BMA250 Bosch Sensortec, BMA250 Datasheet - Page 42

3-AXIS ACCELEROMETER DIGITAL I/F

BMA250

Manufacturer Part Number
BMA250
Description
3-AXIS ACCELEROMETER DIGITAL I/F
Manufacturer
Bosch Sensortec
Series
-r
Datasheets

Specifications of BMA250

Featured Product
BMA250 - Digital, Triaxial Acceleration Sensor
Axis
X, Y, Z
Acceleration Range
±2g, 4g, 8g, 16g
Sensitivity
256LSB/g, 128LSB/g, 64LSB/g, 16LSB/g
Voltage - Supply
1.62 V ~ 3.6 V
Output Type
I²C™, SPI™
Bandwidth
8Hz ~ 1kHz
Interface
I²C, SPI
Mounting Type
Surface Mount
Package / Case
12-VQFN
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
828-1024 - BMA250 DAUGHTERCARD FOR DEV KIT
Other names
828-1023-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BMA250
Manufacturer:
BOSCH/博世
Quantity:
20 000
Company:
Part Number:
BMA250
Quantity:
485
Part Number:
BMA250E
Manufacturer:
AME
Quantity:
12 000
Part Number:
BMA250E
Manufacturer:
ST
0
Part Number:
BMA250E
Manufacturer:
BOSCH/博世
Quantity:
20 000
Part Number:
BMA250E(F)
Manufacturer:
ST
0
Part Number:
BMA250E(F)
Manufacturer:
BOSCH/博世
Quantity:
20 000
Part Number:
BMA250E(F)
0
Company:
Part Number:
BMA250E(F)
Quantity:
7 114
Part Number:
BMA250E-F
Manufacturer:
BOSCH/博世
Quantity:
20 000
Part Number:
BMA250EF
Manufacturer:
TE
Quantity:
30 000
Part Number:
BMA250EF
Manufacturer:
BOSCH/博世
Quantity:
20 000
5.10 Special control settings
Register (0x12) is reserved.
Register (0x13) contains settings for the configuration of the acceleration data acquisition and
the data output format.
(0x13) data_high_bw = ´0´ (´1´) selects filtered (unfiltered) acceleration data to be written into
the data registers (0x02) to (0x07). Default value of (0x13) data_high_bw is ´0´.
(0x13) shadow_dis = ´0´ (´1´) enables (disables) the shadowing procedure. Shadowing means
that the MSB register is updated by reading the corresponding LSB register. Default value of
(0x13) shadow_dis is ´0´.
Register (0x14) is the softreset register. A user-triggered reset (softreset) of the sensor is
performed after writing ´0xB6´ to the softreset register. After that reset all registers return to their
default values. Reading (0x14) softreset returns 0x00.
Register (0x15) is reserved.
5.11 Interrupt settings
Registers (0x16) and (0x17) contain the enable bits for the interrupts. Default value of each
enable bit is ´0´.
Rev. 1.0
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Table 38: Acceleration data acquisition & data output format, register (0x13)
Table 39: Interrupt setting, register (0x16)
Bit 7
(0x16) Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
data_high
_bw
Bit 6
shadow
Name
flat_en
orient_en
s_tap_en
d_tap_en
- reserved -
slope_en_z
slope_en_y
slope_en_x
_dis
Bit 5
reserved
Description
´1´ (´0´) enables (disables) flat interrupt
´1´ (´0´) enables (disables) orientation interrupt
´1´ (´0´) enables (disables) single tap interrupt
´1´ (´0´) enables (disables) double tap interrupt
reserved
´1´ (´0´) enables (disables) slope interrupt for z-axis
´1´ (´0´) enables (disables) slope interrupt for y-axis
´1´ (´0´) enables (disables) slope interrupt for x-axis
Page 42 / not for publishing
Bit 4
reserved
Data sheet
BMA250
Bit 3
reserved
Bit 2
reserved
Bit 1
reserved
Bosch Sensortec
03 March 2011
Bit 0
reserved

Related parts for BMA250