MAX9621AUB+T Maxim Integrated Products, MAX9621AUB+T Datasheet
MAX9621AUB+T
Specifications of MAX9621AUB+T
Related parts for MAX9621AUB+T
MAX9621AUB+T Summary of contents
Page 1
... Operates with ±3V Ground Shift Between the Hall S Sensor and the MAX9621 ±2kV Human Body Model ESD and ±200V Machine S Model ESD at All Pins 3mm x 5mm, 10-Pin µMAX Package S PART MAX9621AUB+T Applications +Denotes a lead(Pb)-free/RoHS-compliant package Tape and reel. ISET REFERENCE IN1 INPUT SHORT ...
Page 2
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs ABSOLUTE MAXIMUM RATINGS BAT to GND ...........................................................-0.3V to +60V ISET to BAT ..........................................................-2.0V to +0.3V IN1, IN2 to GND ................ -3V to lower of +60V or (V AOUT1, DOUT1, AOUT2, ...
Page 3
Dual, 2-Wire Hall-Effect Sensor Interface with DC ELECTRICAL CHARACTERISTICS (continued 13.6V 5V, IN1 = IN2 = no connection, R BAT SLEEP GND at AOUT1 and AOUT2, unless otherwise noted, T PARAMETER SYMBOL Input Referred Current Offset ...
Page 4
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs 14mA IN1 7mA 0mA 0.7mA AOUT1 0.35mA 0mA 5V DOUT1 0V Figure 1. Timing Diagram 14mA IN_ 7mA 0mA 5V DOUT_ 0V Figure 2. Hall Input Pulse Rejection 4 APPROXIMATELY ...
Page 5
Dual, 2-Wire Hall-Effect Sensor Interface with (V = 13.6V 61.9kI 5kI to GND at AOUT_, V BAT SET L BAT SUPPLY CURRENT vs OPERATING MODE BAT 0 -40NC A 0.8 0.7 0.6 ...
Page 6
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs (V = 13.6V 61.9kI 5kI to GND at AOUT_, V BAT SET L HALL INPUT CURRENT THRESHOLDS vs. ISET RESISTOR LOW TO HIGH ...
Page 7
Dual, 2-Wire Hall-Effect Sensor Interface with (V = 13.6V 61.9kI 5kI to GND at AOUT_, V BAT SET L CURRENT GAIN vs. SUPPLY VOLTAGE 0.07 0.06 0.05 0.04 0.03 5.50 SUPPLY VOLTAGE (V) RESPONSE TO SHORT ...
Page 8
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs PIN NAME Battery Power Supply. Connect to the positive supply through an external reverse-polarity diode. 1 BAT Bypassed to GND with a 0.1FF capacitor. Current Setting Input. Place a 1% ...
Page 9
Dual, 2-Wire Hall-Effect Sensor Interface with PIN NAME Open-Drain Output. Signal translated from Hall sensor 2. DOUT2 is high when the current flowing out of 6 DOUT2 IN2 exceeds the input current threshold high, and is low when less than ...
Page 10
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs Table 1. AOUT_/DOUT_ Truth Table CONDITION IN_ Short to GND IN_ Short to BAT or IN_ Open SLEEP Low V > 18V BAT *If IN_ is already shorted to BAT ...
Page 11
Dual, 2-Wire Hall-Effect Sensor Interface with V BAT 14V V IN_ 0V 11.5mA I IN_ 0A Figure 4. Hall Input Reenergized When Open Input Is Reconnected to Hall Sensor Sleep Mode Input (SLEEP) The MAX9621 features an active-low SLEEP input. ...
Page 12
Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs Figure 5. 3-Wire Hall-Effect Switches Configured as 2-Wire Table 2. A Partial List of Compatible Hall Switches PART NO. HAL573-6 HAL556/560/566 HAL579/581/584 A1140/1/2/3 A3161 TLE4941/C Sleep mode can be used ...
Page 13
Dual, 2-Wire Hall-Effect Sensor Interface with BATTERY: 5.5V TO 18V OPERATING, 60V WITHSTAND R SET ISET IN1 N 0.01 µ INPUT REMOTE SHORT GROUND DETECTION IN2 N 0.01 µ REMOTE GROUND Analog and Digital Outputs Typical ...
Page 14
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 14 © ...