HASS 300-S LEM USA Inc, HASS 300-S Datasheet

SENSOR CURRENT 300A 5V MOD

HASS 300-S

Manufacturer Part Number
HASS 300-S
Description
SENSOR CURRENT 300A 5V MOD
Manufacturer
LEM USA Inc
Series
HASSr
Datasheet

Specifications of HASS 300-S

Current - Sensing
300A
Accuracy
±1%
Sensitivity
-
Current - Supply
22mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
5V
Output
-
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1065
Current Transducer HASS 50..600-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Primary nominal
V
G
V
R
R
C
V
I
X
ε
TCV
TCV
TCV
TCG
V
V
t
t
di/dt
V
BW
Notes:
110512/12
C
ra
r
OUT
REF
C
L
OE
OM
no
L
OUT
L
current rms
TH
Electrical data
Accuracy - Dynamic performance data
OE
I
OE
REF
50
100
200
300
400
500
600
PN
/V
(A)
REF
Temperature coefficient of V
Analog Output voltage @ I
Theoretical sensitivity
Reference voltage
Load resistance
Output internal resistance
Capacitive loading (± 20 %)
Supply voltage (± 5 %)
Current consumption @ V
Accuracy
Linearity error
Temperature coefficient of V
Temperature coefficient of V
Temperature coefficient of G
Electrical offset voltage @ I
Magnetic offset voltage @ I
after an overload of I
Reaction time to 10 % of I
Response time to 90 % of I
di/dt accurately followed
Output voltage noise
Frequency bandwidth (- 3 dB)
1)
between 1.5V - 2.8V providing its ability to sink or source approximately 5 mA.
2)
3)
4)
It is possible to overdrive V
Maximum supply voltage (not operating) < 6.5 V
Excluding Offset and Magnetic offset voltage
Small signal only to avoid excessive heatings of the magnetic core.
3)
@ I
measuring range
Primary current
PN
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
, T
± 150
± 300
± 600
± 900
± 900
± 900
± 900
I
PM
1)
A
PM
(A)
= 25°C
Ouput voltage
Ouput impedance
Load impedance
2)
0 .. I
0 .. I
(DC .. 10 kHz)
(DC .. 1 MHz)
REF
PN
P
PN
P
P
C
PN
PM
with an external reference voltage
OE
REF
OE
step
= 0, T
= 0
= 5V
step
/V
4)
REF
A
(+25.. +85°C)
(-40.. +25°C)
(+25.. +85°C)
(-40.. +25°C)
= 25°C
All Data are given with a R
HASS 50-S
HASS 100-S
HASS 200-S
HASS 300-S
HASS 400-S
HASS 500-S
HASS 600-S
Type
V
0.625
2.5 ± 0.025
typ. 200
≥ 200
≥ 2
< 5
= 4.7
5
19
≤ ± 1
≤ ± 0.5
≤ ± 1
≤ ± 0.4
≤ ± 0.525
≤ ± 0.01
≤ ± 0.015
≤ ± 0.15
≤ ±0.05% of reading//K
V
< ± 0.4
< 3
< 5
> 100
< 20
< 40
DC .. 50 kHz8: 1997
OE
REF
± (0.625. I
± 0.025
L
P
/ I
= 10 kΩ
mVpp
mVpp
mV/K
mV/K
mV/K
V/ I
PN
A/µs
%/K
%/K
mA
) V
kΩ
nF
µs
µs
%
%
%
%
PN
V
V
V
I
Features
● Hall effect measuring principle
● Galvanic isolation between
● Isolation test voltage 3300 V
● Low power consumption
● Single power supply + 5 V
● Fixed offset & Gain
● Isolated plastic case recognized
Advantages
● Easy installation
● Small size and space saving
● Only one design for wide current
● High immunity to external
● Internal & external reference.
Applications
● AC variable speed drives
● Static converters for DC motor
● Battery supplied applications
● Uninterruptible Power Supplies
● Switched Mode Power Supplies
● Power supplies for welding
Application domain
● Industrial.
PN
primary and secondary circuit
according to UL 94-V0.
ratings range
interference
drives
(UPS)
(SMPS)
applications.
= 50 .. 600 A
www.lem.com
Page 1/3

Related parts for HASS 300-S

HASS 300-S Summary of contents

Page 1

... Small signal only to avoid excessive heatings of the magnetic core. 4) 110512/12 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. All Data are given with a R Type HASS 50-S HASS 100-S HASS 200-S HASS 300-S HASS 400-S HASS 500-S HASS 600-S V ± (0.625 0.625 2.5 ± ...

Page 2

... Current Transducer HASS 50..600-S General data T Ambient operating temperature A T Ambient storage temperature S m Mass Standards Isolation characteristics V Rated isolation voltage rms with following conditions b -Over voltage category Ⅲ -Pollution degree 2 -Heterogeneous field V Rms voltage for AC isolation test, 50 Hz, 1 min d V Partial discharge extinction voltage rms @ 10 pC ...

Page 3

... General tolerance ● Aperture for primary conductor ● Transducer fastening ● Recommended fastening torque <1.5N ・ m ● Connection of secondary Remarks ● Arrow indicates positive current flow direction. ● Temperature of the primary conductor should not exceed 100°C. ± 0.5 mm 20.4x10.4x0.5mm M4 ...