5.7 g-range selection
Register (0x0F) contains the selection of the g-range. Proper settings for (0x0F) range are
´0011b´ (selects ±2g range), ´0101b´ (selects ±4g range), ´1000b´ (selects ±8g range), ´1100b´
(selects ±16g range). All other settings are irregular; if such a setting is used, ±2g range is
selected. Default value of (0x0F) range (after reset) is ´0011b´.
Table 35: g-range, register (0x0F)
Bit 7
Bit 6
Bit 5
reserved
reserved
reserved
5.8 Bandwidths
Register (0x10) contains the selection of the bandwidth for filtered acceleration data. Settings
for (0x10) bw are ´00xxxb´ (bandwidth = 7.81 Hz), ´01000b´ (bandwidth = 7.81 Hz), ´01001b´
(bandwidth = 15.63 Hz), ´01010b´ (bandwidth = 31.25 Hz), ´01011b´ (bandwidth = 62.5 Hz),
´01100b´ (bandwidth = 125 Hz), ´01101b´ (bandwidth = 250 Hz), ´01110b´ (bandwidth = 500
Hz), ´01111b´ (bandwidth = 1000 Hz), ´1xxxxb´ (bandwidth = 1000 Hz). Default value of (0x10)
bw (after reset) is ´11111b´. It is recommended to actively use the range from ´01000b´ to
´01111b´ only in order to be compatible with future products.
Table 36: Bandwidths, register (0x10)
Bit 7
Bit 6
Bit 5
reserved
reserved
reserved
5.9 Power modes
Register (0x11) contains the configuration of the power modes. (0x11) suspend = ´1´ (´0´) sets
(resets) suspend mode; default value of (0x11) suspend is ´0´.
(0x11) lowpower_en = ´1´ (´0´) sets (resets) low-power mode, default value of (0x11)
lowpower_en is ´0´.
The settings for (0x11) sleep_dur are ´0000b´ to ´0101b´ (sleep phase duration = 0.5 ms),
´0110b´ (sleep phase duration = 1 ms), ´0111b´ (sleep phase duration = 2 ms), ´1000b´ (sleep
phase duration = 4 ms), ´1001b´ (sleep phase duration = 6 ms), ´1010b´ (sleep phase duration =
10 ms), ´1011b´ (sleep phase duration = 25 ms), ´1100b´ (sleep phase duration = 50 ms),
´1101b´ (sleep phase duration = 100 ms), ´1110b´ (sleep phase duration = 500 ms), ´1111b´
(sleep phase duration = 1 s). Default value of (0x11) sleep_dur is ´0000b´.
Table 37: Power modes, register (0x11)
Bit 7
Bit 6
Bit 5
suspend
lowpower
reserved
_en
Rev. 1.0
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
BMA250
Data sheet
Bit 4
Bit 3
Bit 2
reserved
range
range
<3>
<2>
Bit 4
Bit 3
Bit 2
bw <4>
bw <3>
bw <2>
Bit 4
Bit 3
Bit 2
sleep_
sleep_
sleep_
dur<3>
dur<2>
dur<1>
Page 41 / not for publishing
Bosch Sensortec
Bit 1
Bit 0
range
range
<1>
<0>
Bit 1
Bit 0
bw <1>
bw <0>
Bit 1
Bit 0
sleep_
reserved
dur<0>