X4K-Z1U-00011-A1 Digi International, X4K-Z1U-00011-A1 Datasheet

no-image

X4K-Z1U-00011-A1

Manufacturer Part Number
X4K-Z1U-00011-A1
Description
IDIGI GATEWAY DEV KIT ZIGBEE
Manufacturer
Digi International
Series
IDigi®r
Type
Transceiver, Z-Waver

Specifications of X4K-Z1U-00011-A1

Frequency
2.4GHz
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
ConnectPort® X4
Other names
602-1209
 
 
 
 
 
 
 
 
 
 
iDigi
 Gateway Development Kit 
®
Getting Started Guide
 
 
 
 
 
 
 
 
 
December 16, 2010 
90001205 _A 

Related parts for X4K-Z1U-00011-A1

X4K-Z1U-00011-A1 Summary of contents

Page 1

Getting Started Guide                   December 16, 2010  90001205 _A    ...

Page 2

All rights reserved.     Digi, iDigi, Digi International, the Digi and iDigi logos, ConnectPort, Digi ESP, iDigi Dia, XBee, Digi XBee  Smart Plug, iDigi Manager Pro, iDigi Web Services API, and a Digi International Company are trademarks  or registered trademarks of Digi International, Inc. in the United States and other countries worldwide.  All other trademarks are the property of their respective owners.     Information in this document is subject to change without notice and does not represent a commitment  on the part of Digi International.     Digi provides this document “as is,” without warranty of any kind, either expressed or implied, including,  but not limited to, the implied warranties of fitness or merchantability for a particular purpose. Digi may  make improvements and/or changes in this manual or in the product(s) and/or the program(s) described  in this manual at any time.     This product could include technical inaccuracies or typographical errors. Changes are periodically made  to the information herein; these changes may be incorporated in new editions of the publication.    iDigi Gateway Development Kit Getting Started Guide        2  ...

Page 3

Using this Guide  Contact Information   Please always check the product specific section on the Digi support website for the most  current revision of this document: http://www.digi.com/gatewaydevelopmentkit.    For more information about your Digi products, or for customer service and technical support,  contact Digi International.     To contact Digi International by  Mail  World Wide Web  Telephone (US)  Telephone (other locations)    Conventions used in this Guide  iDigi Gateway Development Kit Getting Started Guide       Use  Digi International  1101 Bren Road East  Minnetonka, MN  55343  U.S.A.  http://www.digi.com/support  (952) 912‐3444 or (877) 912‐3444  +1 (952) 912‐3444 or (877) 912‐3444      This icon indicates a step that has the potential to be  troublesome. Further information regarding items  marked with this symbol can be found in Appendix A:    Troubleshooting on page 60.      This icon indicates a hint, or concept that is learned.       This icon indicates that a goal of the kit has been  completed.    ...

Page 4

Contents  ® Introduction to the iDigi  Gateway Development Kit ................................................................................... 6  Goals of the Kit  . ......................................................................................................................................... 6  Requirements of the Kit ............................................................................................................................ 6  ® Part 1: Setup your Digi  Gateway Development Kit  . ..................................................................................... 7  Step 1: Kit Preparation  . ............................................................................................................................. 7  Step 2: Connect the ConnectPort X4 Step 3: Connect your ConnectPort Step 4: Install the Digi ESP™ for Python Development Environment ..................................................... 14  Step 5: Create your first iDigi Step 6: Perform an iDigi Web Services API™ Request ............................................................................ 38  ® Step 7: Using the iDigi  Gateway Development Kit Demonstration Application  . ................................... 45  Part 2: Learn More ...................................................................................................................................... 52  ® ® iDigi  Dia & iDigi  ..................................................................................................................................... 52  Digi ESP™ for Python  . .............................................................................................................................. 54  ® Digi’s  Gateway products ........................................................................................................................ 58  ® XBee ...

Page 5

Is the ASSC LED blinking green?  . ......................................................................................................... 60  iDigi Manager Pro™ does not discover your ConnectPort iDigi Manager Pro™ lists the ConnectPort® X4 as ‘Disconnected’  . ......................................................... 63  iDigi Gateway Development Kit Getting Started Guide       ®  X4 ............................................................... 61   5  ...

Page 6

Introduction to the iDigi Thank you for purchasing an iDigi Gateway Development Kit. The kit is designed to make it easy  to setup an XBee network, upload a custom iDigi Dia application, and provide seamless  connectivity to the iDigi platform for web services integration to standard business applications  over the Internet. Before you start working with the kit, let’s cover some basics.  Goals of the Kit  As you go through the steps in this kit, you will:  1. Create an iDigi developer account on the iDigi M2M operating platform.  2. Setup and configure the physical elements of an XBee wireless network and understand  how the network is managed through a ConnectPort X4 gateway.  3. Use the Digi ESP for Python IDE to build, download, and launch an iDigi Dia application  for your ConnectPort X4 gateway, then interact with the application in a realistic setting.  4. Use the iDigi Manager Pro Web Services Console to send a web service request to the  ConnectPort X4 retrieving the current XBee devices’ sensor readings.   5. Use the iDigi Gateway Development Kit Demonstration Application to understand how  an Enterprise application could use the iDigi Web Services API to monitor the data  gathered by the XBee devices’ sensors.  Requirements of the Kit  System Requirements   To install the software mentioned in the Getting Started Guide, you will need a PC running  Microsoft Windows XP, Vista or Windows 7. Web Browser Requirements   Microsoft Internet Explorer 7.0 or newer  Google Chrome 4.0 or newer  Mozilla Firefox 3.0 or newer  Additional Requirements   This Getting Start Guide assumes a scenario where there are no other XBee wireless devices in  the area (other than the ones provided with this kit) and that the local network has an Internet  connection.    Note: If other XBee networks are present and open for joining, the XBee Sensor and XBee Smart  Plug may join the wrong network. Please refer to the “XBee devices fail to join the ConnectPort  X4’s network” section of Appendix A: Troubleshooting on page 60 for more information.  iDigi Gateway Development Kit Getting Started Guide       ...

Page 7

Part 1: Setup your Digi Step 1: Kit Preparation  Identify Your Kit Components  Carefully unpack and verify the contents of your kit. Your kit should include each of the  following:  Download the Digi® Device Discovery Application  For proper kit configuration and operation, the Digi Device Discovery Application must be  downloaded and installed.   To download the Digi Device Discovery Application:  1. Navigate to http://www.digi.com/gatewaydevelopmentkit and then click on the  “Download Digi Device Discovery Application” link (within the Documentation tab).   2. Click the “Download your file” link and then follow the prompts to install the  application.    iDigi Gateway Development Kit Getting Started Guide        Gateway Development Kit  ®   Figure 1: Kit Contents    7  ...

Page 8

Step 2: Connect the ConnectPort X4 To begin setting up your iDigi Gateway Development Kit you will need to connect and power on  the ConnectPort X4, and form your XBee network.  To do so, follow these steps:  Note: If you have additional XBee/ZigBee devices, for the best kit experience, we recommend  that you power down or disable joining on other XBee/ZigBee PANs in the area before beginning  this step. If you are unable to do this other devices might join the kit network and create  interference when deploying your iDigi Dia project. You could also encounter issues connecting  the XBee Sensor and XBee Smart Plug to the ConnectPort X4 as they are configured to join any  available PAN.    1. Remove the ConnectPort X4 from the box and attach the XBee antenna to the  ConnectPort X4.  2. Connect one end of the Ethernet cable to the ConnectPortX4, and the other end to your  Ethernet switch (as shown below).    WARNING: If the ConnectPort X4 does not have access to the Internet this kit cannot be  completed.   iDigi Gateway Development Kit Getting Started Guide        to your Local Network  ®  Figure 2: Ethernet Switch       8  ...

Page 9

Connect the power supply to the ConnectPort X4 and then plug the power supply into a  wall outlet.   Note: The power supply has a twist‐locking connector, ensure that the connector is  locked into place.  4. Remove the XBee Smart Plug from the box and plug it into a wall outlet. The green LED  will blink to indicate that the XBee Smart Plug is associated with an XBee network.  5. Remove the batteries (3) from the box and install them into the XBee Sensor (unscrew  the two screws on the XBee Sensor to install the batteries). The XBee Sensor’s ASSC LED  will blink when the device is connected to your XBee network. Note: If either of the XBee devices fails to blink its ASSC LED indicating that it is connected to  your XBee network, please refer to the “Is the ASSC LED solid green? ” section of Appendix  A: Troubleshooting on page 60 for more information.  iDigi Gateway Development Kit Getting Started Guide           Figure 3: Setting up your ConnectPort X4    9  ...

Page 10

Step 3: Connect your ConnectPort The iDigi platform is an on‐demand hosted service platform with no infrastructure requirements  for the user. The iDigi platform provides device management, iDigi client application to iDigi  device data interaction (messaging), and data storage for a network comprised of both wired  and wireless Digi and third‐party Gateways (called iDigi devices). The iDigi platform provides  easy integration with M2M and mesh network devices.     First, before you can connect your ConnectPort X4 to iDigi, you must create an iDigi developer  account.     1. To set up an iDigi developer account:  a. Navigate to http://www.idigi.com.  b. Click on the iDigi Login button.  iDigi Gateway Development Kit Getting Started Guide        X4 to iDigi ® ® Figure 4: iDigi Home Page  Want to learn more about iDigi?  Please refer to the iDigi User’s Guide which can  be found at  http://www.digi.com/gatewaydevelopmentkit          10  ...

Page 11

If you do not already have an iDigi developer account, click on the “Are you a  new user" link and create your account.   If you already have an account, login and skip ahead to the “Add the  ConnectPort X4 to your iDigi inventory” section on the next page.  Continue filling in all required fields of the iDigi Registration Form until you  complete the iDigi Registration process.  d. After completing the iDigi Registration process, you will be redirected to the  iDigi Login page (refer to Figure 5, above). Enter your iDigi user credentials and  then click the Login button.       iDigi Gateway Development Kit Getting Started Guide         Figure 5: iDigi Login Page Figure 6: New User Registration Page  You have just completed Goal #1:  Creating an iDigi developer account on  the iDigi M2M operating platform.        11  ...

Page 12

Add the ConnectPort X4® to your iDigi® inventory  The iDigi platform allows you to securely manage the devices in your device inventory.     1. To add the ConnectPort X4 to your inventory, follow these steps:  a. Select the Devices link in the Left Navigation Bar.   b. Click the  applet. The Add Devices applet will discover the Digi devices on your network.   Note: In order to discover devices on your network automatically, the Add Devices applet  requires Java Runtime Environment (JRE) 1.6 or newer.    If Java Runtime Environment (JRE) 1.6 is not installed, you must add your device manually;  see the “iDigi Manager Pro does not discover your ConnectPort X4” section of Appendix A:  Troubleshooting, on page 61 for more information.  c. Select your ConnectPort X4 from the list. To verify that you are selecting the  correct device from the list, match the MAC address listed on your label (found  on the bottom of the device) with the MAC address listed within the Add  Devices applet. Click the OK button.   iDigi Gateway Development Kit Getting Started Guide       Add Devices button in the Tool Bar to open the Add Devices  Figure 7: Add Devices Applet     12  ...

Page 13

Wait about 60 seconds then go back to the Devices list and click the Refresh   button. The status of your ConnectPort X4 should now appear as “Connected.”    Note: If the device still appears as ‘Disconnected’ after clicking the Refresh button, please  refer to the “’iDigi Manager Pro lists the ConnectPort X4 as ‘Disconnected'” section of  Appendix A: Troubleshooting, on page 63 for more information.  iDigi Gateway Development Kit Getting Started Guide       Figure 8: iDigi Device Inventory       13  ...

Page 14

Step 4: Install the Digi ESP™ for Python Development  Environment  The Digi ESP for Python Development Environment is an Eclipse‐based Integrated Development  Environment (IDE) that simplifies the process of creating Python applications for iDigi devices.  It  also provides many example projects, one of which we will be using later in this section.  To download and install the Digi ESP for Python Development Environment:   1. Navigate to http://www.digi.com/gatewaydevelopmentkit and click on the “Download  Digi ESP for Python” link.   2. You will be redirected to the Python Product page. The various download options for  the Digi ESP for Python framework will be displayed on this page. Click on the “Digi ESP  for Python ‐ Windows XP/Vista/Windows 7 installer ver. 1.2.0.5” link to download the  Digi ESP for Python Development Environment.   Note: Mac operating systems are not supported in this Development Kit experience.   iDigi Gateway Development Kit Getting Started Guide       Figure 9: Select Digi ESP for Python Download Variant      14  ...

Page 15

Once the Digi ESP for Python framework has been downloaded, run the Digi ESP for  Python framework installation wizard. Follow the steps in the wizard to complete the  installation process. Click Finish at the end of the installation.  Note: A prompt will ask you if you would like to open the Release Notes associated with  the Digi ESP for Python framework, deselect this checkbox.   4. The Digi ESP for Python framework will launch automatically and prompt you to select a  workspace directory. Use the default workspace directory (or click the Browse button  and navigate to your desired alternate workspace location), check the “Use this as the  default and do not ask again” box, and click OK.   Note: The Digi ESP for Python framework 'workspace' is the directory where projects and  configurations will be stored. The default location for this directory is a subfolder called  workspace on the user home directory, for example, C:/Documents and  Settings/[username]/workspace.  iDigi Gateway Development Kit Getting Started Guide       Figure 10: Selecting your Digi ESP for Python Workspace     15  ...

Page 16

The first time you run Digi ESP for Python the Welcome screen is displayed.   6. Open the Digi ESP for Python Workbench by clicking on the Workbench icon (as  indicated above).     iDigi Gateway Development Kit Getting Started Guide       Figure 11: Digi ESP for Python Welcome Screen  Figure 12: Digi ESP for Python Workbench     16  ...

Page 17

Step 5: Create your first iDigi The iDigi Dia (Device Integration Application) is software written in Python that simplifies the  task of gathering data from attached devices (such as XBee Sensors), and sending the gathered  data to iDigi, allowing for easy integration with client applications using the iDigi Web Services  API to access it.    The steps in this section will help you build, download, and launch your first iDigi Dia application.      The resulting iDigi Dia application will contain drivers for the XBee Sensor and XBee Smart Plug.   The application will also be configured to report its data using the RCI presentation for access  with iDigi Web Services (which will be demonstrated later in this guide).      To begin creating your first iDigi Dia project:   1. Open the iDigi Dia Project Wizard by clicking File > New > iDigi Dia Project from the File  menu.    iDigi Gateway Development Kit Getting Started Guide        Dia Project  ®    Figure 13: Selecting an iDigi Dia Sample Project    17  ...

Page 18

The main wizard page contains a text box to insert the name of the project to be  created; name your project. This example uses a project name of “Demo_Project1” but  you can choose any unique name. Once the project name has been provided, click Next. iDigi Gateway Development Kit Getting Started Guide       Figure 14: Name your iDigi Dia Project        18  ...

Page 19

Within the Remote Device selection wizard page ensure that Use Current Remote  Configuration is selected, and then click the New… button to create a new remote  configuration. A new Remote Device Configuration is needed to work with each specific target device  (your ConnectPort X4 in this case). Multiple remote configurations can be created for  working with different devices.   iDigi Gateway Development Kit Getting Started Guide       Figure 15: Create New Configuration     19  ...

Page 20

After clicking the New… button, the Device Manager wizard dialog will open.  Note: The left side of the dialog lists the Remote Configurations that exist in the Workbench.   b. Initially, there are no Remote Configurations listed in the Device Manager. To begin  the process of creating your first Remote Configuration, enable the Device Manager  to discover the ConnectPort X4 automatically by clicking the Device Discovery          button.   iDigi Gateway Development Kit Getting Started Guide        Figure 16: Device Manager Home Page   20  ...

Page 21

A dialog will ask you to identify a location where the Digi ESP for Python framework  should look for devices. Select Local area network/USB devices and click OK.   d. When finished, the Digi Device Discovery dialog will appear listing all the Digi  devices discovered on your local network. Your device should be listed within the  dialog table.  e. Click on your device to select it from the list, and then click the Create Configuration  button.   iDigi Gateway Development Kit Getting Started Guide       Figure 17: Digi Device Discovery Search Location Selection Figure 18: Digi Device Discovery Applet        21  ...

Page 22

The new configuration will receive a generic name, “ConnectPort X4” in this case, with  all the settings configured automatically.     f. Click Set Current to make this configuration the current one, which means that the  Digi ESP for Python framework will use it to perform several operations that require  interaction with the remote device (reboot, transfer files, etc.).  iDigi Gateway Development Kit Getting Started Guide       Figure 19: Device Manager       22  ...

Page 23

After clicking the Set Current button you will be redirected back to the iDigi Dia Project  wizard. Ensure that Use Current Remote Device is selected, and click Next.  iDigi Gateway Development Kit Getting Started Guide         Figure 20: Remote Device Selection    23  ...

Page 24

Ensure that Python Interpreter version 2.4.3 is selected within the Python settings  section, and that iDigi Dia is supported then click Finish to create the project.   Note: If a prompt appears asking you to set a secure password click no.  iDigi Gateway Development Kit Getting Started Guide         Figure 21: Remote Device’s Information     24  ...

Page 25

Once the project is created the Smart Project Editor for iDigi Dia screen will be  displayed.   a. The created project is displayed in the  Pydev Package Explorer view; expand it to  see its contents. To open the Pydev  Package Explorer view, select Window >  Show View > Pydev Package Explorer. If  Pydev Package Explorer does not appear in  the list, select Other to open the Show  View dialog.    Note: Depending on your screen’s  resolution, it may be helpful to maximize  the Digi ESP for Python Screen. iDigi Gateway Development Kit Getting Started Guide        Figure 22: Smart Project Editor for iDigi Dia Screen             Figure 23: Pydev Package Explorer                                                    25  ...

Page 26

The main file of the project, dia.yml, will be opened and displayed in the Smart  Project Editor view. It contains the iDigi Dia elements (devices, services, etc.)  that will be used by the iDigi Dia project.  iDigi Gateway Development Kit Getting Started Guide        Figure 24: Smart Project Editor View   26  ...

Page 27

The XBee Sensor and XBee Smart Plug need to be added to your project via the iDigi Dia  Project Editor. To add these items, perform the following steps:   a. Click the Add… button to begin adding your XBee devices.  b. For the XBee Senor, select “XBee Sensor” from the Devices category, then click  the Add button.  Repeat this process for the XBee Smart Plug by selecting “XBee RPM” from the  Devices category and then clicking the Add button.    Note:  For non‐US kits, select the “XBee Wall Router” instead of XBee RPM.  8. At this point in time the two XBee devices have been added to your project, but the iDigi  Dia Project Editor is missing the XBee MAC addresses for your XBee Sensor, and XBee  Smart Plug.  The XBee MAC address information for your XBee devices can be determined by  connecting to the web UI of the ConnectPort X4.   Note: If you already know the IP address of your ConnectPort X4 Gateway open a web  browser and type in the IP address, and move onto Step 12. Otherwise, use the Digi Device  Discovery tool (described in the next step).   iDigi Gateway Development Kit Getting Started Guide        Figure 25: Missing MAC Addresses   27  ...

Page 28

Run the Digi Device Discovery Tool from your PC's Start Menu.   10. Running the Digi Device Discovery Tool will bring up the Digi Device Discovery  Application Devices list.    Locate your device in the list and double‐click on it to bring up the ConnectPort X4  Home page.   iDigi Gateway Development Kit Getting Started Guide          Figure 26: Device Discovery Path Figure 27: Locate your Device in the Device List        28  ...

Page 29

Figure 28: ConnectPort X4 Configuration and Management Home Page  11. The ConnectPort X4’s Home page contains several links. Click on the XBee Network link  from the left menu to access the XBee Configuration page.   iDigi Gateway Development Kit Getting Started Guide           Figure 29: XBee Network Option    29  ...

Page 30

The XBee Configuration page shows the network view of the XBee devices attached to  the ConnectPort X4. Verify that your XBee L/T Sensor, ConnectPort X4, and XBee Smart  Plug are all listed (as shown below).   If your XBee L/T Sensor, ConnectPort X4, and/or XBee Smart Plug are not listed, try  clicking the Discover XBee Devices button to force the ConnectPort X4 to discover its  attached XBee devices.   If this does not fix the problem, see the “XBee devices fail to join the ConnectPort X4’s  XBee network” section of Appendix A: Troubleshooting on page 60 for more  information.    iDigi Gateway Development Kit Getting Started Guide         Figure 30: XBee Network View You have just completed Goal #2:  Setting up and configuring the physical  elements of an XBee wireless network, and  understanding how the network is managed  through a ConnectPort X4 gateway.     30  ...

Page 31

Now you need to configure the Smart Project Editor with the MAC addresses of the two  XBee devices that were added to this project in Step 7 (above).  To do that, simply copy  the XBee Extended Address from the ConnectPort X4's web UI (as shown in Figure 30)  into the appropriate MAC address field within the Smart Project Editor.  a. Copy the Extended Address of your XBee /L/T Sensor from the ConnectPort X4's  web UI into the MAC address field of the XBee Sensor device in the Smart  Project Editor.  b. Then copy the Extended Address of your XBee Smart Plug from the ConnectPort  X4's web UI into the MAC address field of the XBee RPM device in the Smart  Project Editor (as shown below).  Note:  For non‐US kits, select the “XBee Wall Router [xbr0]” instead of XBee RPM.    With the MAC addresses updated in the Smart Project Editor, all configuration errors  (missing XBee MAC addresses for your XBee Sensor and XBee Smart Plug) should be  cleared.  iDigi Gateway Development Kit Getting Started Guide         Figure 31: Enter MAC Address  31  ...

Page 32

Note: The XBee Sensor's default sleep interval is one minute.  Changing the Sample Rate  configuration value to 5000 will set the sleep interval to five seconds, which will provide  sensor updates more often. These sensor updates will allow you to see value changes  more easily in the steps to follow. However, changing the sleep interval will impact  battery life as well. This is something you should take into consideration when deploying  your devices.   14. Change the Sample Rate parameter of the XBee Sensor from 60000 to 5000 (as shown  below).  iDigi Gateway Development Kit Getting Started Guide        Figure 32: Change Sleep Interval Sample Rate      32  ...

Page 33

Save your project by clicking the Save button from the main toolbar, or navigating to  File > Save from the menu.  16. Now that the XBee MAC addresses have been configured your iDigi Dia project is fully  configured and ready to be deployed. Click the Run       button (on the main toolbar)  then select the Remote iDigi Dia option, and click OK to continue.  iDigi Gateway Development Kit Getting Started Guide       Figure 33: Save Project  Figure 34: Launch your Project         33  ...

Page 34

The Source View at the bottom of the Workbench screen will display status messages as  the:  iDigi Dia project builds,  Downloads files to your ConnectPort X4,  Reboots your ConnectPort X4 (in order to start the Dia application),  and finally starts running the Dia application on your ConnectPort X4.    Note: This process takes a minute or so, please be patient.   iDigi Gateway Development Kit Getting Started Guide           Figure 35: Workbench Source View  34  ...

Page 35

The workbench will now display an additional tab, the Dia Web Presentation tab, and  your screen will look similar to the following:  The Elements section of the Smart Project Editor for iDigi Dia provides several  presentations including an RCI Handler, Console Port, and a Web Presentation. For more  information on these items, refer to the “Digi ESP for Python” section of Part 2: Learn  More, on page 54.  iDigi Gateway Development Kit Getting Started Guide         Figure 36: Dia Web Presentation Tab    35  ...

Page 36

After the iDigi Dia project (created throughout “Step 5: Create your first iDigi Dia  Project” of this guide) starts running on your ConnectPort X4, you can interact with the  XBee devices by accessing the /idigi_dia.html web page directly from the web UI of the  ConnectPort X4.  To interact with the new web page, open your web browser and enter the IP address of  your ConnectPort X4, followed by the “/idigi_dia.html” page (as demonstrated below  using the example “http://10.21.6.178/idigi_dia.html”).   From this page you can turn the XBee Smart Plug off and on, as well as view all the  current sensor readings. In order to demonstrate how this web page can control the  power to a remote device, connect a lamp, fan, or some other electrical device to the  power outlet on the XBee Smart Plug.  a. In the example above, the XBee Smart Plug’s power_on state is currently turned  “On”.  To turn the XBee Smart Plug off, simply replace the “On” with “Off” in the  Value column, then click the Apply Changes button.   b. The XBee Smart Plug will turn off, and the ConnectPort X4’s web page will be  updated to show the current power_on state of the XBee Smart Plug.  iDigi Gateway Development Kit Getting Started Guide        Figure 37: XBee Smart Plug – Power ON    36  ...

Page 37

To turn the XBee Smart Plug on, simply type “On” in the Value field and click the  Apply Changes button.  d. To update the values displayed by the XBee devices’ sensors, click the Refresh  All button.      iDigi Gateway Development Kit Getting Started Guide        Figure 38: XBee Smart Plug – Power OFF    You have just completed Goal #3:  Using the Digi ESP for Python IDE to build,  download, and launch an iDigi Dia application for  your ConnectPort X4 gateway, and then interacting    with the application in a realistic setting.     37  ...

Page 38

Step 6: Perform an iDigi Web Services API™ Request  The next step in the process of using your iDigi Gateway Development Kit is performing an iDigi  Web Services API request using iDigi Manager Pro. The iDigi Web Services Console makes it easy  to send web service requests to your iDigi device. This example will demonstrate how to retrieve  sensor readings from your XBee Sensor and XBee Smart Plug by making a minor modification to  one of the provided examples, and then sending an HTTP Post request to iDigi, which will  respond with the current sensor readings from the sensors in your XBee devices.   The following steps will walk you through performing this API request.    1. Log in to your iDigi developer account.  2. In the Left Navigation Bar under the Management section, select the Web Services  Console link.    3. Click on the SCI Targets button within the Web Services Console toolbar.   iDigi Gateway Development Kit Getting Started Guide       Figure 39: Digi Manager Pro Web Services Console Page  Figure 40: SCI Targets Button       38  ...

Page 39

Clicking this button will bring up the Select devices to be used in examples dialog box.  Within this box you will select the target iDigi devices that you would like to send  requests to.    5. Click on the Add Targets drop‐down box, and choose the device ID corresponding to  your ConnectPort X4. Click the Add button                and then click OK.  iDigi Gateway Development Kit Getting Started Guide       Figure 41: Add Targets    Figure 42: Targets Successfully Added       39  ...

Page 40

Within the Web Services Console toolbar click on the  Examples drop‐down menu then  go to SCI > Python Callback.    iDigi Gateway Development Kit Getting Started Guide         Figure 43: Python Callback     40  ...

Page 41

Once you have selected  the SCI Python Callback example, iDigi Manager Pro will  populate the page with the source code of the example as well as select the HTTP  method that will be used (an HTTP Post in this case).  In order for you to retrieve the  sensor readings from your XBee devices, you will need to modify this example text  slightly.   a. Locate the following lines of text (highlighted in the screenshot below)  <do_command and replace them with the following:  <do_command Note: "idigi_dia" is the Target Name listed in the RCI Handler Presentation (as  mentioned on page 35).    iDigi Gateway Development Kit Getting Started Guide       target="rci_callback_example"> ping target="idigi_dia"> <channel_dump/> Figure 44: SCI Python Callback Example    41  ...

Page 42

Your screen should look similar to the one below.  Click the Send button to send this  request to iDigi. The first time you send a web services request to iDigi, you will be  prompted to enter your iDigi credentials, enter them in the dialog provided. Once  authenticated, iDigi will send this request to the ConnectPort X4 on behalf of your web  services request and display the response from the ConnectPort X4 in the Web Services  Responses panel.          iDigi Gateway Development Kit Getting Started Guide         Figure 45: Updated SCI Callback Example  42  ...

Page 43

Observe the output displayed within the Web Services Responses panel. A "POST  /ws/sci 200” response indicates that the web services request was successful.   iDigi Gateway Development Kit Getting Started Guide         Figure 46: Successful Callback Attempt  43  ...

Page 44

Click on the "POST /ws/sci 200” response text to view the entire response from the  ConnectPort X4, as well as the request that was sent to generate this response. The  channel_dump response shows the current usage, brightness, power‐on state, and  temperature readings from the rpm0 (XBee Smart Plug) device, and the brightness,  battery condition, and temperature reading from the sensor0 (XBee Sensor) device.    iDigi Gateway Development Kit Getting Started Guide       Figure 47: Successful Callback Expanded View        You have just completed Goal #4:  Using the iDigi Manger Pro Web Services  Console to send a web services request to  the ConnectPort X4, retrieving the current  XBee devices’ sensor readings.      44  ...

Page 45

Step 7: Using the iDigi Application  The final step in the process of taking advantage of what this Development Kit offers, is  accessing the iDigi Web Services API via the iDigi Gateway Development Kit Demonstration  Application.  The following steps will walk you through this process.  1. Navigate to http://www.digi.com/gatewaydevelopmentkit and click on the “Link to iDigi  Gateway Development Kit Demo Application” link.  2. You will be redirected to the iDigi Gateway Development Kit Demonstration Application  login page. Enter your iDigi username and password, as well as the last 6 characters of  your Gateway ID, into the appropriate fields and then click the Login button.  Figure 48: iDigi Gateway Development Kit Demonstration Application Login Page iDigi Gateway Development Kit Getting Started Guide        Gateway Development Kit Demonstration  ®    45  ...

Page 46

After logging in, the demonstration application will display a screen similar to the following: Figure 49: iDigi Gateway Development Kit Demo Application  Getting familiar with the iDigi Gateway Development Kit Demonstration Application  This demonstration application displays the current sensor readings and logged sensor readings  for the XBee Sensor and the XBee Smart Plug connected to your ConnectPort X4’s XBee  network. Values are updated by clicking the refresh button. Every time the screen is refreshed  the application also updates the time‐stamp information at the top of the screen.  Logging begins automatically once you log in to the application, and logged data is collected  once a minute for 60 minutes. After the 60 samples are collected, logging stops. To collect more  samples, simply log out, and then log back in to the demonstration application.  iDigi Gateway Development Kit Getting Started Guide            46  ...

Page 47

XBee® Sensor:  The XBee Sensor has an internal light and temperature sensor. The last reported readings from  both internal sensors are reported.    In the event that your brightness reading looks similar to the example above, simply cover the  light sensor on the front of the XBee Sensor and click the Refresh button, and you should see  something similar to the following:  iDigi Gateway Development Kit Getting Started Guide        Figure 50: XBee Sensor Display  Figure 51: XBee Sensor Display Refreshed     47  ...

Page 48

TM XBee Smart Plug   (for US kits only):  The XBee Smart Plug has an internal light and temperature sensor. It also has the ability to track  its current usage and allows the XBee Smart Plug to be turned on or off. This demonstration  application displays the current flowing through the XBee Smart Plug and the On/Off state of  the XBee Smart Plug.    In the event your XBee Smart Plug displays something similar to the output above, simply click  the “Off” button, and then click Refresh. Your XBee Smart Plug should display something similar  to the following:  iDigi Gateway Development Kit Getting Started Guide       Figure 52: XBee Smart Plug Display ‐ Current Flowing  Figure 53: XBee Smart Plug Display ‐ No Current Flowing    48  ...

Page 49

Logged Data:  The logged data area displays up to the last 60 sensor readings from all XBee device sensors.  Logging will stop automatically after an hour and data will be discarded after 24 hours. In order  to update the Telemetry data, click the Refresh button.  When you log in to this demonstration application, Telemetry logging will start automatically  and run for an hour. Since the logged data is collected once every 60 seconds and only 60  samples are logged, you may need to wait up to 2 minutes before the Telemetry data is updated  (as shown in the example below).  iDigi Gateway Development Kit Getting Started Guide       Figure 54: Logged Data Display – Off  Figure 55: Logged Data Display – Begin Logging      49  ...

Page 50

By turning off the XBee Smart Plug and covering the light sensor on the XBee Sensor, a  subsequent screen refresh should make the Telemetry data look similar to the following Figure 56: Logged Data Display – XBee Smart Plug Off, XBee Sensor Covered Waiting a few moments before turning the XBee back on, and uncovering the light sensor on the  XBee Sensor should make the Telemetry data look similar to the following:  Figure 57: Logged Data Display – XBee Smart Plug On, XBee Sensor Uncovered iDigi Gateway Development Kit Getting Started Guide       :        50  ...

Page 51

By clicking on one of the gauges or graphs, the application will display a more detailed view as  shown below:   Congratulations you have completed the process of setting up your  iDigi Gateway Development Kit!  Please read through the “Part 2: Learn More” section of this guide to learn more about the Digi devices  and applications used throughout the process of setting up your iDigi Gateway Development Kit.  iDigi Gateway Development Kit Getting Started Guide       Figure 58: Graph Expanded View  You have just completed Goal #5:  Using the iDigi Gateway Development Kit  Demonstration Application to understand how a  web services enabled Enterprise application  interacts with iDigi and monitors the data  gathered by the XBee device’ sensors.      51  ...

Page 52

Part 2: Learn More  iDigi  Dia & iDigi    ® ® Going to Market?  Many users of the iDigi developer platform are creating M2M applications they intend to launch  as commercial applications. Taking advantage of the iDigi production platform with unlimited  scalability, high‐availability and industry leading security is easy as 1 ‐ 2 ‐ 3.  1. Contact Digi Business Development and express your desire for an iDigi Production  Account at 1‐877‐IDIGI‐EZ or by email at http://www.idigi.com/contactus/#email.  2. A Digi Business Development Representative will send you a copy of the iDigi Terms of  Service and review pricing.  3. Sign the Terms of Service and an iDigi production account will be created and log‐in  credentials will be emailed to you.  Since iDigi is an on‐demand platform as a service, you will only be charged for what you use.   Further support can be accessed through our support portal at:   http://www.digi.com/support/?kw=idigi.  iDigi Dia is designed upon a tested architecture that provides the core functions of remote  device data acquisition, control, and presentation between devices and information platforms. It  collects data from any device that can communicate with a Digi gateway, and is supported over  any gateway physical interface. iDigi Dia presents this data to upstream applications in fully  customizable formats, significantly reducing a customer's time‐to‐market.     Written in the Python programming language for use on Digi devices, iDigi Dia may also be  executed on a PC for prototyping purposes when a suitable Python interpreter is installed.    iDigi Gateway Development Kit Getting Started Guide         The iDigi platform is a Machine to Machine (M2M) network operating  platform, used by software developers and organizations responsible  for supporting the network. It enables secure, reliable M2M delivery  from your remote devices to your enterprise application.    iDigi  ...

Page 53

Further documentation on iDigi Dia and iDigi can be found within the iDigi Manager Pro  Resources link. Once logged in to iDigi Manager Pro, click on the Resources link in the Left  Navigation Bar and explore the documents listed under the “iDigi Dia Resources” and “iDigi  Platform Resources” headings.  Additional documentation can also be found on the product specific section of the Digi website  http://www.digi.com/gatewaydevelopmentkit, under the “Support Documentation” heading of  the Documentation tab.                iDigi Gateway Development Kit Getting Started Guide          Figure 59: iDigi Dia and iDigi Documentation    Figure 60: Support Documentation  53  ...

Page 54

Digi ESP™ for Python   Digi ESP for Python documentation can be found within the Digi ESP for Python framework  program. To locate this documentation:  1. Navigate to the Digi ESP for Python Welcome page and click on the Overview button.  Once the Python overview screen is displayed, click on the “Digi ESP for Python”  framework link and browse the documentation contained within this page.    iDigi Gateway Development Kit Getting Started Guide       Digi ESP for Python is an Integrated Development Environment (IDE)  that allows the developer to easily develop applications in Python. Digi  ESP for Python is built on Eclipse and the Python Development  Environment (Pydev) plug‐in. Eclipse is an open, extensible IDE. It was  originally written for Java development. The Pydev is a plug‐in that  provides support for developing applications with Python in the Eclipse  platform. Digi ESP for Python customizes Eclipse and PyDev to support  developing specifically with Digi platforms.  Figure 61: Welcome Screen Overview Button  Figure 62: Digi ESP for Python Overview          54  ...

Page 55

Additional help documentation can be located by navigating to Help > Help Contents  from the Digi ESP for Python framework main menu.   iDigi Gateway Development Kit Getting Started Guide       Figure 63: Help Contents Path  Figure 64: Digi ESP for Python Help Section        55  ...

Page 56

The Elements section of the Smart Project Editor for iDigi Dia provides several presentations  including an RCI Handler, Console Port, and a Web Presentation. The Web Presentation (iDigi  Dia project) described in this guide provides details for a new web page “idigi_dia.html.” Click on  the Dia Web Presentation tab to open this new web page.  The iDigi Dia project also provides support for a new Console Port (using TCP Port 4146 as  detailed below).  iDigi Gateway Development Kit Getting Started Guide         Figure 65: Dia Web Presentations  56  ...

Page 57

To use the new Console Port, establish a Telnet connection to your ConnectPort X4 using TCP  port 4146, and the iDigi Dia CLI will be presented to you.  The “?” will provide a list of the supported CLI commands, and the “channel_dump” command  will retrieve the current sensor readings from your XBee devices’ sensors.  iDigi Gateway Development Kit Getting Started Guide         Figure 66: New Console Port  Figure 67: Establish a Telnet Connection       57  ...

Page 58

Digi’s  Gateway products  ® Gateway Functionality  The gateways function, as the name implies, as gates between local mesh networks (e.g.  ZigBee) and IP‐based networks (e.g. Cellular). The gateways support the following network  protocols:   PAN Networks: - ZigBee  - DigiMesh 2.4 GHz  - DigiMesh 900 MHz     IP Networks:  - Ethernet  - WiFi  - 2G/3G/4G Cellular  - WiMax  - Satellite     Programmability  ConnectPort X Gateways support the Python programming language and offer the memory  space for local development. This allows the gateways to function with enough local  intelligence to make decisions about which events are worth communicating over the wide  area network. This is especially useful when sending traffic over proprietary cellular or  satellite networks.  iDigi Dia (described above) further enhances the value of custom programming on Digi  gateways by offering an expanding library of Python plug‐ins to support and manage  communication between many common device types and iDigi.  For more information regarding ConnectPort X Gateways please go to:  http://www.digi.com/products/wirelessdropinnetworking/connectportxgateways.jsp  iDigi Gateway Development Kit Getting Started Guide     ...

Page 59

XBee  Sensor  ®     Digi XBee Sensors are compact, battery powered environmental sensors for  ZigBee networks. They provide real‐time temperature and light information  for a variety of applications.       For more information regarding XBee Sensors please go to:  http://www.digi.com/products/wirelessdropinnetworking/sensors/xbee‐sensors.jsp  XBee Smart Plug™ (or XBee   The Digi XBee Smart Plug is an intelligent outlet that has the ability to  measure and control electrical devices plugged in via a standard electrical  outlet. The XBee Smart Plug and XBee Wall Router have integrated light and  temperature sensors. Both devices are XBee routers and extend the range of  a ZigBee Network.      For more information regarding the XBee Smart Plug go to:  http://www.digi.com/products/wirelessdropinnetworking/networkextenders/xbee‐smart‐plug‐ zb.jsp  For more information regarding the XBee Wall Router go to:  http://www.digi.com/products/wireless/zigbee‐mesh/xbee‐wall‐router.jsp  Digi’s  ZigBee RF Modules  ® The ConnectPort X4, XBee Sensor, and XBee Smart Plug/XBee Wall Router used in this kit each  contain a ZigBee RF module built on Digi’s XBee hardware platform. Utilizing the ZigBee wireless  standard, these modules are interoperable with other ZigBee devices, including devices from  other vendors. Programmable versions of the XBee‐PRO ZB module make customizing ZigBee  applications easy, even without wireless design expertise.  If you are interested in learning more about Digi’s XBee and XBee‐PRO ZB modules, we  encourage you to purchase a Digi ZigBee RF Module Development Kit from www.digi.com or  your Digi authorized reseller.  iDigi Gateway Development Kit Getting Started Guide        Wall Router in non­US kits)  ® ...

Page 60

Appendix A: Troubleshooting   XBee  devices fail to join the ConnectPort X4’s XBee ® Is the ASSC LED solid green?  If the ASSC LED is solid green on the XBee Sensor, XBee Smart Plug, or XBee Wall Router, it  indicates that the XBee device is waiting to join a network, but has been unable to do so (once it  joins it will blink its ASSC LED). This condition may mean one of two things; the ConnectPort X4  is turned off, or the XBee device is out of range of the ConnectPort X4.    To troubleshoot this problem, move the XBee device closer to the ConnectPort X4 and/or  ensure that the XBee device is turned on.  Is the ASSC LED blinking green?  The XBee Sensor, XBee Smart Plug, or XBee Wall Router will blink their ASSC LED when they are  attached to a ZigBee network. If the XBee device has a blinking ASSC LED, but the device does  not appear in the list of XBee devices connected to the ConnectPort X4, then the XBee device  has either connected to the wrong ZigBee network, or the ConnectPort X4 simply needs to  rediscover the list of its attached XBee devices.  To troubleshoot this problem, first try clicking the Discover XBee Devices button on the  ConnectPort X4's XBee Network page as described on page 30. If this is unsuccessful, move the  XBee device closer to the ConnectPort X4 (and if possible configure the devices on the other  XBee network to block network joins).   Once the XBee device has been moved closer to the ConnectPort X4, factory reset the XBee  device (in order to force the XBee device to go through its XBee network discovery phase again).   To factory reset an XBee device, simply press the reset button on the side of the unit 4 times (at  a rate of 2 times per second). Once this is done, the XBee device should connect to the  ConnectPort X4's XBee network, and then show up in its list of attached XBee devices (as  described on page 30).  If this fixes the problem, return to the “Step 5: Create your first iDigi Dia Project” section and  proceed with Step 12 on page 30.  If your devices still are not appearing in the XBee devices list, please contact Digi’s Technical  Support (see Contact Information on page 3).      iDigi Gateway Development Kit Getting Started Guide        network  ®  60  ...

Page 61

If it is not practical to install JRE 1.6 or newer on your PC in order to allow the auto‐discovery  process to properly configure your ConnectPort X4 to communicate with iDigi, you can configure  the device manually by following these steps:  1. Add the ConnectPort X4 to your iDigi inventory by clicking the Add Manually button and  then entering the MAC address (found on the bottom of the device) into the  appropriate field.  After the MAC address is entered, click the Add button.   2. After your ConnectPort X4 MAC address entry appears in the list, click the OK button to  add the device to your iDigi inventory.     Note: When entering a MAC address use the following format XXXXXX:XXXXXX.       iDigi Gateway Development Kit Getting Started Guide       Figure 68: Manually Adding a Device to your iDigi Inventory   X4  ®    61  ...

Page 62

At this point in time, the ConnectPort X4 has been added to your iDigi inventory, but the  device itself has not yet been configured to establish a connection to iDigi. To configure  the ConnectPort X4 to establish a connection to iDigi, follow the steps below.   a. If you know the IP address of the ConnectPort X4, connect to its web UI by  entering its IP address in your web browser.    If you do not know the IP address of the unit, use the Digi Device Discovery tool  in the Start Menu, and double‐click on the device to open its web UI.  b. Click the iDigi link to configure the device’s remote management configuration  options. In the Digi configuration settings page, enter the DNS name of the iDigi  platform (developer.idigi.com) into the iDigi Server Address field under the  “Enable Device‐Initiated iDigi Connection” section.  c. Click the checkbox labeled “Automatically reconnect to iDigi after being  disconnected” then click Apply.    The ConnectPort X4 will now attempt to establish a connection with iDigi, if the device is on a  network with Internet access, the connection should be established in less than a minute. With  the ConnectPort X4 properly configured to communicate with iDigi, and with the device added  to your iDigi inventory, return to the “Add the ConnectPort X4 to your iDigi inventory” section  and proceed with Step d on page 13.  iDigi Gateway Development Kit Getting Started Guide       Figure 69: iDigi Configuration Page      62  ...

Page 63

This condition indicates that the ConnectPort X4 and iDigi are not communicating with one  another.  This can occur for several reasons:  1. The ConnectPort X4 is not connected to the network, or is on a network that does  not have Internet access.  2. The ConnectPort X4 is unable to resolve the DNS address of "developer.idigi.com."  3. If you added the ConnectPort X4 to iDigi inventory manually, the MAC address  provided to iDigi may not match the actual MAC address of the ConnectPort X4.   4. The ConnectPort X4 is not configured to establish a connection with iDigi.  If you have verified that all four of these scenarios are not occurring please contact Digi’s  Technical Support (see Contact Information on page 3).  iDigi Gateway Development Kit Getting Started Guide        63  ...

Related keywords