompoBus/S, SYSMAC BUS and AS-interface masters
support remote I/O
Up to 15.2 kwords of program memory
Programmable Controller
Controller
Link
Module
Programmable Controller
Inner
Boards
16 built-in
inputs
CQM1H
I/O Modules
and Dedicated
I/O Modules
End
Cover
CPU Unit
11 modules max. (16 modules max.
using I/O Expansion and Control In-
terface adapters). The total number
of words cannot exceed 16.
256 or 512 I/O points max.

CQM1-IPS01 Summary of contents

Page 1

... The I/O Control and Interface adapters give you the option of dividing the CPU and I/O system into two narrower units than the examples shown below. The CQM1H-CPU51/CPU61 models offer space-saving position and motion control solutions as well as additional analog and serial communications capabilities right at the CPU. ...

Page 2

... Programmable Controller International Part number standards CQM1H-CPU11 CQM1H-CPU21 CQM1H-CPU51 CQM1H-CPU61 International Part number standards CQM1-PA203 CQM1-PA206 CE CQM1-PA216 CQM1-PD026 International Part number standards CQM1H-ME16K CQM1H-ME16R CQM1-ME08K CQM1-ME08R CQM1-ME04K CQM1-ME04R CQM1-MP08K CQM1-MP08R L ROM-ID-B CE ROM-JD-B ROM-KD-B CQM1H A--153 ...

Page 3

... CQM1H International Part number standards CQM1H-IC101 CQM1H-II101 CS1W-CN313 CS1W-CN713 International Part number standards CQM1-ID211 U, C CQM1-ID111 CQM1-ID212 U, C CQM1-ID112 CQM1-ID213 CQM1-IA121 CQM1-IA221 International Part number standards CQM1-OC221 CQM1-OC222 CE, U CQM1-OC224 CQM1-OD211 CQM1-OD212 CQM1-OD213 CQM1-OD215 CQM1-OD214 CE CQM1-OD216 CQM1-OA221 CE CQM1-OA222 ...

Page 4

... Communications cycle time: 0.5 ms min. Max. transmission distance: 500 m in long-distance mode 100 m in high-speed mode Max. slaves per master: 32 Remote master Connects CQM1H to G730 SYSMAC BUS remote I/O SYSMAC BUS modules; max. 64 I/O ( inputs or outputs, DIP (*Use G730 modules switch selectable) ...

Page 5

... A--156 International standards For one Analog module For two Analog modules — — — CQM1H Part number CQM1-AD042 CQM1-AD041 , , , CQM1-DA022 CQM1-DA021 CQM1-IPS01 CQM1-IPS02 CQM1-B7A02 , CQM1-B7A12 CQM1-B7A03 CQM1-B7A13 CQM1-B7A21 CQM1-TC001 CQM1-TC002 CQM1-TC101 CQM1-TC102 , , CQM1-TC201 CQM1-TC202 CQM1-TC203 CQM1-TC204 CQM1-TC301 CQM1-TC302 CQM1-TC303 CQM1-TC304 CQM1-LSE01 ...

Page 6

... Cable length Cable length (for CPUs complying with EC direc- tives) Cable length Cable length Peripheral port conversion Connects the peripheral port on the CQM1H to a person- cable al computer or Programming Console through a CQM1-CIF02 cable. Communications Adapters and Cables Description Function Cables and adapters ...

Page 7

... Note: U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives J MANUALS Product Description Operation manual CQM1H CPUs and Inner Boards operation manual Programming manual CQM1H CPUs and Inner Boards programming manual Dedicated I/O Modules Covers analog input/output, B7A Link master, temperature controller, lin- manual ear sensor interface, and safety relay modules ...

Page 8

... The CPUs also vary in their program capacities, I/O capacities, memory capacities, and the presence of an RS-232C port, as shown in the Basic Specifications table, below. J NOMENCLATURE The following illustration shows the main components of a CQM1H-CPU61 CPU. Battery Compartment Cover Open this cover to access the battery, DIP switch, and Memory Cassette ...

Page 9

... I/O control method Cyclic scan and direct output/immediate interrupt processing Programming language Ladder-diagram programming I/O capacity CQM1H-CPU11/21: 256 CQM1H-CPU51/61: 512 Program capacity CQM1H-CPU11/21 : 3.2 kwords CQM1H-CPU51 CQM1H-CPU61 User data memory capacity CQM1H-CPU11/ kwords CQM1H-CPU51 CQM1H-CPU61 Instruction length 1 step per instruction words per instruction ...

Page 10

... These bits are allocated to the Inner Board mounted in slot 21515 CQM1H-CPU51/61. High-speed Counter Board: Serial Communications Board: IR 200 to IR 207 IR 22000 to Used to store the analog settings when a CQM1H-AVB41 IR 22315 Analog Setting Board is mounted. IR 23000 to Used to store the present values of high-speed counter 0. IR 23115 IR 23200 to These bits are allocated to the Inner Board mounted in slot 2 ...

Page 11

... Device). Stores various parameters that control PLC operation. — EM area data can be accessed in word units only. Word values are retained when the power is turned OFF or the operating mode is changed. (CQM1H-CPU61 CPU Unit only.) (This table continues on the next page.) CQM1H Controller Link parameters ...

Page 12

... Enables sending or receiving up to 256 bytes of data with- out a protocol or data conversion. A start code, end code, and transmission delay can be set. 1:1 data link Enables 1:1 data link with a CQM1H, CQM1, CPM-series, C200HX/HG/HE, C200HS, or SRM1 PLC. NT links Enables 1:1 or 1:N communications with OMRON Pro- (1:1 and 1:N) grammable Terminals without additional programming ...

Page 13

... Both AC and DC Power Supply Units are available. The AC Power Supply Units require a power supply input from 100 to 240 VAC and two of the AC Power Supply Units are equipped with an auxiliary 24 VDC power supply output. The CQM1H’s left End Cover is part of the Power Supply Unit. J SPECIFICATIONS Item CQM1-PA203 ...

Page 14

... Use Expansion I/O adapters to split the configuration into more than one group, allowing greater flexibility with mounting space as well as the use of at least 16 I/O Modules or Dedicated I/O Modules. Expansion Adapters can be used with any CQM1H CPU. J SPECIFICATIONS Maximum Number of Units Mountable ...

Page 15

... ROM version ROM-ID-B 27128 or equivalent ROM-JD-B 27256 or equivalent ROM-KD-B 27512 or equivalent Programmable Controller A--166 Flash Memory: CQM1H-ME16K CQM1H-ME16R Specifications 4 kwords without clock 4 kwords with clock 8 kwords without clock 8 kwords with clock Without clock (see below) With clock (see below) 16 kwords without clock 16 kwords with clock Mounted from the front of the CPU and used to store and read the user’ ...

Page 16

... IR 100. Input Words Built-in CPU inputs IR 000 (Fixed) (16 DC inputs) 32-point Input Module IR 001 IR 002 16-point Input Module IR 003 Output Words 8-point Output Module 16-point Output Module 16-point Output Module 16-point Output Module CQM1H Programmable Controller IR 103 IR 102 IR 101 IR 100 A--167 ...

Page 17

... OUT: 16 points modules d l IN: 32 points 2 OUT: 32 points IN: 64 points 4 OUT: 64 points Analog input module Analog output module — Analog power supply modules for — CQM1-AD041 and -DA021 Temperature 00j/10j control modules 20j/30j 1 Safety relay module 1 Programmable Controller A--168 Output Description words — ...

Page 18

... CQM1-ID212 16 pts Connector CQM1-ID112 32 pts CQM1-ID213 32 pts CQM1-ID214 32 pts AC Input Modules Model Number Input voltage inputs CQM1-IA121 8 pts 100 to 120 VAC +10%/15% CQM1-IA221 8 pts 200 to 240 VAC +10%/15% Model Model Number Number External connection External connection of inputs CQM1-IA121 8 pts Terminal block ...

Page 19

... R 2 CQM1-IA121 Input LED 470 Ω 68 kΩ Internal Circuits 0.15 µF 2.7 kΩ Programmable Controller A--170 CQM1-ID211 CQM1-ID112/213/214 CQM1-IA221 CQM1H Input LED 2.2 kΩ Internal 560 Ω Circuits Input LED Input LED : 750 Ω ID112 2.2 kΩ 620 Ω ...

Page 20

... CQM1-OD216 32 pts 0 VDC +10% (PNP, sourcing) / --15% Model Model Number of Number of Outputs/ Outputs/ outputs common CQM1-OD211 8 pts 8 (NPN, sinking) CQM1-OD212 16 pts 16 (NPN, sinking) CQM1-OD213 32 pts 32 (NPN, sinking) CQM1-OD214 16 pts 16 (PNP, sourcing) CQM1-OD215 8 pts 8 (PNP, sourcing) CQM1-OD216 32 pts 32 (PNP, sourcing) Note: Fuses are not user-serviceable. ...

Page 21

... VAC 240 VAC Fuses Fuses External power External power (See note) supply capacity 2 A — (one fuse/common — (one fuse/common) CQM1-OC222 Internal Circuits CQM1-OC224 Internal Circuits CQM1-OD214 Output LED Internal Circuits (Output Circuit Configuration continues on the next page.) CQM1H External ...

Page 22

... CQM1-OD216 Fuse 7 A Short-circuit protection circuit Output LED Short-circuit protection circuit Output LED CQM1-OA221 Output LED Internal Circuits CQM1-OA222 Output LED Internal Circuits Alarm output Reset input (Alarm output) CQM1H Programmable Controller Fuse 2 A Fuse 2 A Fuse 5 A Fuse 5 A ...